Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2002-10-7 FRQI"I : FAX HO. Oct. 07 2002 04:41Pf1 P6 -I .. CummullIty ServlLes Div, Buddjng Safety CITY OF SPRINGFiELD; OREGON 225 5'" Street., Springfield, OR 97477 'Ph. 726.3759 Job Address City Job # ~r.., ~SA.O Ir;>:'a :;V~:~_i .i'~ ~~ ~:~1 :..~':~i Sj~~t:~~i:.~1~:. ~~~~~?~ ~,~"\!.. ~:;.; +., .1~~~/~;~~..,:'j,:,,,",;"J ;. f" ':';:i:i: ~~.: .~: ~~t;f1'~ ~t~~~~'...:~;~~ '; Affidavit For Site Investigation Questionnaire Foundation Sub-Grade Approval for Residential Building Site in Ambleside Meadows - 1st Addition Subdivision The undersigned hereby afflIr.'lS that the excavation. structural fill and moisture stabilization methods for the building site at the address shown above was observed by me or an authorized employee of my fum and that the following is tme: 1. The foundation sub-grade is capable of supporting a minimum of 1.500 psf, and is adequate tc support the building proposed for this site. 2 The mOisture content of the excavation was adequately maintained during the site preparation process and was adequately covered to stabilized moisture content .l;'J.~~'J. to any significant change in moisture content of the sub-grade. 3. The site is adequately graded and drained. to prevent the collection of water in the excavated area during construction. 4. . t~~ Date t~ 10 t.- Name of Licensed Professional (print) n SignatureJ~ ' I " > ~ f.XflJ~'FI::;I~ ti':;lc: v/0Jioal FRGr'l : FAX NO. Oct. 07 2002 04: 39Pt1 P2 CCJI'l1muni!y Services Div, BUIlding SAfety CITY OF SPRINGFIELD, OREGON 125 Stl1 Street, Springfield. OR 97477 Ph. 726-3759 Job Address 1. t. (, '" City Job # '?~' e.A AMBLES IDE MEADOWS SUBDIVISION-1ST ADDITiON Site Investigation Questionnaire for Consulting Design Professionals foundation requirements ~ new structures on residential lots This form may be used as a temporary verlticatioD to allow COll1Struction to continue on the job site until the consultant's stamped aftidavit on the site soil compaction and stabi.lizatiOD is submitted to the Oty. This f'viL.i.U must be c.ompleted by a licensed design professional (engineer or archltect) or hislber authorized employee, and submitted to the bunding inspector prior to requesting City inspections or plaeing foundation concrete. It is important that all questions be answered completely for the foundation site to be approl'ed fo:.. construction. Owner and/or Contractor ~ '2.'1 1. Date of the design professional's site el'aluation? 1d.PM.&;7S ~'- 7 ~o e,c..T' 4. I 2,.e:l 0 'Z.. 2. Has the dCfjign professional reviewed a copy of the geotechnical information for the subdivision that was provided with the building permit? YesJ<.No_ If not, please con.tact this office for a copy vf the report. The design professional must b~ familiar with th~ geotechnical information before completing this fonll. 3. What was the size and depth of the excavation and lor fill? 'L 'ZhEJO b Was existing non-structural fill or expansive soil encountered on the lot? Yes_NoX If "yes", what types, depths and locations? What measures were taken to remedy the soil COPf}ti.'on (include type of engineered fill used to stabilize the soil)? fJ, ~ 1 FRQM : FAX HO. Oct. 07 2002 04:39PM P3 CornmunllV Service:; DIY. Buildmg Safety Job Address 'to ''It/,p(.,, CITY OF SPRINGFIELD, OREGON City Job # 225 S!h Str",e(, Springfield, OR 97477 Ph. 726.3759 ~~ p? Is the site as prepared adequate;@. inadequate 0 to maintain constant moisture content in the sub grade? Note: Verification ofmoislure stabilization in the sub grade is a requirement of the geotechnical repon. and must be affirmed before construction can continue. If inadequate, what measures are needed to provide constant moisture content in the sub grade? Is the site as prepared adequa.te J'L in.adequate 0 to support the l'w!'u.:Jed structure? An atfinnative an.wer is requisite to proceeding with construction. H inadequate, what additional work is needed to provide adequate foundation support? 4. Did the design professional witness placement and compaction of the 'f..J I ~ engineered fill, or is there a special inspection report forthcoming from a qualified agency? I witnessed Placement 0 Speciallnsplcompaction report 0 5. The design professional intends to use the :following method for installation of perforated perimeter footing drains: The design on the attached drawing provided by the design professional..... . 