HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-10-29
Client
Address
S R Yett
The qlYIlJPlc, L~C
PO Box 2'6125 -
Eugene, OR: 97402
"....""...,.......-
Placement Data
,
:Footlngs for eMU wall at ,front of bUilding In middle
i
;Locatlon Sampled At
:West end of footing
Date Cast 09/28/07 Date Rec'd 09/29/07
;Tlcket No MIX No Weather
- 2987807 30N 170VO Light rain
DeSign Strength (pSI)'
"".,. .
Cylinder No
07 -3348
07-3349
07 -3350
07 -3351
required 3,000
Test Date
Field Cure
(days)
COMPRESSION REPORT
Project No 722-70227,15
ProJ Name Wllco- Olympic Spring
Location
1401 21st St
Springfield, OR
Age (days)
10/5/2007
10/26/2007
10/26/2007
Hold
7
28
28
H
. , --. ,.,
Matenal Concrete
Lab Cure
(days)
6
27
27
.. 1 :' Cone (both ends)" 2 - Cone/Vertical Cracks (one end) 3, Columnar
Remarks
c
Robert Castile
ILO Constructlon- Ilo2@comcast net
EriC Hall Architects
Erik Kunbel
Yardage
Load 1
Total 10
Supplier
Knife River
Slump (In) ASTM C143
Max Aggr Size
.Alr Content ASTM C231
-Air Temperature (F)
Matenal Temp (F) ASTM C1064
Max Temp (F)
,Mm Temp (F)
Specimen Size
Unit Weight (pet) ASTM C138
SPRINGFIELD OFFICE
1040 - A Shelley Street
SpringfIeld, Oregon 97477
(541)746-9649 - (541)746-7163 fax
October 29, 2007 CCB#176269
Date:
B P No
PO No
Cast By.
COM 2007-00-834
Verlyn Bearden
Time Cast
12 20 PM
Field Test Data
6 1/4"
3/4"
68%
540
690
4x8
Cunng Conditions
1 day F C , remainder ASTM
Additives Air
Results Reported To
Dave with Contractor
Compressive Strength Data ASTM C39
placed 3,000
Diameter or Cross Sect Area Cylinder WT Comp Strength Capping Method
DimenSions Max Load (Ibs ) Fracture Type .. Test Tome
(Inches) (s I ) (Ibs) (pSI)
C617 -03 C1231-03
401 1263 80 21,260 1,680 2 951 AM X
400 1257 80 38,020 3,020 3 9 26 AM X
400 1257 80 37,750 3,000 3 9 29 AM X
H
, . '" ,
4. Diagonal wino craklng at ends
5 ' Side fractures (at top of bottom)
, - .
6. Top fractures (same as #5 but end of cylinder IS pOinted)
RlJr&ecttullY ~~mltted,
Pi~Si;J/ ~es Indust"es, I,,"
Steven E Wilder
Laboratory SupervIsor
THIS REPORT is PROViDED FOR THE INFORMA TlON OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT BY ANY METHOD AND ITS TRANSMITTAL TO A THIRD P4RTY BY ANY MEANS EXCEPT IN FULL IS PROHIBITED
WITHOUT THE WRITTEN
\' ,'c "j" PERMISSION OF PROFESSIONAL SERViCE INDUSTRIES