Builders Statement
7/ Cl7 '1) '?Ia~e
InsulSafe@4
Fiber Glass B;owing Insuation
InsulSafe@ 4 has been Installed In
accordance with the manufacturer's
r---LecommendatJOns to provide a value of
\ ~us,lng ;J.:rJ>ags of insulatIon to
\.. cover-fLl-(L square f~et of are~ at, a
~um thickness of l.s1nches
~l' "
; , /tb..110r J <
Instj~er Contr~slgn) / ;; A
-tra", ~ .J..,/V$.J!t:i:L&A ~O.
Ctypany Name n ""6/
t:f..u4 V5 LL~ f'5(:.,.(J
Data.../ /
Budder (sign)
Cpmpany Name
Date
!
J
Batts and Blankets
R-Value Insulation
Thickness (In)
38 10,12
30 I 8'/4, 10
25 I 8
.22 6~
21 I 5';'
19 I 6'/4
15 I ~ 3';'
13 I 3'/2
11 I 3'/2
Fiber glass batts or rolls have been
mstalled m accordance wIth the
manufacturer's recommendations to
provide an R-value of -:?(') m the
ceJlmg8 J m the exterior walls,~
m e floor or crawl space perimeter
. /-rnYl.
\ nstaller Contractor ~,gn) / /"
. ..J.I- K _ ., J _.. I..SJ1.M/() It lA/ ..
~,~ameQ ~()O /
Date ......, 'I'" .
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
· In accordance With the chart below, you must Install the minimum number of bags
per 1,000 sq ft of net area for each R-Value listed
· The maximum net coverage must not exceed that specified for each R-Value
· The Installed insulation must be at or above the specified minimum thickness for
each R-Value
· Failure to Install the required minimum weight per sq ft of insulation at or above
the minimum thickness will result In reduced R.Value
· ThiS product should not be mixed With other blown insulations or the thermal
claims will become Invalid
BAGS PER MAXIMUM MINIMUM WEIGHT - MINIMUM
R VALUE 1000 SQ FT . SQ FT PER BAG POU N DS PER SQ FT THICKNESS
To obtain a Bags per Contentspf bag We'ght per sq ft of Should not be
,Thermal ReSIStance 1000sq ft shou Id not cover Installed insulation should less than
(R) of of net area more than (59 ft) not be less than (Ibs) (In )
60 365 27 0986 22
49 296 34 0800 18';' I
44 264 38 0712 16% I
C 31j_ _2 , 228~ - 4C'-: 0615 14% I -
30 180 56 0485 12 I
26 155 65 0418 10';' I
22 131 77 0353 9 I
19 111 90 0301 7% I
13 77 129 0209 5';'
11 66 151 0179 4% -
.. -.
R-values are determined In accordance With ASTM C 687 and 518
Compiles With ASTM C 764 as Type 1 insulation
"R" means resIstance to heat flow The higher the R-Value, the greater the
~
insulating power To get the marked R-Value, It IS essential that the
insulation IS Installed properly
DANGER RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING,
< DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH
DEVICES DOES NOT APPLY TO TYPE IC LIGHT FIXTURES
OR TO FLUORESCENT FIXTURES WITH THERMALLY
PROTECTED BALLASTS
FRAMING ADJUSTMENT
To compensate for framing members the number of bags per 1000 sq ft
of net area should be reduced as follows
-
Budder (slgn)t JOist Size Bags to deducl/1 000 sq It Bags to deducl/1000 sq ft
(on ) JOISts 16" 0 C JOists 24" 0 C
\ .~I'
Company Name 2x4 05 03
2x6 08 05
Date 2x8 10 07
<l;' 2 x 10 1 3 09
<:
, -
Code No 30 24 233 2000 Certalneed Corporation 2/00
~
~
.
~@[f~(IDD[fiJU@@(Q] L5U
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@4
Fiber Glass Blowing Insulation
CertalnTeed Corporation
PO Box 860
Valley Forge, PA 19482
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages specified when insulation IS Installed with
pneumatic equipment In a hOrizontal open blow application
BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM
R VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS
To obtain a Bags per Contents of bag Weight per sq ft of Should not be
Thermal Resistance 1000 sq ft shou Id not cover Installed Insulat,on should less than
(R) of of net area more than (sq ft) not be less than (lbs) (In )
60 365 27 0986 22
49 296 34 0800 18'12
44 264 38 0712 16'14
38 228 44 0615 14'14
30 180 56 0485 12
26 155 65 0418 10'12
22 131 77 0353 9
19 111 90 0301 7'14
13 77 129 0209 5'12
11 66 151 0179 4'14
R-values are determined In accordance with ASTM C 687 and 518 Complies with ASTM C 764 as Type 1 insulation
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When Installed with pneumatic equipment In sidewalls, the following thermal performances are achieved at the
thicknesses, weights and coverages speCIfied .
BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM
R VALUE 1000 SQ FT SQ FT PER BA~ POUNDS PER SQ FT THICKNESS
To obtain a Bags per [ Contents of bag We'ght per sq It of Should not be
Thermal ReSIStance 1000 sq ft should not cover Installed insulation should less than
(R) of of net area more than (sq It) not be less than (lbs) (In )
29 358 28 0967 7'/4
22 272 37 0733 5'12
16 198 51 0533 4
15 179 56 0483 3%
14 173 58 0467 3';'
...
READ THIS BEFORE YOU BUY
What you should know about R-Values
The chart shows the R-Value of thiS Insulation R means resistance to heat flow The higher the R-
Value, the greater the Insulating power Compare Insulation R-Values before you buy
There are other factors to consider The amount of Insulation you need depends mainly on the
climate you live In Also, your fuel savings from Insulation Will depend upon the climate, the type
and size of your house, the amount of Insulation already In your house, and your fuel use
patterns and family size If you buy too much Insulation, It Will cost you more than what you'll ~
save on fuel
To get the marked R-Value, It IS essential that thiS Insulation be Installed properly_
/
I
'.