Engineering · Consulting · Testing D AI L Y FI E LD RE PO RT
Date Periormed: October 18, 2007 Report Number: 722-70227-16
Client. S R Yett Project Name: Wilco- Olympic Spring
The Olympic, LLC
PO Box 26125 Project Location' 140121stSt
Eugene, OR 97402 Springfield, OR
P.O, No.: COM 2007-00-834 Permit No,'
Type of Structure. Weather, Showers
Type of Inspection: Masonry
Field Observations and Comments
. Performed visual inspection of reinforCing steel In the follOWing locations CMU wall Infills west end of North wall Line A
from 4 to 4 5 and 5 to 5 5, 0 to 9'10" above footing Reinforcing steel and anchor bolts were checked for grade, Size, lap,
placement and clearance where applicable ReinforCing steel was placed In accordance with approved deSign draWings,
specifications, and revised detail SK-1 dated 9/18/07 All cells were relatively clean and mortar projections are within the
limits of the Uniform BUilding Code Performed continuous inspection dUring placement of grout In the locations listed
above Grout was placed by pump and mechanically consolidated All cells were grouted solid Note Clean-outs
prOVided To the best of our knowledge, the work Inspected above was In accordance with the building department
approved deSign draWings, speCifications and applicable workmanship provISions of the Uniform BUilding Codes
Contractor was advised of all on-site tests results and was asked to notify our office when additional services are
needed
Tyoe of Material
Supplier
Mlx#
Slump
Air Content
Ambient Temperature
Material Temperature
Time Placed
DeSign Strength (psi)
Number of Samples
Total Yardage Placed
Inspector' David Smith, ICBO #0877340-84
CCB# 176269
Prisms
Knife River
246HG3ROOO
8"
57"
620
1 45 PM
1500
3-12",3-8"
50
If you have any questions regarding this report, please feel free to contact us at 541-746-9649
Respectfully SU,bmltted,
Professional Service Industries, Inc.
~n~
Branch Manager
c: Robert Castile
ILO Constructlon- 1102@comcast net
EriC Hall Architects
Erik Kunbel
THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PAAiIJS'sllJMtJglM!1M9SI~fle1J'/ ffil-t., m46QVslJI~rsfrgftii"~~(8I'cl,ct5Pf@~~5'4'1W4!l'~9"IEfSa~Wtl6l79163