Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-10-26 October 26,2007 722-70227-18 Wilco- Olympic Spnng 1401 21st 8t Spnngfleld, OR PO No COM 2007-00-834 DAILY MASONRY FIELD KI:.t'UKT l."'!f:;' Information ~~. .10 Build On Engineering. Consulting. Testing Client S R Yetl The Olympic, LLC PO Box 26125 Eugene, OR 97402 Date Performed Report No Project Name Project LocatIOn " Weather Clear MATERIAL INFORMATION SUPPLIER MIX NUMBER SLUMP AIR CONTENT AMBIENT TEMPERATURE MATERIAL TEMPERATURE TIME PLACED NUMBER OF SAMPLES DESIGN STRENGTH (PSI) PLACED liS Performed visual Inspection of reinforCing steel In the locations listed above placement and clearances where applicable D ReinforCing steel was secured uSlnCi SPECIFIC PLACEMENT LOCATION (S) 8" cmu wall Illflll 0' to 7' 2" line A from 5 6 to 5 8, lop out 3 coarser wall line A Ilonl 5 3 to 5 6, and (2) columns at drive througll 0' to 9' 6" and 9' 8" Grout Knife Rlvel 246HG3KOOO 8" Pnsms Mortar 56' 3 00 PM 2,000 3 ReinforCing steel was checked for grade, Size, lap, m ReinforCing steel was placed In accordance with . approved deSign draWings, specifications, and submittal from Hohback-Lewln dated September 18, 2007 detail SK-1 III AII'cells were relatively clean and mortar projections are within the limits of the International BUilding Code II! Performed continuous Inspection dUring placement of grout In the locations listed above D As directed by , continuous Inspection during placement of grout was not required 9 Grout was placed by pump and mechanically consolidated III All cells were grouted solid D Only cells containing reinforCing steel were grouted solid D Empty cells were D Filled with Insulation D Covered with grout paper D Cast set (s) of x ) grout test cylinders D Cast set (s) of x ) mortar test cylinders D Cast set (s) of 0 solid test pnsms D hollow test pnsms B Additional Comments Clean - outs proVided IiIl Contractor was asked to notify our office when additional services are needed III To the best of our knowledge, the work Inspected above was In accordance with the building department approved deSign draWings, speCifications and applicable workmanship prOVIsions of the International BUilding Code, except as noted D ReqUires Engineers Acceptance (RFI) ICC #0877340,84 OBOA #442 I Distribution List Robert Castile ILO Constructlon- i102@comcast net Enc Hall Architects - annette@enchallarchltect com Enk Kunbel D Non,Compllance Inspector DaVid Smith Respectfully Submitted, ProfeSSIOnal Service Industnes, Inc CCB #176269 Revlew~d'~y '~/ ~ ~r~, EIT Branch Manager D Re-Inspectlon ReqUired THIS REPORT IS PROVIDED FOR THE INFORMA TiON OF THE CLIENT ONL Y THE REPRODUCTiON OF THIS REPORT BY ANY METHOD AND ITS TRANSMITTAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL IS PROHIBITED WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES ProfeSSional Service Industrres, Inc .1040-A Shelley Street. Sprrngfleld, OR 97477. Phone 541/746-9649. Fax 541/746-7163