DAILY FIELD REPORT
Date
Client:
September 15,1999
Bill Poole
W L Poole Construction
672 Anderson Lane
Spnngfleld, OR 97477
Report Number
722-90352-2
PrOject Name.
Dan Sickler ReSidence
PrOject LocatIon'
632 S 72nd, Springfield, OR
P 0 No Letter
Type of InspectIon. Weldments
Fabricator/Erector Westrock Const & Fabrication
PermIt No
Weather
FIeld or Shop
99-1133
Clear
Field
Field Observations and Comments
Performed visual inspection of completed weldments on elevated metal driveway, entry to garage Checked puddle
weldments and button punch on metal decking Welding was done With SMAW process uSing E7018 Electrode on all
structural steel components under decking The beams and tube steel columns were welded at fabncatlon shop
Without special inspection Weldments were painted at the time of inspection
,,\Ieldments were checked for Size, length, profile and location To the best of our knowledge, the work checked IS In
conformance With approved drawing, specification and applicable AWS D1 1 (Static) Code, except as noted for shop
weldments, which appear to be acceptable Contractor was asked to notify our office when additional services are
needed
Inspector C Halstead ICB01060568-85
If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649
Respectfully Submitted,
~\J /t'n ~ ,,-t,
" ~ymo~~DePt
Springfield Branch
/'
~-J
Manager
c city of Springfield
THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT BY ANY METHOD AND ITS TRANSMIITAL TO A THIRD
PARTY BY ANY MEANS EXCEPT IN FULL WITHOUT THE WRIITEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES IS PROHIBITED
"
'"'!
ProfeSSional Service Industnes Inc' 1040A Shelley St . Springfield OR 97477' Phone 541/746-9649' Fax 541/746 7163
l "'!~ ., Injormntion
~..". .To Build On
Engineering. Consulting · Testing
0::.
DAILY FIELD REPORT
Date September 7, 1999 Report Number 722-90352-1
Client WL Poole Construction Project Name Dan Sickler Residence
Bill Poole
672 Anderson Lane Project Location Spnngfleld, OR
Spnngfleld, OR 97477
PO No Letter Permit No 99-1133
,
Type of Inspection Epoxy Anchors Weather Sunny
Field Observations and Comments
Performed continuous inspection dunng the installation of 3/4" all thread epoxy anchored bolts In following locations
Lower base plates footing pad connections 8-(4) anchors each, at the garage approach Pnor to installation the
prednlled holes were cleaned by nylon brush and compressed air Venfled minimum embeddment depth of 4 Inches
The above listed epoxy anchors were Installed uSing a Epcon Ceramic 6 In accordance with the manufacturer's
directIons Contractor stated the nuts would be tightened after the epoxy has cured The epoxy anchors were Installed
In accordance with approved jobslte plans and specifications Contractor was asked to notify our office when additional
services are needed
'Inspector Brad Nehrer
If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649
\ije:~~ SUbm~,
R~ond V Aliper . CS De
Spnngfleld Branch
L~
c City of Spnngfield
/