Loading...
HomeMy WebLinkAboutPermit Correspondence 2003-9-25 \5 ~s s. ~l~f-_ i~, ( ~' FIBER GLASS BLOWING INSULATION I I I , , , ,- , , ~ , , kN.y ~~O, ~ ~ '*" o ~, :r w ...-. * ,1 (,/"l ""t ? 'fe \~~! $ . . my insulation:' "This IS , , , , I I ~ BATTS AND BLANKETS THERMAL PERFORMANCE (ATTIC APPLICATION) When Installed In accordance with the man ufacturer's recommendations, Knauf batts and blankets will provide the full R value The stated thermal resistance (R value) IS provided by installing In accordance with the manufacturer's instructions, the required number of bags per 1,000 sq ft of net area, at not less than the labeled minimum thickness Failure to Install both the required number of bags and at least the minimum thickness will result In lower insulation R value MINIMUM ~.VALUE* THICKNESS To obtain an Installed insulation insulation resistance should not be (~) of: less than:" ~-VALUE* To obtain an insulation resistance (~.value) of: R 38 1200" R 30HD 825" R30 1000" R 26 900" R 22 650" R 21HD 550" R 19 6 25"** R 15HD 350" R13 350" R11 350" R8 250" R 50 R 44 R 38 R 30 R 26 R22 R 19 R13 R11 378 26 5 SF 1 058 Ibs 2350" 310 32 2 SF 8691bs 2000" 269 37 2 SF 7531bs; 1775" 229 43 6 SF 6421bs 1550" 179 559 SF 501 Ibs 1250" 155 64 6 SF 433 Ibs 11 00" 127 78 4 SF 3571bs 925" 109 92 0 SF 3041bs 800" 76 131 6 SF 213 Ibs 575" 6 2 161 3 SF 174lbs 475" Bag We,ght-Nomlnal 28 Ibs , M,mmum 27 lbs **R 18 In a 5 5 cav,ty (onforms to ASTM (665 and Federal SpeCificatIOn HH I 521F Th,s product conforms to the performance requirements of ASTM ( 764 Type I, and cancelled Federal Spec,ficat,on HH 11030B Type I, (lass B R values are determined In accordance With (687 and ( 518 * R' means reSistance to heat flow The h'gher the R value the greater the insulating power Ask your seller for the fact sheet on R values EQUIPMENT REQUIRED To achieve labeled R vall'e, thiS product must be applied With a pneumatic blow Ing machine and a corrug~ted hose With a minimum 25" Internal corrugation, a TIlnlmum length of 150 ft and a diameter of at least 3" COils In the hose should not be less than 36" In diameter Acceptable material feed rate IS 5 35 Ibs {minute Recommehded feed rate IS 1525 Ibs {minute \ BUILDER'S INSULATION STATEMENT Batts and{or blankets have been Installed In conformance With the above recom mendatlOns to prOVide a thermal resistance of R-Villue Thickness Attic Area R tJ9 at zP Inches Sloped Ceilings R at Inches Walls R 2-1 at 6 Inches Floors (over an unheated crawl space) R < C) at JOlnches Crawl Space Perimeter R at Inches Date Installed 7- 7__~- 015 . Blown insulation has been Installed In conformance With the above recommztlons to prOVide an R value of R (-I Y uSing '3 bags of thiS insulation to cover l / ~ f... square feet of area at a minimum thickness of Z-C/ Inches .....", ~ ~~;) 1"p/~~re;1 Co/A-:-t Date In","latlOn tontra(to~~ c--J.R - b~ Company /~f Home Budder (signature) , ~ Company Date BW AC DB 5{02 FRAMING ADjUSTMENT To compensate for framing members, the number of bags per 1,000 sq ft of area to be Insulated should be as shown below I I JOIST ~.VALUE DIMENSIONS I IAGS{MSF W' O.c. F~AMING IAGS{MSF 24" O.c. F~AMING 372 368 365 305 302 298 263 260 257 224 221 218 174 171 168 150 147 144 123 120 11 7 104 101 98 71 68 66 57 5 5 52 373 371 368 306 304 302 265 263 260 22 5 223 221 175 173 171 151 149 147 124 122 120 105 103 101 73 71 69 59 57 55 R 60 2x6 2x8 2x4 R 50 2x6 2x8 2x4 R 44 2x6 2x8 2x4 R 38 2x6 2x8 2x4 R 30 2x6 2x8 2x4 R 26 2x6 2x8 2x4 R 22 2x6 2x8 2x4 R 19 2x6 2x8 2x4 R13 2x6 2x8 2x4 R-ll 2x6 2x8 CLOSED-CAVITY APPLICATION (EXTERIOR SIDEWALL OR FLOORED ATTICS) ,I , Contact Knauf Fiber Glass for more information l'/ Knauf Fiber Glass, One Knauf Drive, Shelbyville, IN 46176 (BOO) 825 4434 Printed In USA