HomeMy WebLinkAboutPermit Correspondence 2003-12-20 FIBER GLASS BLOWING INSULATION BATTS AND BLANKETS When Installed In accordance with the man ufacturer's recommendations, Knauf batts and blankets will provide the full R value MINIMUM ~-VALUE* THICKNESS To obtain an Installed insulation insulation resistance should not be (~) of: less than: R 38 R 30HD R 30 R 26 R22 R 21HD R 19 R 15HD R13 R 11 R 8 1200" 8 25" 1000" 9 00" 6 50" 5 50" 6 25"** 3 50" 3 50" 3 50" 2 50" Bag Weight-Nominal 28 Ibs MIn,mum 27 Ibs **R 18 In a 5 5 cav,ty Conforms to ASTM C 665 and Federal Spec,f,cat,on HH I 521F r 1 . _I 1 ... t 1 "~ I~~ ". 1 " THERMAL PERFORMANCE (ATTIC APPLICATION) The stated thermal resistance (R value) IS provided by installing In accordance with the manufacturer's instructions, the required number of bags per 1,000 sq ft of net area, at not less than the labeled minimum thickness Failure to Install both the required number of bags and at least the minimum thickness will result In 10wJ!r insulation R value ~-VALUE* To obtain an insulation resistance (~-value) of: lAGS ,"E~ 1,000 SQ. FT. The number of ba~s per 1,000 sq. ft. of net area should not be less than: R 50 R 44 R 38 R 30 R 26 R22 R 19 R13 Rll 378 26 5 SF 1 058 Ibs 2350" 310 32 2 SF 8691bs 2000" 269 37 2 SF 753 Ibs 1775" 229 43 6 SF 642 Ibs 1550" 179 55 9 SF 501 Ibs 1250" 15 5 64 6 SF 4331bs 1100" 127 78 4 SF 3571bs 925" 109 92 0 SF 3041bs 800" 76 131 6 SF 213 Ibs 575" 6 2 161 3 SF 174 Ibs 475" ThiS product conforms to the performance requrrements of ASTM C 764 Type I and cancelled Federal Speclf,cat,on HH 11030B Type I Class B R values are determined In accordance with C 687 and C 518 * R means res,stance to heat flow The h'gher the R value the greater the insulating power Ask your seller for the fact sheet on R values EQUIPMENT REQUIRED To achieve labeled R value, thiS product must be applied with a pneumatic blow ng machine and a corrugated hose with a minimum 25" Internal corrugation, a n1mmum length of 150 ft and a diameter of at least 3" Colis In the hose should not be less than 36" In diameter Acceptable matellal feed rate IS 5 35 Ibs /mlnute Recommended feed rate IS 15 251bs /mlnute BUILDER'S INSULATION STATEMENT Batts and/or blankets have been Installed In conformance with the above recom mendatlons to prOVide a thermal resistance of R-Villue Thickness Attic Area Sloped Ceilings Walls Crawl Space Pellmeter Floors (over an unheated crawl space) R '19 at z.Qnches R at Inches R 7-( at 6 Inches R 3 oat ( 61nches R at Inches Date Installed J c- ~ C3r.$" Blown insulation has been Installed In conformance with the above recommendations to prOVide an R value of R ...!:t5 uSing ~ '7 bags of this insulation to cover /00 Quare feet of area at a minimum thickness of ("~......... Inches '"";;"'~J'"''';nh~ Company , II , (. - h ' f Ho.\J r.... HOlII\.l ( - I Home BUlldlrlSlg"t07 ~ I P'" "'" 1(.. \.. l Company BW AC 08 5/02 Date Date FRAMING ADJUSTMENT To compensate for framing members, the number of bags per 1,000 sq ft of area to be Insulated should be as shown below . OIST IAGS/MSF IAGS/MSF ~-VALUE DI NSIONS a" O.c. F~AMING 24" O.c. F~AMING 2x4 372 373 R 60 2x6 368 371 2x8 365 368 2x4 305 306 R 50 2x6 302 304 2x8 298 302 2x4 263 265 R 44 2x6 260 263 2x8 257 260 2x4 224 225 R 38 2x6 221 223 2x8 218 221 2x4 174 175 R 30 2x6 171 17.3 2x8 168 171 2x4 150 151 R 26 2x6 147 149 2x8 144 147 2x4 123 124 R 22 2x6 120 122 2x8 117 120 2x4 104 105 R 19 2x6 101 103 2x8 98 101 2x4 71 73 R13 2x6 68 71 2x8 66 69 2x4 57 59 R 11 2x6 55 57 2x8 52 55 ClOSED-CAVITY APPLICATION (EXTERIOR SIDEWALL OR FLOORED ATTICS) Contact Knauf Fiber Glass for more informatIOn I Knauf Fiber Glass, One Knauf Dllve, Shelbyv,lle IN 46176 (800) 8254434 Pllnted In USA