Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2005-1-24 .~ P;l-..r"-'''. January 24, 2005 .. Cascade Door & Window POBox 22654 Eugene, Oregon 97402 " Re 756 S 48th St _ Sorinclield Pmt COM 2004 - 01581 Job #04334-2 As you requested 1 performed a site soils mspect\On on January 20, 2005 at the above noted locatIon DUrIng that mspect\On I made the following observations The natIve soil fine fractIon is a silty clay loam of moderate denSIty More then Yz the materIal wIll pass a #200 sieve See the attached site analysIs from GeoScience Dated August 6, 2003 The site is cut so that It follows the native grade and covered with 3/4 inch minus crushed quarry rock placed in three-inch lifts The fimshed depth of the fill is approximately 18 - 24 inches in depth The crushed rock was compacted with a vibratory roller Drainage for the gravel pad was installed per my recommendations at the tIme of my inspection The fill as prepared is adequate to support a single-famIly residence with the foundatIon deSIgn pressures at the bottom of the footll1gs to have a maxImum pressure of 1500 PSF Thank you for thIS opportunity to be of service. If you have any questIOns please don't heSItate to call me at (541) 688-3020 Very truly yours - ' Owen Grover P E /' '\...~