HomeMy WebLinkAboutPermit Correspondence 2001-7-11
o
CLlMAl'~ PRO@ FIBER GLASS BLOWING WOOL
Your home has been professionally insulated to provide
a guaranteed thermal resistance.
HOMEOWNER'S NAME
ADDR/i'<;<; 4ld1J Hi JJOIi1 (01 d!-
CITY ~t)W1fA Y7 ( i
r--
Pi-
r7f7ff
~ ,
'-~.
SQ IT
SQ IT
SQ IT
SQ IT
SQ IT
SQ IT
Zip
STATE
........ ~
RECORD OF INSTALLATION
BLOWING WOOL
~EW CONSTRucrION IF RETROFIT
BAns AND ROLLS
II-VALUE THICKNESS AREA INSULATED
o RETROFIT
DEPTH OF PREVIOUS
INSUlATION
CEILlNGS~!'J~ Z;;~ ~_
Mil- H~ 71< ~JfI (~~
WALLS ~~ 2( . ~ IN 1ztz::D
().5
INCHES
NUMBER OF BAGS USED
AREA INSULATED
"'Jb'il' ESTIMATED R-VAI UE OF
SO FT PREVIOUS INSULATION
J THICKNESS OF INSULATION [)o
INCHES
FLOORS Y-/lf}
_( 0 tf
IN
IN lOA!:?
TYI'E(S) OF PREVIOUS
INSULATION IN ATTIC
R-VALUE OF INSUlATION 11-6(
IN
R-VALUE
CLIMATE PRO. BAG WEIGHT - 25 LB. NOMINAL
MINIMUM BAGS PER MAXDMUM
THICKNESS 1000 SO. n. NET COVERAGE
MINIMUM WEIGHT
PER SO. n.
To obtam an
msulatlOn
resIstance
(R) of
11
19
22
26
30
38
44
50
60
Installed
msulatlOn
should not
be less than
The number of bags
per 1000 sq ft of
net area should not
be less than
Contents of
thH bag should
not cover
more than
The wmght per
sq ft of mstalled
msulatlOn should
not be less than
70
125
146
172
20.0
263
305
355
430
142 sq ft
79 9 sq ft
68.4 sq ft
580sq ft
50,0 sq ft
38.0 sq ft
32.8 sq ft
28 2 sq ft
23.2 sq ft
o 176 Ibs
03131bs
o 365 Ibs
o 431 Ibs
o 500 Ibs
o 659 Ibs
o 763 Ibs
o 886 Ibs
1 076 Ibs
5Xm
8%m
10m
llMm
13m
16){ m
18){'m
20Mm
23Xm
~/ /':' --
INSULATION CONTRACTOR SIGNAT~~ ~ ~ {
COMPANVkwf JtJY/e~~AnDRESs/fZ;D tr//~ ~ ~
HOME BUILDER SIGNATURE Flf~/ eiZ 11'10 I
DAn 7/11;;
PHONLM ;?l6-
097'<
DATE
COMPANY
AnDRESS
PHONE
mr
Johns Manville
Johns ManVille Corporation, PO Box 5108, Denver CO 80217-5108, Internet httpllwwwJm com For more information call 1-800-654,3103
l
THIS Is FIBER GLASS
BLOWING WOOL INSUlATION
}"!'C FACT SHEET
o
CLIMATE PRO™ BLOWING WOOL INSUlATION
Bag Weight 25lbs, Nominal (Minimum Net ~eight of Insulation In this Package is 23Ibs.)
R-VALUE MINIMUM BAGS PER MAXIMUM MINIMUM WEIGHT
THICKNESS 1000 50. n. NET COVERAGE PER 50. n.
To obtain an Installed The number of bags Contents of The wezght per
InsulatlOn InsulatlOn per 1000 sq ft of thIs bag should sq ft of Installed
resIstance should not net area should not not cover InsulatlOn should
(R) of be less than be less than more than not be less than
11 5J4m 70 142 sq ft o 1761bs
19 8% m 125 79 9 sq ft 03131bs
22 10m 146 68 4 sq ft o 365 Ibs
26 l1~m 172 58 0 sq ft o 4311bs
30 13 m 200 50 0 sq ft o 500 Ibs
38 16Xm 263 38 0 sq ft o 659 Ibs
44 18J4 m 305 32 8 sq ft o 763 Ibs
50 20~m 355 28 2 sq ft o 886 Ibs
60 23;4 m 430 23 2 sq ft 1 076 Ibs
Read This Before You Buy
What You Should Know About R-Values.
The chart shows the R-value of this insulation. "R" means resistance to heat flow. The
higher the R-value, the greater the insulation power. Compare insulation R-values
before you buy.
There are other factors to consider. The amount of insulation you need depends
mainly on the climate you live in. Also, your fuel savings from Insulation WIll depend
upon the climate, the type and SIze of your house, the amount of insulation already in
your house, and your fuel use patterns and family size, If you buy too much insulation,
it wIll cost you more than what you'll save on fuel.
To get the marked R-value, it is essential that this insulation be installed properly with
pneumatic eqUipment.
Jim
Johns Manville
Johns ManVille Corporatioft
Insulation Group
P.O. Box 5108 ,
Denver, CO 80217-5108
Internet. http'//www,jm com
BIC-194 7197
@ \997 Johns Manv\He Cmporatlor\