HomeMy WebLinkAboutPermit Correspondence 2003-8-13
=--
o
;
(C~~'rCIDJfl1:~~({f Mii
~ '\
Builders Statement '- ~
/'
0.-0.
BUilder (sign)
//'/
....-
Inspected By (sign If reqUired)
<7~
... ,,-,....
"'. "'"
o
q ~v./
.
~
BAGS PER
1000 sa FT
Bags per
1000 sq It
of net area
365
296
264
228
180
.155
<7 131
111
77
66
<<:>
MAXIMUM
Sa FT PER BAG
R-VALUE
To obtain a
c> Thermal Resistance
(R) of
60
49
44
38
30
26
22
19
13
11
c:~
..
.... Contents of bag
should not cover
more than (sq It)
27
34
38
44
56
65
76
90
129
151
o
\-
R-VALUE
THICKNESS
"
C'>
Ilf'/&
~9
~") CEILINGS
WALLS
FLOORS
(~J
<)
/
..
<>
G
Co
o
o
o
(.. " .."
-,'" ...-).. .~
''\
Company Name
~
"."
'" ,
AREA (Sa FT)
tlC?e
<>
4(>
'....
f!1~3
./ Date
0--
"
~
InsulSafe@4
Fiber Glass Blowing Insulation
-
1L1~ V~~c
HO~9i~ JObSI!;me ~ ~ . -
-=$~~ ~/J?, ~ P4j~
,,,"",, ""~ ("go) 7 · /{l/ ~ ~... C,moro, N,me
~THERMAL PERFORMANCE-ATTIC BLOWING APPLlCATION/ I
~ .-<'/
" .,In accordal]ce with the-chart above, you must Install the minimum number of bags per 1,000 sq ft of net area for each
R-Value listed Q ":,.<;:1/ ...
, ~
The maximum net coverage must not exceed that specified for eglEh R-Value
o 0 ~,A
. The Installed Insulation must be at or above the specified minimum thickness for each R-Value \
. <faIlure to Install the reqUired minimum weight per sq':ft of insulation at or aBove the minimum thickness will result In
reduced R-Value a
. This product should not be ml:e~d ~ other blown Insulatlons!~r the thermal claims will become Invalid ~
.r :~,~ ' .....!
<:;.f ~/), ~ ~ ~?~ ; \.
DANGER RECESSED LIGHT FIXTWRES-TO, PREVENT OVERHEATING, DO NOHNSUlATE ON TOP OR,WITHIN 3" OF
- SUCH DEVICES DOES NOT APP~Y~TO TYPE IC LIGHT FIXTUREScOR TO FLUORESCENT FIXTURES WITH
THERMAl~Y'PROTECTED 8AllAST~ ~,,~ <> ~ 0
~ -- ~-
30 24-233 BUilders Statement _=_ ': A Salnt-Gobaln Company @2002j3'e-rtaInTeed Corporation 11/02
o j\ G - l
~ '\.. <j
Date
c,
c::, MINIMUM WEIGHT-
POUNDS PER sa FT
Weight per sq It of
Installed insulation should
not be less than (Ibs)
0986
0800
0712
0615
0485
0418
0353
0301
0209
0179
~
I
I
I
I
I
I
I'"
MINIMUM
THICKNESS
Should not be
less than
(in)
22
18Y,
16%
14%
12
10'/,
9
7%
5Y,
4%
()
INSULSAFE 4 (~l;
t/'
I B~GS USED
I~&
'I 0:
I
I
I
I
BATTS/ROLLS (II)
I, ...
~r.
""
~
c
.'
!
"
-}
\
Manufacturer Insulation Fact Sheet \
This is CertainTeed Corporation InsulSafe@ ~I
Fiber Glass Blowing Insulation
(Ce~~a18n1r~ed [S]
........
Certal n Teed Corporation
PO Box 860
Valley Forge, PA 19482
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages speCified when insulation IS Installed with
pneumatic equipment In a hOrizontal open blow application
BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM
R VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS
To obtain a Bags per Contents of bag WeIght per sq ft of Should not be
Thermal ReSIStance 1000 sq ft should not cover Installed Insulat,on should less than
(R) 01 of net area more than (sq ft) not be less than (Ibs) (In )
-~ -" 60 365 27 0986 22
49 296 34 0800 18'12
44 264 38- 0712 16%
38' 228 44 0615 14%
30 180 56 0485 12
26 155 65 0418 10'12
22 131 76 0353 9
19 111 90 0301 7%
13 77 129 0209 5'12
11 66 151 0179 4%
R-values are determined In accordance with ASTM C 687 and C 518 Compiles with ASTM C 764 as Type 1 insulation
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When Installed with pneumatic equipment In sidewalls, the following thermal performances are achieved at the
thicknesses, weights and coverages speCified
BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM
R VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS
To obtain a Bags per Contents of bag Weight per sq It of Should not be
Thermal ReSIStance 1000 sq ft shou Id not cover Installed insulation should less than
(R) of 01 net area more than (sq It) not be less than (Ibs) (In )
/
29 358 28 0967 7'/4
22 272 37 0733 5'12
16 198 51 0533 4
15 179 56 0484 3%
14 173 58 0467 3'12
READ THIS BEFORE YOU BUY
What you should know about R-Values
The chart shows the R-Value of thiS insulation R means resistance to heat flow The higher the R-
Value, the greater the Insulating power Compare Insulation R-Values before you buy
There are other factors to consider The amount of Insulation you ~~d depends mainly on the
climate you live In Also, your fuel savings from Insulation Will d5lr~o"'upOQ the climate, the type
and size of your house, the amount of Insulation already In yo]jr hOLJ~e, and'~/..Qur fuel use
patterns and family size If you buy too much Insulation, It WII', cost you more Hl8.n what you'll
save on fuel (' \,
To get the marked R-Value, It IS essential that thiS Insulation be Installed properly
l ~