HomeMy WebLinkAboutPermit Field Test & Inspection Report 2005-7-12 07/12/2005 02:59 5038972013 INDEPENDENT PRESS PAGE 02 \l\~ 5q4h ~,- Independent Inspection 978 SW Hall Avenue Mill City, Oregon 971fJO I 503 897 3269 Page ()t Daily Field Report High Strength Bolting Project: All Pro Machine Date: June 12,2005 Job Address: Springfield, OregOIl Client: Oregon Cascade FabricatJon Eugene, Oregon Pe..mit Number: Amended Renort Weather: Temp: Time Arrived: Time Departed: Inspection Site: This is an amended renort to the June 26. 2004 Insneetio": Inspector was called to perform a h1gh strength bolting Inspection to the already assembled building located at the north side of the lot. Observed I Verified: Reviewed the approved drawings and contract speclflcatJons. Venfied that all faymg surfaces were in contact and performed a torsion test to J 5% of all bolts at various conncctlOns to verify bolts were ten~ioned to the correct compressiOn. Verified that aJl hoh~ were of the ASTM A-325 as required Inspection Compliance: InstallatlOn of the ASTM A-325 bolts comp]ie~ with cnteria set l'orth by the me, the contract documents, and the AIse. NOTE: Due to retuemenl my leBO certlficatlon expired as of June 30, 2004 Inspector: 1 If ~ <:to ~- A_'i/cC'-'1 Certification No.: CWI #98-010981/lCBO # I ()79292-851 cOP #713 / OBOA #3961 WABO HAN-36-0793 These test aod Inspectu:1n results relate Gilly to the specific test locations !luted. Inspector IS not responsible f()~ BOY other IOC8tl01l or clevati()n. Reports may not be reprodul;ed, e~cept In full. Without w~ittcn pe~lnlsSlon of Inspector