Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-7-21 uJul. 24. 2006 3: 13PM r\. No. 0842 P. 8 c3 flngineering K & A Engineering, Inc. 3327 Roanoke Ave., Eugene, OR 97408 (541) 684-9399 Voice (541) 684-9358 FAX July 21, 2006 Hayden Enterprises, Inc. 2464 SW Glacier Drive #110 Redmond, OR 97756 Subject: Spnngfield Building Permn LDP2006-00093 1499 S. 58th Street - Lot #168 Inspection of Foundation Fill Project 151.06 At your request, we have inspected the in-place density of granular fills place on the subject foundation pad. The fill consists of 4 to 12-inches of 11h-inch minus dense graded crushed aggregate from Morse Bras, quany in Springfield, Oregon. We inspected the foundation pad excavation, prior placement of the granular fills, Foundation pad excavation was made according to our recommendations and involved stripPing and removing 1 to 3-feet of loose organic silts and highly plastic sitts from the foundation area. The subgrade was leveled on undisturbed native tan/brown stiff siRs over which the granular fills were placed in 12-inch maximum lifts and compacted using a vibratory steel wheeled roller. According to Durfield-testing1 we have determined that the average dry density equals or exceeds an acceptable percentage of the maximum as detennlned by ASTM 0698. A copy of the field test resuns is attached to this report. We recommend approval of the foundation fill, as constructed, by the building official. Thank you for the opportunIty to be of service. Please call us it you have questions or need further assistance. Respectfully, ~~ Michael Remboldt, P ,E. Principle, K & A Engineering, Inc. EXPIRES /~/v~ 1 Soil or aggregate density according to ADTM 02922 and water content according to ASTM 03017 J u 1. 24. 2006 3: 13 PM No. 0842 P. 9 . ~ Density of Soil and Soil-Aggregates In-Place ASTM 02922 and D3017 Project: 151.06 Site Address: 1499 S. 5atll Street - Lot # 168 Permit No: I LDP2006-00093 Date: 7/21/2006 Density Test Typel: DT - 4 Operator. 58 Material Type: 11/2" (-) from Morse Bros. Maximum Dry Denstly, pcf 144.0 Standardization and Reference Check A Density (Standard Deviations) (S,D.) 0.25 ~ Moisture, (8,D:) 1.66 Moist Dry Density, DensBy, Water Compaction, Test No. pel pet Content, % % Remarks 1 142.7 134.7 5.9 93.5% 4" I 2 1434 135.9 5.5, 944% 4" 3 1398 130.8 6.3 90.8% 4" 4 143,41 136.1 5.3 94.5% 4" I I -- I I I - I n I I I -, I I "---'1 I I I I I I I j 1 I I I I I 1 I -'1 I 1 j I ---I I -- I I I 1 I I I J 1 I I I I ] Average. 93.3% Std, Dav : 1.71% 1 Direct Transmission (DT) (specify depth, in.) or Air Gap Backscatter (AGB) (speclfly(T}ouchable or (U)ntouchable mode Test performed using Seaman Nuclear Corp model C-300, SN 21113 Client Hayden Enterprises Project: 151.06 K & A Engineering, Inc.