DAILY FIELD REPORT
Date Performed
November 16,2007
S R Yet!
The Olympic, LLC
PO Box 26125
Eugene, OR 97402
Report Number,
722-70227 -25
Client
PrOject Name,
Wllco- Olympic Spnng
PrOject Location:
1401 21 st St, Springfield, Oregon
PO No
Type of Structure
Type of InspectIOn
Permit No
Weather
COM 2007-00-834
Rain
Epoxy
Field Observations and Comments
'Performed continuous Inspection dUring the Installation of (6) 5/8" all thread epoxy anchored bolts In the following
locations west drive through pickup Prior to installation the predrllled holes were cleaned uSing a nylon brush and
compressed air Verified minimum embedment depth of 5 Inches The above listed epoxy anchors were Installed uSing
Simpson Set epoxy With ICC # 1772 Contractor stated the nuts would be tightened after the epoxy has cured The
epoxy anchors were Installed In accordance With approved Job-site plans Contractor was asked to notify our office
when additional services are needed
Inspector Pete Furlong
CCB #176269
If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649
Respectfully Submitted,
ProfessIOnal Service Industries, Inc
~~
Branch Manager
c
Robert Castile
ILO Constructlon- Ilo2@comcast net
EriC Hall Architects
Erik Kunbel
J
THIS REPORT IS PPOVIDED FOP THE INFORMATION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMiTTAL TO A THIRD
PARTY BY ANY MEANS EXCEPT iN FULL, WITHOUT THE WRiTTEN PERMISSiON OF PROFESSiONAL SERViCE iNDUSTRIES, is PROHiBiTED
Professional Service Industries, Inc .1040-A Shelley Street. Springfield, OR 97477. Phone 541/746-9649. Fax 541/746-7163