Loading...
HomeMy WebLinkAboutPermit Correspondence 2003-2-1 IO~ I . 4 ~df)cJ I Lot q FIBER GLASS BLOWING INSULATION When Installed In accordance with the man- ufacturer's recommendations, Knauf batts and blankets will provide the full R.value. THERMAL PERFORMANCE (ATTIC APPLIC~TION) ~I' t~ The stated thermal resistance (R-value) IS provided by installing In accordance\wlth the manufacturer's Instructlons,r~!:;' the required number of bags per 1,000 sq ft of net area, at not less than the\l~beled minimum thickness Failure to:1: Install both the required number of bags and at least the minimum thickness ~~il:result In lower insulation R-value~ ~~ ~:f!::'t I' " I. ~ BATTS AND BLANKETS ~4~ ':-- ~..~':,,,~~~~;r_-.~'" ~.~; i.. :' R-VACUE* '.,' I' "; :To,obtain 'an " '.'. 'ffnsulaH<<{~'resistancl! ~ ~~.; ~(~;~aJ~~)I.of::;;t~ .' ~ . I ~ : . THI~~NESS. . . Installed insulation : . shouid not bl! ': : = 'l'-~. ~l@s~ than: '^ ',,': ~_~ R-38HD R.38 R.30HD R.30 R.26 R.22 R-21HD R-19 R.15HD R-13 R.ll R.8 . . . 825" 1000" 9 00" 6 50" 5 50" 6 25"** 3 50" 3 50" 3 50" 2 50" R-60 378 26 5 SF 1 058 lbs 2350" R-50 310 32 2 SF 869lbs 2000" R.44 269 37 2 SF 753 lbs 1775" R.38 229 43 6 SF 642lbs 1550" R-30 179 55.9 SF 501 lbs 1250" R.26 155 64 6 SF 433 lbs 1100" R-n 127 78 4 SF 357 Ibs 925" R-19 109 92 0 SF 304lbs 800" R-13 76 131 6 SF 213 Ibs 575" R-ll 62 161 3 SF 174lbs 475" Bag Weight-Nominal 28 Ibs , MInimum 27 Ibs "R-18 In a 5 5" cavity (onforms to ASTM (665 and Federal Specification HH.I.521F ThiS product conforms to the performance reqUIrements of ASTM ( 764. Type J, and cancelled Federal SpeCificatIOn HH.I-1030B, Type I, Class B R-values are determined In accordance with (687 and (518 '''R'' means resistance to heat flow The higher the R-value. the greater the insulating power Ask your seller for the fact sheet on R-values EQUIPMENT REQUIRED To achieve labeled R-value, thiS product must be applied with a pneumatic blow. Ing machine and a corrugated hose with a minimum 25" Internal corrugation, a minimum length of 150 ft and a diameter of at least 3" COils In the hose should not be less than 36" In diameter Acceptable material feed rate IS 5-35 Ibs /mlnute Recommended feed rate IS 15.25 lbs /mlnute BUILDER'S INSULATION STATEMENT . Batts and/or blankets have been Installed In conformance With the above recom. mendatlons to prOVide a thermal resistance of t.l:~'~~:!~~1~F~ !~~:~,:?~~j;:~~t:f~ t.:!.~~, :\,~ i~~~~~"'~ .~: 1~1v?!~.~':~:.~~ i:".l _: "T~hi.~~.n~~~~~\:~~~'~,^ AttiC Area R.38 atjS; S Inches Sloped Ceilings R- 3~ at It,}". S- Inches Walls R- 21 at ~ Inches Floors (over an unheated crawl space) R- 2-'J at ~ Inches Crawl Space Perimeter R- at Inches <2./0:> ( Blown insulation has been Installed In conformance With the above Date Installed recommendations to prOVide an R-value of R. ? b bags of thiS insulatIOn to cover of7 ;~um =:: of ""s~on"(ontractor (signature) 3~ (roOf) uSing square feet Inches ~ Company Oate Home Builder (signature) Company Date F RAM lNG' A D JUS T MEN T To compensate for framing members, the number of bags per 1,000 sq ft. of area to be Insulated should be as shown below :," I' I 2x4 372 373 R-60 2x6 368 371 2x8 365 368 2x4 305 306 R-50 2x6 302 304 2x8 298 302 2x4 263 265 R-44 2x6 260 263 2x8 257 260 2x4 22.4 225 R.38 2x6 221 223 2x8 218 221 2x4 174 175 R-30 2x6 171 173 2x8 168 171 2x4 150 15.1 R.26 2x6 147 14.9 2x8 144 147 2x4 123 124 R-22 2x6 120 122 2x8 117 12.0 2x4 104 105 R-19 2x6 10.1 103 2x8 98 101 2x4 71 7.3 R.13 2x6 6.8 7.1 2x8 66 69 2x4 57 59 R-ll 2x6 5.5 57 2x8 52 55 CLOSED-CAVITY APPLICATION (EXTERIOR SIDEWALL OR FLOORED ATTICS) Contact Knauf Fiber Glass for more informatIOn BW-AC-08 5/02 Knauf FIber Glass, One Knauf Drive, ShelbYVllle, IN 46176 (800) 825-4434 Printed In USA