Loading...
HomeMy WebLinkAboutPermit Correspondence 2003-3-4 CertainTeed II Builders Statement . n \ I~--V\ cl- i ~UAlLO '^ ils Hom"'i,,, ~l' ~b;'" "'7\ - CO~:5 ~l-ff , , Installer/Contractor (sign) BUilder (sign) Inspected By (sign If required) R-VALUE j To obtain a Thermal ReSistance (R) of 60 49 44 38 30 26 22 19 13 11 CEILINGS t.ei2.1"'~ WALLS '- FLOORS InsulSafe@4 Fiber Glass Blowing Insulation k .~~~~~'~ 0h-~3 bate { Company Name Company Name Date Date BAGS PER MAXIMUM MINIMUM WEIGHT- 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT Bags per Contents of bag Weight per sq ft of 1000 sq It should not cover Installed insulation should of net area more than (sq ft) not be less than Qbs) 365 27 0986 296 34 0800 264 38 0712 228 44 0615 180 56 0485 155 65 0418 131 77 0353 111 90 0301 77 129 0209 66 151 0179 R-VALUE THICKNESS AREA (SQ FT) INSULSAFE 4 (II) &3 \4-~'f )175 V \ IZ/I .=:8 4r:o &) 10/1 /000 dl 5-t'. 15c?5 ::J:=) ~~" '<:150 MINIMUM THICKNESS Should not be less than I On) 22 18V, 16:y.. 14:y.. 12 lOV, 9 7:% 5'12 4:y.. BAGS USED BATTS/ROLLS (II) c90 v ./' ,/ ,/ THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must Install the minimum number of bags per 1,000 sq ft of net area for each R-Value listed . The maximum net coverage must not exceed that specified for each R-Value . The Installed Insulation must be at or above the specified minimum thickness for each R-Value . Failure to Install the required minimum weight per sq ft of insulation at or above the minimum thickness Will result In reduced R-Value . This product should not be mixed with other blown insulations or the thermal claims Will become Invalid DANGER RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS 30-24-233 BUilders Statement A Saint Gobaln Company @2002 CertalnTeed Corporation 1/02 Manufacturer Insulation Fact Sheet This is CertainTeed Corporation Insu Safe@4 Fiber Glass Blowing Insulation CertainTeed. Certain Teed Corporation PO Box 860 Valley Forge, PA 19482 THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW The following thermal performances are achieved at weights and coverages speCified when insulation IS Installed with pneumatic equipment In a hOrizontal open blow application BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM R VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS To obtain a Bags per Contents of bag Weight per sq ft of Should not be Thermal ReSIStance 1000 sq ft shou Id not cover Installed insulation should less than (R) of of net area more than (sq ft) not be less than (Ibs) (In ) 60 365 27 0986 22 49 296 34 0800 18'h 44 264 38 0712 16% 38 228 44 0615 14% 30 180 56 0485 12 26 155 65 0418 10'h 22 131 77 0353 9 19 111 90 0301 7% 13 77 129 0209 5'h 11 66 151 0179 4% R-values are determined In accordance with ASTM C 687 and 518 Complies with ASTM C 764 as Type 1 insulation THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION When Installed with pneumatic equipment In sidewalls, the following thermal performances are achieved at the thlcknessesl weights and coverages specified BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM R VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS To obtain a Bags per Contents of bag Weight per sq ft of Should not be Thermal ReSistance 1000 sq ft should not cover Installed insulation should less than (R) of of net area more than (sq ft) not be less than (Ibs) (In ) 29 358 28 0967 7'/4 22 272 37 0733 5'h 16 198 51 0533 4 15 179 56 0483 3% 14 173 58 0467 3'h READ THIS BEFORE YOU BUY What you should know about R-Values The chart shows the R-Value of thiS Insulation R means resistance to heat flow The higher the R- Value, the greater the Insulating power Compare Insulation R-Values before you buy There are other factors to consider The amount of Insulation you need depends mainly on the climate you live In Also, your fuel savings from Insulation will depend upon the climate, the type and size of your house, the amount of Insulation already In your house, and your fuel use patterns and family size If you buy too much Insulation, It will cost you more than what you'll save on fuel To get the marked R-Value, It IS essential that thiS Insulation be Installed properly