HomeMy WebLinkAboutPermit Correspondence 2003-4-25
CertainTeed II
Builders Statement
...) .,-...,
~?
InsulSafe@4
Fiber Glass Blowing Insulation
~fv.. LL(::_A~~
1le..~l ~ ~~ \ l'\ ,'"u ~
Hom~WQ' 1m~JOb:J;M ~ _
r5:lSSQ 1-7)(d JuJLcd1 M
Installer/Contractor (sign)
BUilder (sign)
::",,:..4
>_ (n'spected By (sign If required)
R-VALUE
To obtain a
Thermal ReSistance
(R) of
60
49
44
38
30 .
26
22
19
13
11
CEILINGS
WALLS
fl
"
FLOORS
Company Name
4-/2.5/ Z1103
f Date (
Company Name
Date
Date
BAGS PER MAXIMUM MINIMUM WEIGHT-
1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT
Bags per Contents of bag Weight per sq It of
1000 sq It should not cover Installed insulation should
of net a rea more than (sq It) not be less than Obs)
365 27 0986
296 34 0800
264 38 0712
228 44 0615
180 56 0485
155 65 0418
131 77 0353
111 90 0301
77 129 0209
66 151 0179
R-VALUE THICKNESS AREA (SQ FT) INSULSAFE 4 (01)
a~ i 2" ~35
.:2JO 10" R15
~I Sf" /950
d;;) ~ '1 /bdo
MINIMUM
THICKNESS
Should not be
less than I
(In)
22
18Y,
16%
14'/4
12
10V,
9
7%
5Y,
4%
BAGS USED
BATTS/ROLLS (01)
.v'
i/
t/'
I-
I
I
I
v
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
- In accordance With the chart above, you must Install the minimum number of bags per 1,000 sq ft of net area for each
R-Value listed
. The maximum net coverage must not exceed that specified for each R-Value
. The Install~d Insulation must be at or above the specified minimum thickness for each R-Value
. Failure to: Install the requIred minimum weight per sq ft of Insulation at or above the minimum thickness Will result In
reduce~ R-;Value
. ThiS product should not be mixed With other blown insulations or the thermal claims Will become Invalid
/ DANGER: ,RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
'SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH
.::T~ERMALLY PROTECTED BALLASTS.
30-24-233 BUilders Statement
..;.
<;.
A Samt-Gobam Company
@2002 CertamTeed Corporation 1/02
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation Insu Safe@4
Fiber Glass Blowing Insulation
Certain Teed Corporation
PO Box 860
Valley Forge, PA 19482
CertainTeed.
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages specified when insulation IS Installed with
pneumatic equipment In a hOrizontal open blow application
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R-VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT TH ICKN ESS
To obtain a Bags per Contents of bag Weight per sq ft of Should not be
Thermal ReSIStance 1000 sq ft should not cover Installed insulation should less than
(R) of of net area more than (sq ft) not be less than (Ibs) (In) ..
60 365 27 0986 22
49 296 34 0800 18'/2
44 264 38 0712 16%
38 228 44 0615 14%
30 180 56 0485 12
26 155 65 0418 10'/2
22 131 77 0353 9
19 111 90 0301 7%
13 77 129 0209 5'/2
11 66 151 0179 4%
R-values are determined In accordance with ASTM C 687 and 518 Compiles with ASTM C 764 as Type 1 insulation
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When Installed with pneumatic equipment In sldewallsl the following thermal performances are achieved at the
thicknesses, weights and coverages speCified
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R-VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT TH ICKN ESS
To obtain a Bags per Contents of bag Weight per sq ft of Should not be
Thermal ReSIStance 1000 sq ft should not cover Installed Insulalion should less than
(R) of of net area more than (sq ft) not be less than (Ibs) (In)
29 358 28 0967 7'/4
22 272 37 0733 5'/2
16 198 51 0533 4
15 179 56 0483 3%
14 173 58 0467 3'/2
READ THIS BEFORE YOU BUY
What you should know about R-Values
The chart shows the R-Value of this Insulation R means resistance to heat flow The higher the R-
Value, the greater the Insulating power Compare Insulation R-Values before you buy
There are other factors to consider The amount of Insulation you need depends mainly on the
climate you live In Also, your fuel savings from Insulation Will depend upon the climate, the type
and size of your house, the amount of Insulation already In your house, and your fuel use
patterns and family size If you buy too much Insulation, It Will cost you more than what you'll
save on fuel
To get the marked R-Value, It IS essential that this Insulation be Installed properly