Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1999-9-16 lp~;l Information ~ ,,"J'~~ee:~c;T?u~;:~l~sll~ DAILY FIELD REPORT Date: Client: September 16, 1999 Mr John Walchli 3306 Lynx Hollow Road Eugene, Oregon 97426 Report Number: 722-90360-1 Project Name: Duplex Project Location: 490 North 24th Street Spnngfield, Oregon P.O. No.: nla Type of Inspection: Epoxy Anchors Permit No.: Weather: 98-1075 Overcast Field Observatioll1s and Comments Performed continuous inspection dunng installation of 5/8" all thread epoxy anchored bolts In the following locations.' Hold down anchors at east sIde of east garage door, duplex addition Prior to installatIOn the prednlled holes were cleaned by nylon brush and compressed air Venfled minimum embeddment depth of 6". The above listed epoxy anchors were Installed using Simpson Strong Tie In accordance with manufacturer's directions Contractor stated nuts would be tightened after the epoxy has cured. Contractor was asked to notify our office when additional services are needed .,J~ I Inspector: D. Thornton - ICBO# 1035237-88 If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649 Respectfully Submitted, (( J. A-Ufl~'itJ(/) Raymond V. AJiperti, CS Dept Manager Spnngfleld Branch c. City of Spnngfleld THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED . \-" Professional Service Industnes, Inc' 1040A Shelley St . Spnngfleld, OR 97477' Phone 541/746-9649' Fax 541/746,7163 ~ ~- --~-~ // , ,