Loading...
HomeMy WebLinkAboutPermit Correspondence 2000-9-21 2~55 ?Ij ~5 -Ii? 5;: ~@[f l@omt@@cQ s Builders Statement "---- \ InsulSafe@4 Fiber Glass Blowing Insulation \ InsulSafe@ 4 has been installed in accordance with the manufacturer's ~fmendatio~ to provide a value of R usiJ!g If c, bags of insulation to ver J(lc.., Qsquare ~e/~ea at a minimum-thickness o~c~ /MA~ha1J'~ In~taller Contractor (~~iv (' J qOl]lea)1Y J'!ame "----""- 4:f{)JV/ fi-- /J..i<;I//.A IlOA r ,. ~ ~ ., Dat 2 7/, IlO Bud? r (slgnl ' / Company Name Date Batts and Blankets R-Value Insulation Thickness (In) 38 10,12 30 8'/4, 10 25 8 22 6'(, 21 5'(, 19 6'/4 15 3'(, 13 3 ,(, 11 3 '/2 Fiber glass batts or ro Is have been installed in accordance with the manufacturer's recommendations to provide an R-value of _ in the ceiling, _ in the exterior walls, _ in the floor or crawl space perimeter. Installer Contractor (sign) Company Name Date '\ Budder (sign) Company Name Date Code No 30,24-233 THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION · In accordance With the chart below, you must Install the minimum number of bags per 1,000 sq ft of net area for each R-Value listed · The maximum net coverage must not exceed that specified for each R-Value · The Installed insulation must be at or above the specified minimum thickness for each R.Value · Failure to Install the required minimum weight per sq ft of insulation at or above the minimum thickness will result In reduced R-Value · ThiS product should not be mixed With other blown insulations or the thermal claims will become invalid I BAGS PER : MAXIMUM MINIMUM WEIGHT, MINIMUM R.VALUE 1 000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS To obtain a Bags per Contents 01 bag weltt per sq It 01 Should not be Thermal ReSIStance 1000 sq It should not cover Installe insulation should less than (R) 01 01 net area more than (sq It) not be less than (Ibs) (In ) 60 365 27 0986 22 49 296 34 0800 18'/1 44 264 38 0712 16% 38 228 44 0615 14% 30 180 56 0485 12 26 15 5 65 0418 10'/1 22 131 77 0353 9 19 111 90 0301 73/4 13 77 129 0209 5'/1 11 66 151 0179 4'14 R-values are determined In accordance With ASTM C 687 and 518 Compiles With ASTM C 764 as Type 1 insulation "R" means resistance to heat flow The higher the R-Value, tne greater the insulating power To get the marked R-Value, It IS essential that the insulation IS Installed properly DANGER RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS FRAMING ADJUSTMENT To compensate for framing members the number of bags per 1000 sq ft of net area should be reduced as follows JOIst S,ze (In) 2x4 2 x 6 2x8 2 x 10 Bags to deduct/l000 sq ft JOists 16" 0 C 05 08 10 1 3 Bags to deduct/l000 sq It JOIsts 24" 0 C 03 05 07 09 2000 Certalneed Corporation 2/00 Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@4 Fiber Glass Blowing Insulation Certain Teed Corporation PO Box 860 Valley Forge, PA 19482 ~~[f~@D[(l)U~~cgJ ~ THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW The following thermal performallc:es are achieved at weights and coverages speCified when insulation IS Installed with pneumatic equipment In a hOrizontal open blow application .'~~, BAGS PER MAXIMUM MINIMUM WEIGHT, MINIMUM R-VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS To obtam a Bags per Contents of bag weltt per sq ft of Should not be Thermal ReSIStance 1000 sq ft should not cover mstalle msulatlon should less than (R) of of net area more than (sq ft) not be less.than (Ibs) (m) 60 365 27 0986 22 49 296 34 0800 18'12 44 264 38 0712 163/, 38 228 44 0615 143/, 30 180 56 0485 12 26 155 65 0418 10'12 22 131 77 0353 9 19 111 90 0301 7% 13 77 129 0209 5'12 11 66 151 0179 43/, R-values are determined In accordance with ASTM C 687 and 518 Complies with ASTM C 764 as Type 1 insulation THERMAL PERFORMANCE-SIDEWAll RETROFIT APPLICATION When Installed with pneumatic equipment In sidewalls, the follOWing thermal performances are achieved at the thicknesses, weights and coverages speCified BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM R,VALUE 1000 SQ FT SQ FT PER BAG POUNDS PER SQ FT THICKNESS To obtam a Bags per Contents of bag welJht per sq ft of Should not be Thermal ReSIStance 1000 sq ft should not cover mstalle msulatlon should less than (R) of of net area more than (sq ft) not be less than (Ibs) (m) 29 358 28 0967 7'/, 22 272 37 0733 5'12 16 198 51 0533 4 15 179 56 0483 3% 14 173 58 0467 3'12 READ THIS BEFORE YOU BUY What you should know about R-Values The chart shows the R-Value of thiS Insulation R means resistance to heat flow The higher the R- Value, the greater the Insulating power Compare Insulation R-Values before you buy There are other factors to consider The amount of Insulation you need depends mainly on the climate you live In Also, your fuel savings from Insulation Will depend upon the climate, the type and size of your house, the amount of Insulation already In your house, and your fuel use patterns and family size If you buy too much Insulation, It Will cost you more than what you'll save on fuel To get the marked R-Value, It IS essential that thiS Insu!atlon be Installed properly j "f