HomeMy WebLinkAboutPermit Correspondence 2002-8-30
I:
l
.:.-;" ,~
"'.
)
BLOWING WOOL BATTS AND ROLLS
B""NEW CONSTRUCTION IF RETROFIT R-VALUE THICKNESS AREA INSULATED
D RETROFIT DEPTH OF PREVIOUS t-('( l'r _7 2-t{ SQ FT
22- INSUlATION CEILINGS IN
NUMBER OF BAGS USED INCHES
~I? 2-t.[ IN SQ FT
AREA INSUlATFD ESTIMATED R-VALUE OF 21 C g' ~5 -
sa FT' PREVIOUS INSUlATIO'l WALLS IN SQ FT
THICKNESS OF INSUlATION fer TYPE(S) OF PREVIOUS IN SQ FT
INCHES INSUlATION IN ATIIC FlOORS 30 (0 ~fYO
IN SQ FT
R-VALUE OF INSUlATION 0/1 IN ~Q FT
- I~:\~=
CLIMAl'~ PRO@ FIBER GLASS BLOWING WOOL
Your home has been professionally insulated to provide
a guaranteed thermal resistance.
HOAIEOWNE.R'S NA~
~.. - .
~ 0..9 (J"tf;A
Jh j I vi'" ,m
t,~<T.J:F 1/
ADDRESS I ~-fr t?
GIn
SrATE
ZlP
RECORD OF INSTALLATION
R-VALUE
CLIMATE PRO. BAG WEIGHT - 27 LB NOMINAL
MINIMUM BAGS PER MAXIMUM
THICKNESS 1000 SO FT NET COVERAGE
MINIMUM WEIGHT
PER SO" FT
To obtam an
msulatwn
reszstance
(R) oj
11
19
22
26
30
38
44
50
60
Installed 1 he number oJbag~ Contents oj
Insulatzon per 1000 5q ft oj thiS bag should
should not net area should not not cOlier
be less than be less than more than
525 m 64 156 sq ft
875m 113 88sq ft
9 75 III 128 78sq ft
11 50 m 156 64 sq ft
1275 In 176 57 sq ft ,
15 75 III 228 44 ~q ft
17 75 III 264 38 sq ft
19 50 In 298 34 sq ft
22 75 In 363 28 sq ft
J he wezght per
sq ft of Installed
msulatwn ~hould
not be less than
o 173 Ibs
o 306 Ibs
o 346 Ibs
o 420 Ibs
o 475 Ibs
06151bs
07131bs
o 804 Ibs
o 9811b.s
INSUlATION CONTRACTOR SIGNATUITh a ..:?~ ~ ~
COMPANY~ ~, fl L- /Qjl? A / ADDRES.~
- ;'111
PHONE
DATE ~ ~ j' 0 ~O z.... I
I
COMPANY
HOM\<. BUILDER SIGNATURF
PHONE
DATE
ADDRESS
~'tIIU
)GIhlJ1)$ MamvoUUe
~<!
'-' J' '-'
Johns ManVille PO Box 5108 Denver CO 80217 5108 wwwlm com For more Information call 1 800-6543103
THIS Is FIBER GLASS
BLOWING WOOL INSULATION
t-t'C FACT SHE:El '.,
..~'
CLIMATE PRO@ BLOWING WOOL INSULATION
Bag WeIght 27 lbs Nommal (MImmum Net WeIght of InsulatIOn In thIS Package IS 24 lbs )
R-VALUE MINIMUM BAGS PER MAXIMUM MINIMUM WEIGHT
THICKNESS 1000 SO FT NET COVERAGE PER SO FT
To obtain an Installed 1 he number of bags Contents of The wezght per
insulatIOn insulatIOn pIT 1000 sq ft of tillS bag should sq ft of installed
resistance should not net area should not not cover insulatIOn should
(R) of be less than be less than more than not be less than
11 525 In 64 156 sq ft o 173 Ibs
19 875 In 113 88 sq ft o 306 Ibs
22 975 In 128 78 sq ft o 346 Ibs
26 11 50 In 156 64 sq ft o 420 Ibs
30 12 75 In 176 57 sq ft o 4751bs
38 15 75 In 228 44 sq ft 06151bs
44 17 75 In 264 38sq ft 07131bs
50 19 50 In 298 34 sq ft o 804 Ibs
60 22 75 In 363 28sq ft o 981 Ibs
"\
Read This Before You Buy
What You Should Know About R-Values
The chart shows the R-value of thIS msulatIOn "R" means resIstance to heat flow The
hIgher the R-value, the greater the msulatmg power Compare InSUlatIOn R-values
before you buy
There are other factors to consIder The amount of InSUlatIOn you need depends
mamly on the clImate you lIve In Also, your fuel savmgs from InSUlatIOn wIll depend
upon the clImate, the type and SIze of your house, the amount ofmsulatIOn already In
your house, and your fuel use patterns and famIly SIze If you buy too much InSUlatIOn,
It WIll cost you more than what you'll save on fuel
To get the marked R-value, It IS essentIal that thIS msulatIOn be mstalled properly WIth
pneumatIC eqUIpment
.,--~
JiM
Johns Manville
Johns Manville
PO Box 5108
Denver, CO 80217-5.108
WWW Jm com , }:
, v
~.
,./
SIC 250 4/02