Loading...
HomeMy WebLinkAboutPermit Correspondence 2003-7-23 lw~" ~ ~~rr t~~~1~~d ~ Builders Statement fJ1.R;J!J CcJ/IA.A. Hozw;;;;el;slteNam/1 ~/f~ ~ .~l2~~AtP4~~~~~,,,~~? BUilder (sign) Inspected By (sign If required) - .......<"'f I R-VALUE ) To obtain a 'i Thermal ReSlstance-"-Q (R) of 60 49 44 38 30 26 22 19 13 11 BAGS PER 1000 SQ FT Bags per 1000 sq ft of net area 365 296 264 (228 180 155 131 111 77 66 R-VALUE CEILINGS c.;-CJ trfY~ WAllS FLOORS InsulSafe@4 Fiber Glass Blowing Insulation Company Name Date Date MAXIMUM SQ FT PER BAG Contents of bag should not cover more than (sq It) 27 34 38 44 56 65 76 90 129 151 MINIMUM WEIGHT- POUNDS PER SQ FT Weight per sq It of Installed insulation should not be less than (Ibs) 0986 0800 0712 0615 0485 o 41B 0353 0301 0209 0179 .......... MINIMUM THICKNESS Should not be less than (In) 22 18V, 16'/, 14% 12 1OV, 9 7% 5V, 4% THICKNESS AREA (SQ FT) BATTS/ROllS (01) INSUlSAFE 4 (01) ./ BAGS USED rf>/~ l/' /rP THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must Install the minimum number of bags per 1,000 sq ft of net area for each R-Value listed . The maximum net coverage must 'not exceed that speCified for each R-Value . The Installed Insulation must be at or above the sp~clfled:mlnlmUm thickness for eaC'h R-Value Failure to Install the required minimum weight per sq ft of Insulation at or above the minimum thickness Will result In reduced R-Value . . This product should not be mixed with other blown Insulations or the thermal claims Will become invalid. " DANGER RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF L SUCH DEVICES DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS 30-24-233 BUilders Statement A Saint Gobaln Company @2002 CertalnTeed Corporation 11/02 Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@4 Fiber Glass Blowing Insulation ~@[f~@lBrr1lY@@d ~ CertalnTeed Corporation PO Box 860 Valley Forge, PA 19482 THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW The following thermal performances are achieved at weights and coverages specified when insulation IS Installed with pneumatic equipment In a hOrizontal open blow application BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM R VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT TH ICKN ESS To obtain a Bags per Contents of bag Weight per sq ft of Shou Id not be Thermal ReSIStance 1000 sq ft shou Id not cover Installed insulation should less than (R) of of net area more than (sq ft) not be less than (Ibs) (In ) 60 365 27 0986 I;--~ - 22 h- 49 296 34 0800 18'(, I, 44 264 38 0712 r~, 16% 38 228 44 0615 I - '~14% 30 180 56 0485 I 12 26 155 65 0418 I 10'(, 22 131 76 0353 I 9 19 111 90 0301 I 7% 13 77 129 0209 I 5'(, 11 66 151 0179 I 43/4 R-values are determined In accordance with ASTM C 687 and C 518 Compiles with ASTM C 764 as Type 1 insulation THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION When Installed With pneumatic equipment In Sidewalls, the follOWing thermal performances are achieved at the thicknesses, weights and coverages specified BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM R VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS To obtain a Bags per Contents of bag Weight per sq ft of Should not be Thermal ReSistance 1000 sq ft should not cover ,nstalled Insulat,on should less than (R) of of net area more than (sq ft) not be less than (Ibs) (In ) 29 358 28 0967 7'/4 22 272 37 0733 5'(, 16 198 51 0533 4 15 179 56 0484 3% ;<1' 14 173 58 0467 3'(, READ THIS BEFORE YOU BUY What.:-you should know about R-Values f The chart shows the R-Value of thiS Insulation R means resistance to heat flow The higher the R- Value, the greater the Insulating power Compare Insulation R-Values before you buy There are other factors to consider The amount of Insulation you need depends mainly on the climate you live In Also, your fuel savings from Insulation Will depend upon the climate, the type and size of your house, the amount of Insulation already In your house, and your fuel use patterns and family size If you buy too much Insulation, It Will cost you more than what you'll save on fuel To get the marked R-Value, It IS essential that thiS Insulation be Installed properly '~"\ ~ 4" \ \1 r ....."'"'C.J -'" ...-., ~ Jl. ...'..1'"... ,- , ....~\,. ~ "\-..... ~ ~~ ",'" ... .'k.j- L