BATTS AND BLANKETS
FIBER GLASS BLOWING INSULATION
When Installed In accordance with the man
ufacturer's recommendations, Knauf batts
and blankets will provide the full R value
R 38HD
R 38
R 30HD 825"
R 30 1000"
R 26 900"
R 22 650"
R 21HD 550"
R 19 6 25"**
R 15HD 350"
R13 350"
R11 350"
R8 250"
;: ~Bag Weight-Nominal 28 Ibs MInimum 271bs
**R 18 In a 5 5 cavity (onforms to ASTM ( 665 and
Federal Specification HH I 521F
EQUIPMENT REQUIRED
THERMAL PERFORMANCE (ATTIC APPLICATION)
The stated thermal resistance (R value) IS provided by installing In accordance with the manufacturer's instructions,
the required number of bags per 1,000 sq ft of net area, at not less than the labeled minimum thickness Failure to
Install both the required number of bags and at least the minimum thickness Will result In lower insulation R value
. .,~ ~ '
.;~ -.";.:, "* ';.. .:.~~
",~ <",,!ALU~~. '.,
~- " To' obtain'an : /:-
insulation resistance";;;
~"!L'(~~v~iue)ro{:.: ~
R 60 378 26 5 SF 1 058 Ibs
R 50 310 32 2 SF 8691bs
R 44 269 37 2 SF 7531bs
R 38 229 43 6 SF 6421bs
R 30 179 55 9 SF 501 lbs
R 26 155 64 6 SF 433lbs
R22 127 78 4 SF 3571bs
R 19 109 92 0 SF 304lbs
R13 76r 131 6 SF 213 lbs 575"
R11 6~ 161 3 SF 174lbs 475"
ThiS product conforms to the performance requirements of ASTM ( 764, Type I and cancelled Federal Speclficallon HH 11030B Type I,
Class B R values are determined In accordance with (687 and (518
* R means resistance to heat Row The higher the R value, the greater the insulating power Ask your seller for the fact sheet on R values
FRAMING ADJUSTMENT
To achieve labeled R value, thiS product must be applied with a pneumatic blow
Ing machine and a corrugated hose with a minimum 25" Internal corrugatIOn, a
minimum length of 150 ft and a diameter of at least 3" COils In the hose should
not be less than 36" In diameter Acceptable material feed rate IS 5 35
Ibs /mlnute Recommended feed rate is 15 25 lbs /mlnute
2x4 373
R 60 2x6 I 371
2x8 I 368
2x4 '~'-'305 I 306
R 50 2x6 302 I 304
2x8 298 I 302,
2x4 263 I 265
R 44 2x6 260 i 263
2x8 257 \ I 260
2x4 224 I 225
R 38 2x6 221 I 223 _
2x8 218 I 221
2x4 174 I 175
R 30 2x6 171 I 173
2x8 168 171
2x4 150 151
R 26 2x6 147 149
2x8 144 147
2x4 123 -, 124
R-22 2x6 120 122
2x8 117 120
2x4 104 105
R 19 2x6 101 103
2x8 98 101
2x4 71 73
R13 2x6 68 71
2x8 66 69
2x4 57 59
R 11 2x6 55 57
2x8 52 55
BUILDER'S INSULATION STATEMENT
Batts and/qr blankets have been Installed In conformance With the above recom
mendatloP~ to proVide a thermal resistance of
. . '. .
(~~'~t:J~'>:.i~:~::{~~~j}~~'~;'~:_~~{:~~~,,~ ~{~. ~-~~l~~~', ~~:~^:', '~\;;.~?~h~~D$~~.:~-)~'J<
AttiC Area tOO R- 3ct at \ S ~ Inches
Sloped Ceilings I~O R oD at \0 Inches
Walls 11(01, 'Z.-t .- .-
R at ~ -'5 Inches
Floors (over an unheated crawl space) (5-5 t R % at ct Inches
Crawl Space Perimeter
, \
",) ~
Date Installed Z10 / D
I I
Blown insulation has been Installed In conformance wl~the above
recomrendatlons to prOVide an R value of R 37) ....... uSing
f.R bags of thiS insulation to cover I D U square feet
"";;;;;;~A~'
ontrac r s.gnature) M
.. .,'''' ~-\l
':..-~"'i ~"\~
.;{ ~--~
.... ~ --- 1""
~-
~
I
Home BUilder (signature)
(ompany
~
BW AC 08 5/02
Knauf Fiber Glass, One Knauf Drive, ShelbYVllle, IN 46176 (800) 8254434
R
at
Inches
'}../~~ iDS
I Date
Date
CLOSED-CAVITY APPLICATION