Loading...
HomeMy WebLinkAboutPermit Correspondence 2003-4-14 7 rr:; ~ / CertainTeed II Builders Statement InsulSafe@4 Fiber Glass Blowing Insulation tJ2, I-MY... ^~ h If> Homeowner Name / Jobslte Name fJ,qfl;"J)'I 'Sl, ~Address J (J1;1 ~/(JI' Installer/Contractor (s~n) fI. () f'I1P -'.. n< " k-r- A'" {L . - Company Name BUilder (sign) Company Name Inspected By (sign If required) BAGS PER MAXIMUM MINIMUM WEIGHT- R-VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT To obtam a Bags per Contents of bag Weight per sq It ,of Thermal ReSistance 1000 sq It should not cover ~mstalled msulatlon should (R) of of net area more than (sq It) not be less than (Ibs) 60 1 365 27 0986 49 1 296 34 0800 44 1 264 38 0712 38 1 228 44 0615 30 I 180 56 0485 26 1 155 . 65 0418 22 1 131 77 0353 19 I' 111 90 0301 13 I 77 129 0209 11 I 66 151 0179 " , R-VALUE THICKNESS AREA (SQ FT) INSULSAFE 4 (iI) . ""~ ";. 3ft {gOO ./ " CEILINGS . .. ~ 3$? )1% ()dO V , I WALLS ~I 2. ZOO I '''''I' I FLOORS Q-..5 /)SO I THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION /{p.,.." ) ~f Zo oJ Date '. -;' :-~,..~ .. r .. I- ~l, t.... 1 1 I 1 1 , 1 -, 1-", , ' '1,-, .' . I ' .1 -i: BAGS USED /9 >,,, Date Date ~,' .. MINIMUM THICKNESS Should not be less than I (m) 22 18Y2 ..~ 16% 14';' 12 10'/, 9 " 7% 5'/, 4% BATTS~ROL'0 V' /' ./ V /' V . In accordance WIth the chart above, you must Install the minImum number. of bags per 1,000 sq ft of net area for each R-Value listed . The.ma~lmum net coverage must not exceed that specified for each R-Value . The Installed Insulation must be at or above the specified minimum thickness for each R-Value . Failure to Install the reqUIred minimum weight per sq ft of Insulation at or above the minimum thickness Will result In reduced R-Value . This product should not be mixed With other blown InsulatIons or the thermal claims Will become Invalid \ DANGER: RECESSED LIGHT FIXTURES-TO PREVENT O}/ERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. DOES NOT APPLY TO TYPE Ie L.l,GHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. 30-24-233 BUilders Statement \, A Samt-G~bam Company @2002 Certain Teed Corporation 1/02 - '^ --- " Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@4 -Fiber Glass Blowing Insulation CertalnTeed Corporation PO Box 860 Valley Forge, PA 19482 "'- ;.~ s.:-~ 01........ .." . -~., ~ CertainTeed. THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW The following thermal performances are achieved at weights and coverages specified when insulation IS Installed with pneumatic equipment In a hOrizontal open blow application BAGS PER MAXIMUM R-VALUE 1000 SQ FT SQ FT PER BAG To obtain a Bags per Contents of bag Thermal Resistance 1000 sq ft shou Id not cover (R) of of net area more than (sq ft) 60 365 27 49 296 34 44 264 -;. 38 - 38 228 44 30 180 56 26 155 65 22 131 77 '19 111 90 13 77 129 11 66 151 MINIMUM WEIGHT- MINIMUM POUNDS PER SQ FT THICKNESS Weight per sq ft of Shou Id not be Installed insulation should less than not be less than (Ibs) (In ) 0986 22 0800 18';' 0712 16% 0615 14% 0485 12 0418 10';' 0353 9 0301 7'1. 0209 5';' 0179 4% R-values qre dete-rmlned In accordance with ASTM C 687 and 518 Complies with ASTM C 764 as Type 1-lnsulatlon ~f\ THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION When'l'nstalled with pneumatic equipment In Sidewalls, the follOWing thermal performances are achieved at the thicknesses, weights and coverages speCified j~ ~~ BAGS PER MAXIMUM MINIMUM WEIGHl- MINIMUM R-VALUE 1000 SQ FT SQ FT PER BAG POU N OS PER SQ FT TH ICKN ESS To obtain a Bags per Contents of bag Weight per sq ft of Should not be Thermal ReSIStance 1000 sq ft . should not cover Installed insulation should less than - (R) of of net area more than (sq ft) not be less than (Ibs) (In ) 29 358 28 0967 7'/4 22 272 37 0733 5';' 16 198 - 51 0533 4 15 179 56 0483 3% 14 173 58 0467 3';' READ THIS BEFORE YOU BUY What you should know about R-Values The chart shows the R-Value of thiS Insulation R means resistance to heat flow The higher the R- Value, the _greater the Insulating power Compare Insulation R-Values before you buy There are other factors to consider The amount of Insulation you need depends mainly on the climate YQu live In Also, your fuel savings from Insulation Will depend upon the climate, the type and size of your house, the amount of Insulation already In your house, and your fuel use patterns_and family size If you buy too much Insulation, It will cost you more than what you'll save on fuel To get the marked R-Value, It IS essential that thIS Insulation be Installed properly "' ';" ...'"