Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1999-9-15 ...:t .,. , [("sipn!ormntion ~WI. .To Build On Engineering 0 Consulting · Testing DAILY FIELD REPORT Date Client: September 15,1999 Bill Poole W L Poole Construction 672 Anderson Lane Spnngfleld, OR 97477 Report Number 722-90352-2 PrOject Name. Dan Sickler ReSidence PrOject LocatIon' 632 S 72nd, Springfield, OR P 0 No Letter Type of InspectIon. Weldments Fabricator/Erector Westrock Const & Fabrication PermIt No Weather FIeld or Shop 99-1133 Clear Field Field Observations and Comments Performed visual inspection of completed weldments on elevated metal driveway, entry to garage Checked puddle weldments and button punch on metal decking Welding was done With SMAW process uSing E7018 Electrode on all structural steel components under decking The beams and tube steel columns were welded at fabncatlon shop Without special inspection Weldments were painted at the time of inspection ,,\Ieldments were checked for Size, length, profile and location To the best of our knowledge, the work checked IS In conformance With approved drawing, specification and applicable AWS D1 1 (Static) Code, except as noted for shop weldments, which appear to be acceptable Contractor was asked to notify our office when additional services are needed Inspector C Halstead ICB01060568-85 If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649 Respectfully Submitted, ~\J /t'n ~ ,,-t, " ~ymo~~DePt Springfield Branch /' ~-J Manager c city of Springfield THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT BY ANY METHOD AND ITS TRANSMIITAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL WITHOUT THE WRIITEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES IS PROHIBITED " '"'! ProfeSSional Service Industnes Inc' 1040A Shelley St . Springfield OR 97477' Phone 541/746-9649' Fax 541/746 7163 l "'!~ ., Injormntion ~..". .To Build On Engineering. Consulting · Testing 0::. DAILY FIELD REPORT Date September 7, 1999 Report Number 722-90352-1 Client WL Poole Construction Project Name Dan Sickler Residence Bill Poole 672 Anderson Lane Project Location Spnngfleld, OR Spnngfleld, OR 97477 PO No Letter Permit No 99-1133 , Type of Inspection Epoxy Anchors Weather Sunny Field Observations and Comments Performed continuous inspection dunng the installation of 3/4" all thread epoxy anchored bolts In following locations Lower base plates footing pad connections 8-(4) anchors each, at the garage approach Pnor to installation the prednlled holes were cleaned by nylon brush and compressed air Venfled minimum embeddment depth of 4 Inches The above listed epoxy anchors were Installed uSing a Epcon Ceramic 6 In accordance with the manufacturer's directIons Contractor stated the nuts would be tightened after the epoxy has cured The epoxy anchors were Installed In accordance with approved jobslte plans and specifications Contractor was asked to notify our office when additional services are needed 'Inspector Brad Nehrer If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649 \ije:~~ SUbm~, R~ond V Aliper . CS De Spnngfleld Branch L~ c City of Spnngfield / THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT BY ANY METHOD AND ITS TRANSMITTAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES IS PROHIBITED ~! Professional Service Industnes Inc. 1040A Shelley St. Spnngfleld OR 97477. Phone 541/746-9649. Fax 541/7467163