0 The method shown on the original construction drawings......................... 0 The t"fPical 'Foundation Drain' drawing attached to permit ..................... 0 Perforated perimeter drains are not required.... . . .... . . ... .. .... . ... .. ... ........ .:a.. Comments: Note: City inspec:tors will inspecr installed drains prior to cover upon request... Call: 726-3769 ttJ schedule i.llspeczion. 2 FRQM : FAX NO. Oct. 07 2002 04.40PM P4 Communtty Services DIV, Buildjn~ Safety CITY OF SPRINGFIELD, OREGO!\; 2255<11 Street., Springfield, OR 974"17 Ph,726-3759 Job Address "L-z...,~ City Job #_ ~~ ~ Low-point crawl space drains are required to prevent the build..up of excess moisture inside the foundations during (and after) construction. This drain may be installed ~ foundation placement onI'\' with the .~resspermission of the desi~n prof~~iomd~ a. The design professional has determined the following; The crawl $pace drain is required when thefoun.dation is installed. ." 0 The low-pomr drain can be installed a.fter foundation placement without a significant moisture bllild~up problem within the foundation............. ~ (The low. point drain may be installed at the _ ,;6.a ~ "11 .stage of construction) past &: b=m.jmmJng. roofing, tttc. b. Has the d~sign professional observed and approved the installation of the required low point drain?.. ................... .............. Yes,_. No,.)<.-.. if 'yes'~ where is the low point drain located UJUler tlu:. building and where does it terminate at this time? (must be an approved location, i.e. street gutter, storm sewer, Skmp pump and discharge line to the street, etc.) The des1gn professional must detennine whether the approved pennit drawings have adequate foundation steel. Is any additional foundation steel required that is not shown on the foundation drawings for the building? Yes x.. No . If 'Iyes ", describe additional steel required (or provide drawing). The following starement must be signed by the individual doing the observations and providing directionfor the e.tcavation and site preparation work on the property. 3 f"RQM . FAX NO. Oct. 07 2002 04:40Pt1 P5 -" Community SerYl<..es Diy, Buildmg SafelY CITY OF SPRINGFIELD, OREGON 225 5!~ Street, Srrjngtield, OR 97477 Ph. 726.3759 Job Address City Job 1# ''"If'L lP " '3 'b 'tV' The undersigned design professional (or authorked employee) attests that he/she observed required moisture stabiliJy procedures on this site1 and that such procedures were accomplished before any changes occurred in the moisture conten.t of the sub. grade uruler and around the building (where expansive soils were encou.ntered). The undersigned further attests th4t the sub~grade, as prepared1 I's adequate to SUpport the building proposed for this site. Additional conunents: (Note): A copy of this report shan be kept on site with the approved plans at all times. This report shall be followed by an affidavit, signed and stamped by the design professional under whose auspices this report was completed~ affIrming the infonnation herein. The signed/stamped affidavit together with a copy of this report shall be submitted to tlus office.rrior to requesting framing inspection for the building. Signature \l~~ . \.t------ Name e.ta.::. /2J..~p~ Title ervh ,t.~ . Company K btz. T t t;T2. -e t-3&,. L'1 ~ En... Phone ~'-I'" 3&f'-:::a, Licensee License # P A.M..l;;l..A . ~!:t-'.r u- P E- "SP W:l\\~-t-~M. p. B. _ expires (.1 ~~/<' ~ The geotechnical report for the Ambleside Meadows _ 1 st Addition Subdivision recommends immediate moisture stabilization of exposed expansive sub-grades. and tbat expansive soil~ be over~excavated mid replaced with at least 12 inches of fill compacted to at least 95% of ASTM D698 for foundation preparation. The report also recommends that measures be taken to prevent water from collecting in or around the foundation areas during and after the construction process, and that positive site drainage be provided to reduce the infiltration of surface waler into the expansive soils. The geotechnical report further emphasizes that the finish grade of landscape soil adjacent to the foundation should be at least 24n above the expansive bearing soils, f1.11nh: comoacted to reduce the infiltration of Water at the sUIface. The adequacy of fIll soil material around the building must be verified to the satisfaction of the design professional. 4