HomeMy WebLinkAboutPermit Correspondence 2003-8-18 1 ---_., .J FIBER GLASS BLOWING INSULATION BATTS AND BLANKETS When Installed In accordance with the man ufllcturer's recommendations, Knauf batts and blankets will provide the full R value I , MINIMUM Il-VALUE* THICKNESS To obtain an Install~d insulation insulation r~sistanc~ should not b~ (Ill of: I~ss than: R 38 R 30HD R 30 R 26 R22 R 21HD R 19 R 15HD R13 R 11 R 8 1200" 8 25" 1000" 9 00" 6 50" 5 50" 6 25"** 3 50" 3 50" 3 50" 2 50" Bag We,ght-Nomlnal28 Ibs M'mmum 27 Ibs **R 18 In aSS cav,ty (onforms to ASTM (665 and Federal SpeCIfICation HH I 521F EQUIPMENT REQUIRED 'NRlt , "This is my insulation:'@ , THERMAL PERFORMANCE (ATTIC APPLICATION) The stated thermal resistance (R value) IS provided by installing In accordance with the manufacturer's instructions, the required number of bags per 1,000 sq ft of net area, at not less than the labeled minimum thickness Failure to Install both the required number of bags and at least the minimum thickness will result In lower insulation R value Il-VALUE* To obtain an insulation r~sistanc~ (Il-valu~l of: R 50 R 44 R 38 R 30 R 26 R 22 R 19 R13 Rll 378 26 5 SF 1 058 Ibs 310 32 2 SF 869lbs 269 37 2 SF 7531bs 229 43 6 SF 6421bs 179 55 9 SF 501 lbs 155 64 6 SF 433 lbs 127 78 4 SF 357lbs 925" 109 92 0 SF 3041bs 800" 76 131 6 SF 213 lbs 575" 62 161 3 SF 174lbs 475" Th,s product conforms to the performance reqUirements of ASTM ( 764 Type I and cancelled Federal SpeCIficatIOn HH 11030B Type I, (lass B R values are determined In accordance With (687 and ( 518 * R' means resistance to heat flow The h'gher the R value the greater the insulating power Ask your seller for the fact sheet on R values To achieve labeled R vall'e, this product must be applied With a pneumatic blow ng machine and a corrug..ted hose With a minimum 25" Internal corrugation, a nrnlmum length of 150 ft and a diameter of at least 3" COils In the hose should not be less than 36" In diameter Acceptable matenal feed rate IS 5 35 lbs /mlnute Recommended feed rate IS 15 251bs /mlnute BUILDER'S INSULATION STATEMENT Batts and/or blankets have been Installed In conformance With the above recom mendatlOns to proVide a thermal resistance of R-Villu~ Th ickn~ss AttiC Area R If c; at Z.Olnches Sloped Ceilings R at Inches Walls R 7_/ at , Inches Floors (over an unheated crawl space) R ~O at I 0 Inches Crawl Space Pen meter R at Inches Date Installed g'"-/8-o .3 Blown insulation has been Installed In conformance With the above L/07~ recommendations to provide an R value of R ( uSing "'Z- J bags of this insulation to cover / 7 ~square feet of area at a minimum thickness of 2- 0 Inches _ J A. ,,- ~~p~ Ign,ture) .~ I"' -L _ b. v.7.-rY1o c_ Dt1 I ;- J , "- InSUlatIOn Contractor 0"_ Company Home BUilder (signature) ~ Company ., AC 08 5/02 Date FRAMING ADJUSTMENT To compensate for framing members, the number of bags per 1,000 sq ft of area to be Insulated should be as shown below I )OIST Il-VALUE DIMENSIONS , R 60 2x6 2x8 2x4 R 50 2x6 2x8 2x4 R 44 2x6 2x8 2x4 R 38 2x6 2x8 2x4 R 30 2x6 2x8 2x4 R 26 2x6 2x8 2x4 R 22 2x6 2x8 2x4 R 19 2x6 2x8 2x4 R13 2x6 2x8 2x4 R11 2x6 2x8 IAGS/MSF 1'" O.c. FIlAMING IAGS/MSF 24" O.c. FIlAMING 372 368 365 305 302 298 263 260 257 224 221 218 174 171 168 150 147 144 123 120 117 104 101 98 71 68 66 57 55 52 373 371 368 306 304 302 265 263 260 225 223 221 175 173 171 151 149 147 124 122 120 105 103 101 73 71 69 59 57 55 CLOSED-CAVITY APPLICATION (EXTERIOR SIDEWALL OR FLOORfD Date 1: Contact Knauf Fiber Glass for more informatIOn /" Knauf Fiber Glass, One Knauf Dnve, ShelbYVllle, IN 46176 (800) 825 4434 ATTICS) ~ Pnnted In USA