Insu Safe@4
Fiber Glass Blowing Insulation
InsulSafe@ 4 has been Installed In
-accordance with the manufacturer's
, r~ecommendatlons to provide a value of
". ~ L-~(5 ~bags of msulatlOn to
~- cove _ square feet 0.( area at a
m~m t~_of _ :5 mches
( ~ /1 I () r
In~tajler ContrilQ;Qr ( gn) I .- /'
~",e -t "':;;,;) Iff#' fl) ~ (...C ,
CO'J)flany Nam..; o? ......,
five vS" J C>",J Z-O<.1 ~
Dat-e/
"
\
,
Builder (sign)
Company Name
Date
Batts and Blankets
R-Value Insulation
Thickness (In)
38 10,12
30 8'/4, 10
25 8
22 6'/2
21 5'/2
19 6'/4
15 3'/2
13 3'/2
11 3'/2
Fiber glass balts or rolls have been
Installed In accordance with the
manufacturer's recommendations to
provide an R-value of 20 In the ....
celllng,;;\ In the extenor walls~'>
In the floor or c~wl space penmeter
t>~"' U!! 151t4v/"-
Ins!'jller Con~r (slg~) /"
~ N; :;. VI> J Id/6,., L.b
Company Na/mJ, " 0 d .,
fY)/t.., ) v V
Da-te /
Builder (sign)
Company Name
Date
Code No 30 24,233
THERMAL PERFORMANCE-A TIIC BLOWING APPLICATION
o In accordance with the chart below, you must Install the minimum number of bags
per 1,000 sq ft of net area for each R-Value listed
· The maximum net coverage must not exceed that specified for each R-Value
o The Installed insulation must be at or above the specified minimum thickness for
each R-Value
· Failure to Install the required minimum weight per sq ft of insulation at or ab,?ve
the minimum thickness will result In reduced R-Value
o This product should not be mixed with other blown insulations or the thermal
claims will become invalid
BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM
R VALUE 1 000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS
To obtain a Bags per Contents of bag weltt per sq ft of Should not be
Thermal ReSIStance 1000 sq ft should not cover Installe insulation should less than
(R) of of net area more than (sq ft) not be less than (Ibs) (In)
60 365 27 0986 22
49 . 296 34 0800 18'12 I
44 264 38 0712 16% , I
- ::"38_';; '"22 8- '-- 44---::' __06] 5_ ::- , 1.4% I
30 180 56 0485 12 I
26 15 5 65 0418 10'12 I
22 131 77 0353 9 I
19 111 90 0301 7% I
13 77 129 0209 5'12 I
11 _ 66 151 0179 4'14 I
R-values are determined In accordance with ASTM C 687 and 518
Compiles with ASTM C 764 as Type 1 insulation
"R"' means resistance to heat flow The higher the R-Value, the greater the
Insulating power To get the marked R-Valuel It IS essential that the
insulation IS Installed properly
DANGER RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING,
DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH
DEVICES DOES NOT APPLY TO TYPE IC LIGHT FIXTURES
OR TO FLUORESCENT FIXTURES WITH THERMALLY
PROTECTED BALLASTS
----
FRAMING ADJUSTMENT
To compensate for framing members the number of bags per 1000 sq ft
of net area should be reduced as follows
JOist Size
(m)
2x4
2x6
2x8
2 x 10
Bags to deduct!1000 sq It
JOists 16"OC
05
08
1 0
1 3
Bags to deduct!1000 sq It
/Olsts 24" 0 C
03
05
07
09
2000 Certameed Corporation 2!00
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation Insu -Safe@4
Fiber Glass Blowing Insulation
CertainTeed.
'r
CertalnTeed Corporation
PO Box 860
Valley Forge, PA 19482
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages specified when insulation IS Installed with
pneumatic equipment In a hOrizontal open blow application
BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM
R VALUE 1 000 sQ FT sQ FT PER BAG POUNDS PER sQ FT TH ICKN ESS
To obtain a Bags per Contents of bag weltt per sq It 01 Should not be
Thermal ReSIStance 1000 sq It should not cover Instal Ie insulation should less than
(R) 01 01 net area more than (sq It) not be less than (I bs ) (In )
60 365 27 0986 22
49 296 34 0800 18'/2
44 264 38 0712 16%
38 228 44 0615 14%
30 180 56 0485 12
26 155 65 0418 10'/2
22 131 77 0353 9
19 111 90 0301 73/4
13 77 129 0209 5'/2 (- -
11 66 151 0179 4%
R-values are determined In accordance with ASTM C 687 and 518 Compiles with ASTM C 764 as Type 1 insulation
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When Installed With pneumatic equipment In Sidewalls, the follOWing thermal performances are achieved at the
thicknesses, weights and coverages speCified
BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM
R VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS
To obtain a Bags per Contents 01 bag Wel~ht per sq It 01 Should not be
Thermal ReSIStance 1000 sq It should not cover Instal Ie insulation should less than
(R) 01 01 net area more tha n (sq It) not be less than (Ibs) (In )
29 358 28 0967 7'/4
22 272 37 0733 5'/2
16 198 51 0533 4
15 179 56 0483 3%
14 173 58 0467 3'/2
READ THIS BEFORE YOU BUY
What you should know about R-Values
The chart shows the R-Value of thiS Insulation R means resistance to heat flow The higher the R-
Value, the greater the Insulating power Compare Insulation R-Values before you buy
There are other factors to consider The amount of Insulation you need depends mainly on the
climate you live In Also, your fuel savings from Insulation Will depend upon the climate, the type
and size of your house, the amount of Insulation already In your house, and your fuel use
patterns and family size If you buy too much Insulation, It Will cost you more than what you'll
save on fuel
To get the marked R-Value, It IS essential that thiS Insulation be Installed properly
~\)' .t.~t ...
~