August 1, 1997
-
J
\
.., I It
f ,
Rick Wells
r
9~420 Temtonal Road
Junction CIty, OR 97448 -
~
,
RE 69th Place & Ivv S1. Sonmmeld. OR - Comoactlon Test - W 0 #10191-BRM
<=f1'S ~I Ct,1~ 'PWe, - j - "
As you requested, a compactIOn ~mspectIon of the gravel under the proposed foundatIon has been
performed on tlus site m prepar~tIon for the constructIOn mvolvmg foundatIons for the proposed
residenCe The excavatIon mvolvep the placement of 12" llllIlll11uin of I Y2" mInus crushed rock The,
compacted surface of the crushed rock IS adequate for a foundatIon,beanng capacity of 1000 psf
The site draInage and foundatIon were not deSigned or reViewed by Mortier Engmeenng, P C The
compactIOn of the gravel surface IS gr~ter than 95% of a stan~ard proctor, per ASTM D698-91
(See attached data sheets) , :
I hope you find tlus rep.ort' adeq~ate for your needs and purposes'~t tlus tune Thank you for tlus
opporturuty to be of servIce ' Please contact me If you have further questions at 484-9080