HomeMy WebLinkAboutPermit Correspondence 2004-4-23 ?' f FIBER GL~ BLOWING " \ BATTS AND BLANKETS When Installed In accordance with the man- ufacturer's recommendations, Knauf batts and blankets will provide the full R-value MINIMUM ~-VALUE* THICKNESS To obtain an Installed insulation insulation resistance should not be (R) of: less than: j" I R-38 1200" R-30HD 825" R-30 1000" R-26 900" R-n 650" R-21HD 550" R-19 625"** R-15HD 350" R-13 350" R-11 350" R-8 250" Bag Weight-Nominal 28 Ibs , Minimum 27 Ibs **R 18 In aSS" cavity Conforms to ASTM C 665 and Federal SpeCification HH 1-521F EQUIPMENT REQUIRED INSULATION THERMAL PERFORMANCE (ATTIC APPLICATION) The stated thermal resistance (R-value) IS provided by installing In accordance with the manufacturer's instructions, the required number of bags per 1,000 sq ft of net area, at not less than the labeled minimum thickness Failure to Install both the required number of bags and at least the minimum thickness will result In lower insulation R-value R-VALUE* To obtain an insulation resistance (R-value) of: !lAGS PE~ 1,000 SQ. FT. The number of ba~s per 1,000 sq. ft. of netarea should not be less than: MINIMUM WEIGHT PER SQ. FT. The wei~ht per sq. ft. of installed insulation sohould not be less than: MAXIMUM NET COVERAGE Contents of this ba~ should not cover more than: MINIMUM THICKNESS Installed insulation should' not be less than: R-50 R-44 R-38 R-30 R-26 R-n R-19 R-13 R-ll 378 26 5 SF 1 058 Ibs 310 32 2 SF 869 Ibs 269 37 2 SF 7531bs 229 43 6 SF 642 Ibs 179 55 9 SF 501 Ibs 15 5 64 6 SF 4331bs 127 78 4 SF 3571bs 925" 109 92 0 SF 3041bs 800" 76 131 6 SF 213 lbs 575" 6 2 161 3 SF 174 Ibs 475" '" , II ThiS product conforms to the performance requrrements of ASTM C 764, Type I, and cancelled Federal SpeCifICation HH-ll030B, Type I, Class B R values are determined In accordance with C 687 and C 518 *"R" means resistance to heat flow The higher the R value, the greater the insulating power Ask your seller for the fact sheet on R-values To achieve labeled R-value, thiS product must be applied with a pneumatic blow- 'ng machine and a corrugated hose with a minimum 25" Internal corrugation, a nlnlmum length of 150 ft and a diameter of at least 3" COils In the hose should not be less than 36'! In diameter Acceptable mateTlal feed rate IS 5-35 Ibs /mlnute Recommended feed rate IS 15-251bs /mlnute BUILDER'S INSULATION STATEMENT Batts and/or blankets have been Installed In conformance with the above recom- mendations to provide a thermal resistance of R-Value Thickness AttiC Area. R- Sloped Ceilings R- Walls R- Floors (over an unheated crawl space) R- Crawl Space PeTlmeter R- Date Installed L;'z ~-oLj Ljq at //Unches I at Inches at Inches at Inches at Inches Blown insulation has been Installed In conformance with the above recommendations to provide an R-value of R- Y ~ uSing "=S C/ bags of thiS insulation to cover .I O<gr/ square feet ..... / of area at a minimum thickness of ~e::f:::> Inches 4~~~~--"7vf A;<~~ Insulation Cont~~y~~) / ~ rJ/..,J / ~ J?.r ~ 9 {:()/!,- Company '--- I V' / ' , Date " Home BUilder (signature) Company BW-AC-08 5/02 Date FRAMING ADJUSTMENT To compensate for framing members, the number of bags per 1,000 sq ft of area to be Insulated should be as shown below I JOIST BAGS/MSF R-VAL'l DIMENSIONS 16" O.c. FRAMING R-60 2x6 368 2x8 365 2x4 305 R-50 2x6 302 2x8 298 2x4 263 R-44 2x6 260 2x8 257 2x4 224 R-38 2x6 221 2x8 218 2x4 174 R-30 2x6 171 2x8 168 2x4 150 R-26 2x6 147 2x8 144 2x4 123 R-22 2x6 120 2x8 117 2x4 104 R-19 2x6 101 2x8 98 2x4 71 R-13 2x6 68 2x8 66 2x4 57 R-ll 2x6 55 2x8 52 BAGS/MSF 24" O.c. FRAMING 373 371 368 306 304 302 265 263 260 22 5 223 221 175 173 171 151 149 147 124 122 120 105 103 10.1 73 71 69 59 57 5 5 CLOSED-CAVITY APPLICATION (EXTERIOR SIDEWALL OR FLOORED ATTICS) Contact Knauf Fiber Glass for more information Knauf Fiber Glass, One Knauf DTlve, ShelbYVllle, IN 46176 (800) 825-4434 PTlnted In USA