Loading...
HomeMy WebLinkAboutPermit Correspondence 2003-10-29 \ro^J ~li ~ FIBER GLASS BLOWING INSULATION BATTS AND BLANKETS When Installed In accordance with the man ufacturer's recommendations, Knauf batts and blankets Will provide the full R value MINIMUM ~-VALUE* THICKNESS To obtain an Install~d insulation insulation r~sistanc~ should not b~ (~) of: l~ss than: R 38 R 30HD R 30 R 26 R 22 R 21HD R 19 R 15HD R13 Rll R8 1200" 8 25" 1000" 9 00" 6 50" 5 50" 6 25"** 3 50" 3 50" 3 50" 2 50" Bag We,ght-Nomlnal 28 lbs MIn,mum 27 Ibs **R 18 In a 5 5 cavity (onforms to ASTM ( 665 and Federal Spec,flCat,on HH I 521F EQUIPMENT REQUIRED THERMAL PERFORMANCE (ATTIC APPLICATION) The stated thermal resistance (R value) IS provided by installing In accordance with the manufacturer's instructions, the required number of bags per 1,000 sq ft of net area, at not less than the labeled minimum thickness Failure to Install both the required number of bags and at least the minimum thickness Will result In lower insulation R value ~-VALUE* To obtain an insulation r~sistan(~ (~-valu~) of: I MAXIMUM NET COVE~AGE cont~ntsthis ba!: should (ov~r mor an: lAGS ~E~ 1,000 SQ. FT. Th~ numb~r of ba!:s p~r' 1,boo sq. ft. of n~t ar~a should not b~ l~ss than: R 50 R 44 ,- R 38 - R 30 R 26 R 22 R 19 R13 Rll MINIMUM WEIGHT ~E~SQ. FT. Th~ w~i!:ht p~r sq. ft. of install~d insulation should not b~ l~ss than: MINIMUM THICKNESS Install~d insulation should not b~ l~ss than: I III " To achieve labeled R value, thiS product must be applied with a pneumatic blow ~g machine and a corrugated hose with a minimum 25" Internal corrugation, a lInlmum length of 150 ft and a diameter of at least 3" COils In the hose should not be less than 36" In diameter Acceptable material feed rate IS 5 35 Ibs /mlnute Recommended feed rate IS 1525 lbs /mlnute 378 26 5 SF 1 058 lbs 310 32 2 SF 869 Ibs 269 372 SF 753lbs 229 43 6 SF 642 lbs 179 559 SF 501 lbs 155 64 6 SF 433 lbs 127 78 4 SF 357lbs 109 92 0 SF 304lbs 800" 7 6 131 6 SF 213 lbs 575" 6 2 161 3 SF 174 lbs 475" II ThiS product conforms to the performance requirements of ASTM ( 764, Type I, and cancelled Federal SpeCifICation HH 11030B Type I (lass B R values are determined In accordance with (687 and ( 518 * R means res,stance to heat flow The h'gher the R value the greater the insulating power Ask your seller for the fact sheet on R values BUILDER'S INSULATION STATEMENT Batts and/or blankets have been Installed In conformance with the above recom mendatlons to prOVide a thermal resistance of R.Value Thickness AttiC Area R l-! CJ at Z.Olnches Sloped Ceilings R at Inches Walls R ~I at 6 Inches Floors (over an unheated crawl space) R "30 at / /:!!,ches Crawl Space Perimeter R at Inches Date Installed /' /J - 7 _ 9 - 0 3 Blown insulatIOn has been Installed In conformance with the above recommendations to prOVide an R value of R ~ 9 uSing '<' ~ bags of thiS Insulalion to cover / -? I '-]quare feet ot:rea:; a minimum thickness of ~ 0' In~es " ~~f7~~/~ Insulation Q~~a~slg.AA'U - / --g-~~ _ ~ /\P ./1- k/{ ~ , r 6 C:r - (omPFk-vJ~., ~""'-t r ,e' 7 """"fA "j:at HomezqrJlgna re) ~ . __ \tv..~\ (on,.ra ~~r ~ , BW AC 08 5/02 Date FRAMING ADJUSTMENT To compensate for framing members, the number of bags per 1,000 sq ft of area to be Insulated should be as shown below IJOIST IAGS/MSF IAGS/MSF ~-VALUE DIMENSIONS W' O.c. F~AMING 24" O.c. F~AMING I R 60 2x6 368 371 2x8 365 368 2x4 305 306 R 50 2x6 302 304 2x8 298 302 2x4 263 265 R 44 2x6 260 263 2x8 257 260 2x4 224 225 R 38 2x6 221 223 2x8 218 221 2x4 174 17 5 R 30 2x6 171 173 2x8 168 171 2x4 150 151 R 26 2x6 147 149 2x8 144 147 2x4 123 124 R 22 2x6 120 122 2x8 11 7 120 2x4 104 105 R 19 2x6 101 103 2x8 98 101 2x4 71 73 R13 2x6 68 71 2x8 66 69 2x4 57 59 R 11 2x6 55 57 2x8 52 5 5 CLOSED-CAVITY APPLICATION (EXTERIOR SIDEWALL OR FLOORED ATTICS) Contact Knauf Fiber Glass for more information Knauf Fiber Glass, One Knauf Drive, Shelbyvllle, IN 46176 (800) 825 4434 Printed In USA