HomeMy WebLinkAboutPermit Correspondence 2003-1-5
CLIMAl'~ PRO@ FIBER GLASS BLOWING WOOL
Your home has been professionally insulated to provide
a guaranteed thermal resistance.
HOMEOWNDR'S NAMJ
C /Y -
ADDRES,\ 6' 0'-; c J-L55
CI I Y <: /J r ,')/) c.~-{J J I (?~ 1/)
-/' u' . -
I
/c'll
- ""
()K~
SfAfE
ZIP
RECORD OF INSTALLATION
BLOWING WOOL
BATTS AND ROLLS
THICKNESS
AREA INSULATED
IN SQ H
IN SQ FT
IN ~Q n
IN SQ FT
IN SQ H
IN SQ FT
~ N~w CONSTRUCTION
h RETROFIT
R VALUE
D REl ROFIT
DrPTl-I OF PREVIOU<;
INSULATION
CJoJI INt ~
NUMBER OF BACS USED
!..fa.
/Oq'{)
so FT
WALI<;
INCHES
AREA IN~ULATED
ESTIMAILD R-VAI UL OF
PREVIOUS INSULATION
zo
Tl-IICKNFS<; OF IN<;ULATION
1\n(s) m PREVIOUS
IN<;UIATION IN ATI IC
FLOORS
INCHES
Lie,
R-VAI UF OF INSULATION
CLIMATE PRO. BAG WEIGHT - 27 LB NOMINAL
MINIMUM BAGS PER MAXIMUM
THICKNESS 1000 sa FT NET COVERAGE
R-VALUE
MINIMUM WEIGHT
PER sa FT
/0 oblam an
lIHulatwn
m,/l/anrf
(R) oj
11
19
22
26
30
'38
44
50
60
InslallNI fhe nu mber oj bag~ Con ten Is oj
I1llulatzon per 1000 sq Jt oj tlm bal5 should
;/wuld nol nel ana 1/lOuld nol nol ro111'1
bf Ie;; than be l1'ss than 1/101 f than
1) 25 In 64 156 sq ft
8 75 In 113 88sq ft
9 75 In 128 78 sq ft
11 50 1I1 156 64 ~q ft
1275 In 176 57 sq ft
] 575 In 228 44 sq ft
17 75 In 264 '38 ~q ft
19 50 In 298 34 sq ft
22 75 1I1 363 28 sq ft
J he wl'1ghl p"
sq Jt oj mslaU1'd
m;ulallOn should
nol be less I ha n
o 1731b,
o 306 Ibs
o 346 Ibs
o 420 Ib<;
04751bs
06151b<;
07131bs
o 804 Ibs
o 981 Ibs
IN,",,""," CON "'A",,>R S'CNAm" 4 ~~/." -"l ~ '
COMPA~~ 17A..e/~A::c/CoJ/11nDRC
4~Lu DATI /- )"-0 ~
., ~. -
PHONl
HOMl BUILDLR SIGNATURE
DATL
COMPANY
ADDRI S<;
PHONL
5!J'm
j@Du01JslMliI101JViUUce
Johns ManVille PO Box 5108 Denver CO 80217 5108 wwwlm com For more Information call 1-800-654 3103
THIS Is FIBER GLASS
BLOWING WOOL INSULATION
t'l'C FACT SHEET
CLIMATE PRO@ BLOWING WOOL INSULATION
Bag WeIght 27 lbs Nommal (MmImum Net WeIght of InsulatIOn m thIS Package IS 24 lbs )
R-VALUE MINIMUM BAGS PER MAXIMUM MINIMUM WEIGHT
THICKNESS 1000 SO FT NET COVERAGE PER SO FT
10 obtam an Installed I he number of bags Contents of Thp wl'lght prr
msulatlOn msulatlOn per 1000 sq Jt of 11m bag should sq Jt of zmtalled
resHtance should not net area should not not cover zmulatlOn should
(R) of bp less than be less than more than not be less than
11 525 In 64 156 sq ft o 173 Ibs
19 875 In 113 88 sq ft o 306 Ibs
22 975In 128 78 sq ft o 346 Ibs
26 11 50 In 156 64 sq ft o 420 Ib~
30 1275 In 176 57 sq ft 04751bs
38 1575 In 228 44 sq ft 06151bs ~I
44 17 75 In 264 38 sq ft o 713 Ibs
50 19 50 In 298 34 sq ft o 8041bs
60 22 75 In 363 28 sq ft 0981 Ibs
Read This Before You Buy
What You Should Know About R-Values
The chart shows the R-value of thIS msulatIOn "R" means reSIstance to heat flow The
hIgher the R-value, the greater the msulatmg power Compare msulatIOn R-values
before you buy
There are other factors to consIder The amount of msulatIOn you need depends
mamly on the clImate you lIve m Also, your fuel saVIngs from msulatlon WIll depend
upon the clImate, the type and SIze of your house, the amount ofmsulatIOn already m
your house, and your fuel use patterns and famIly SIze If you buy too much msulatIOn,
It WIll cost you more than what you'll save on fuel
To get the marked R-value, It IS essentIal that thIS msulatIOn be mstalled properly WIth
pneumatIC eqUIpment
Jim
Johns Manville
Johns Manville
PO Box 5108
Denver, CO 80217-5108
WWW Jm com
BIC 250 4/02
@ 2002 Johns Manville