Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-11-16 l-"~ ;1 Information ~.". .To Build On Engineering. Consulting. Testing DAILY FIELD REPORT Date Performed November 16,2007 S R Yet! The Olympic, LLC PO Box 26125 Eugene, OR 97402 Report Number, 722-70227 -25 Client PrOject Name, Wllco- Olympic Spnng PrOject Location: 1401 21 st St, Springfield, Oregon PO No Type of Structure Type of InspectIOn Permit No Weather COM 2007-00-834 Rain Epoxy Field Observations and Comments 'Performed continuous Inspection dUring the Installation of (6) 5/8" all thread epoxy anchored bolts In the following locations west drive through pickup Prior to installation the predrllled holes were cleaned uSing a nylon brush and compressed air Verified minimum embedment depth of 5 Inches The above listed epoxy anchors were Installed uSing Simpson Set epoxy With ICC # 1772 Contractor stated the nuts would be tightened after the epoxy has cured The epoxy anchors were Installed In accordance With approved Job-site plans Contractor was asked to notify our office when additional services are needed Inspector Pete Furlong CCB #176269 If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649 Respectfully Submitted, ProfessIOnal Service Industries, Inc ~~ Branch Manager c Robert Castile ILO Constructlon- Ilo2@comcast net EriC Hall Architects Erik Kunbel J THIS REPORT IS PPOVIDED FOP THE INFORMATION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMiTTAL TO A THIRD PARTY BY ANY MEANS EXCEPT iN FULL, WITHOUT THE WRiTTEN PERMISSiON OF PROFESSiONAL SERViCE iNDUSTRIES, is PROHiBiTED Professional Service Industries, Inc .1040-A Shelley Street. Springfield, OR 97477. Phone 541/746-9649. Fax 541/746-7163