Loading...
HomeMy WebLinkAboutPermit Building 2006-9-7 . . CITY OF SPRINGFIELD Building/Combination Permit 225 Fifth Street, Springfield, OR 541-726-3753 Phnne 541-726-3676 Fax 541-726-3769 Inspection Line ~ , PERMIT NO: COM2006-00844 ISSUED: 09/07/2006 APPLIED: 07/07/2006 EXPIRES: 03/07/2007 VALUE: $ 4,502,367.00 Status Issued SITE ADDRESS: . 505 Main St ASSESSOR'S PARCEL NO.: 1703353110400 Springfield TYPE OF WORK: Apartment Building TYPE OF USE: New PROJECT DESCRIPTION: Royal building - 5 story residential and commercial building Commercial Owner: A.ddress: ST VINCENT DE PAUL SOCIETY 705 S SENECA EUGENE OR 97402 Phone Number: 541-687-5820 I CONTRACTOR INFORMATION I .\,::::,'<;" ~ Contractor ~",,' ~\) ANNE DELANEY ,i '\~" f.> ~ MElLI CONSTRUCTlON'CO,\) ,\.J" ("\'(.' <~"\) BUILDERS ~~~<:I~BI~\!,NC HOME COMFORT HEATING & AIR' .\...'\\ < '<' <"\Y" ~9Blt'I$O~~.t:"'1,JMBING INC 1071~4 .....f;;;,,,\"~'v~~'v\) ~ \)~ ~I: BUILDING INFORMATIONI~"" ~ "'~~<:o <;::,~ <;..,<,::-",,<:<,<'::-. .~<z,'? ~v'~'Or:," # of Units: '\ . ,,\~ ...:5v~ \J~ # of Stories: d' n& n"'e, ,/J5'Q"" Lot Size: . """, ~". 0.'0 . .'<i ~V' ~v co,. .., Primary Occupancy Grou~;~ 'U R2 HeIght ofStru!:.tur~Ci '" ~ ().. 6~,.00 /~ ~q Ft 1st Floor: Secondary Occupancy GrouI}i~ M Type of Hea(I' xs:' <.:~<z,. 0' E;,1~ctricV ._.Sq Ft 2nd Floor: Primary Construction Type IA Water TY,y';:/.)'Q""o"'<z, ",2$' I':le~tric. Sq Ft Basement: Secondary Construction Type: V A Ran~~~'f,yg!:? ,,'<::' ;{i-O r::/;-~~Iee!rie ;-" Sq Ft GaragelCarport # of Bedrooms: Energy,Path1" ,<::) do> ,c!,' Path I.' Sq Ft Other: Sp~inKI.rd(B~i1ding? ~~ \~ "'~'-~l1j'/~ Occupant Load: ;(X/ ".s- _ \,) ,,": ~ J ,.,' o,J" License Expiration Date Contractor Type Architect General Electrical Mechanical Plumbing 63771 4296 84164 02/12/2008 12/10/2007 06/25/2007 07/13/2007 PhDne 541-683-8661 541-485-1417 541-485-0922 54] -345-2838 541-345-6909 7,865 7,865 22,710 172 Front yard Setback: Side I Setback: Side 2 Setback: Rearyard Setback: Solar Setbacks: I Dc. cLvr.tvIENT INFORMATION I . ~v........ :v 'J ~Y' ~ _'.0 0'("" ..,0 .~' ,'" ,,' ,,- f'\. ...c~ ,..0 ~e; Ove.rlay Dist: V 'C,,-" ("\V n.' '{"j , # Street,Trees Rqd: v' Paved Drive Rqd: % of Lot Coverage: REQUIRED PARKING Total: Handicapped: Compact: I PUBLIC IMPROVEMENTS I Street Improvements: Storm Sewer Available: Special Instruction: Sidewalk Type: Downspouts/Drains: Notes: Pa!!e I of6 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone' 541-726-3676 Fax 541-726-3769 Inspection Line Description Estimate Tvpe of Construction Estimate Fee Description Plan Review Comm/lnd/Public Plan Review Fire & Life Safety -Mechanical Issuance Fee- + 10% Administrative Fee + 100/0 Administrative Fee + 8% State Surcharge Addressing Assignment Backnow Device Building Permit Exhaust Hoods Fire SF Fee - Non-Residential Fixture FLS Safety Systems Review Furnace - up to 100,000 btu Plan Review Plumbing (30%) Sanitary Sewer - Improvement Sanitary Sewer - Reimbursement SDC MWMC Administration SDC MWMC Improvement SDC MWMC Reimbursement SDC SanitarylStorm Admin SDC Transpo Admin SDC Transpo Improvement SDC Transpo Reimbursement Total Amount Paid . I Valuation Descriotion , $ Per Sq Ft or multiplier $1.00 Square Footage or Bid Amount 4,502,367,00 Total Value of Project Fpp,. PiWU Amount Paid Date Paid $9,669,01 $5,950,16 $10,00 $6,00 $2,140.89 $1,468,11 $31.00 $14,00 $14,875,40 $684,00 $3,057,50 $2,310,00 $60,00 $468,00 $90,00 $1,766,31 $2,322.87 $10,00 $22,682,95 $2,150,35 $982,87 $585,57 $1,986,00 $450,25 7/7/06 7/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 9/7/06 $73,771.24 I Plan Reviews I Paee 2 of6 . CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2006-00844 ISSUED: 09/07/2006 APPLIED: 07/07/2006 EXPIRES: 03/07/2007 VALUE: $ 4,502,367.00 Value Date Calculated $4,502,367,00 $4,502,367,00 07/07/2006 Receipt Number 1200600000000001029 1200600000000001029 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 2200600000000001250 . CITY OF SPRIr~url":LD Building/Combination Permit PERMIT NO: COM2006-00844 ISSUED: 09/07/2006 APPLIED: 07/07/2006 EXPIRES: 03/07/2007 VALUE: $ 4,502,367.00 :-S~G'I!!I~.iij ~- .~..... . Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Fire Department Review 09/06/2006 09/06/2006 OK GRG Fire Department Review 07/10/2006 08/30/2006 OK GRG Initial Review 07/10/2006 07/10/2006 APP LLH Plan Review Comments 08/09/2006 10 JMP Plannine Review 07/10/2006 07/26/2006 APP EMM Plumbine Plan Review 08/22/2006 08/22/2006 OK SKG Public Works Review 07/10/2006 08/02/2006 APP SB Revised Plan Review - Fir 09/05/2006 09/05/2006 OK GRG Paee 3 of6 Plans Review: Stuh up for future sprinklerlstandpipe assemhly for Royal Building, Job #COM2006-00844, Designer: Mike Tennant, Contractor: Omlid and Swinney, Plans appear to meet code requirements. Note for plans: City of Springfield Building Department has changed the address numher for the new building 10 505 Main Street, See attached comments for Fire Department Plans Review comments. WE, See attached document for cover for 3 electrical comments faxed to Anne DeLaney. LDAP Issued, Addcd SDCs. Plans Review: SI. Vincent DePaul Royal Building-main structure (Phase II-2nd revision-supplemental), Job #COM2006-00844, Occupancy Classifications: A-2, B, M, R-2, S-1. Construction Types: 1st noor: I-A Sprinklered; 2nd through 5th noors: V-A Sprinklered, E-mail from Robert Castille, City of Springfield Building Inspector to Anne DeLaney, Architect for Bergsund DeLaney Architecture and Planning asking for firelsmoke damper submittal. Submittal shows fire smoke dampers on 2nd through 5th noors, Fire smoke dampers shall he monitored by the fire alarm system, . CITY OF SPRINGFIELD' Building/Combination Permit PERMIT NO: COM2006-00844 ISSUED: 09/07/2006 APPLIED: 07/07/2006 EXPIRES: 03/07/2007 VALUE: $ 4,502,367,00 . Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Revised Plan Review - Fir 07/25/2006 GRG 08/31/2006 OK Revised Plan Review - Pia 07/25/2006 07/26/2006 APP EMM Revised Plan Review - Pu 07/25/2006 Revised Plan Review - Str 07/25/2006 07/25/2006 10 JMP Revised Plan Review - SU 07/25/2006 Structural Review 09/07/2006 09/07/2006 APP JMP Slructural Review 07/10/2006 07/19/2006 WE JMP SUB Review 07110/2006 08/17/2006 APP JF Addendum I. Plans Review: St, Vincent OcPaul Royal Building-main structu rc (Phase II-1st revision), Job #COM2006-00844, Occupancy Classifications: A-2, B, M, R-2, S-1. Construction Types: 1st noor: I-A Sprinklered: 2nd through 5th noors: V-A Sprinklered, Additional emergency egrcss lighting shown on Buildcrs Elcctric Plan Sheet E2-firsl noor north egress and lobby arcos, Will verify on inspection. Addendum I Addendum I WE, Addendum I. Addendum 1 Received responses to structural comments and final internal approval. See attacbed documents for 7 structural comments faxed to Anne DeLaney, Using SUB's incentive program, To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m, will be made the following work day. I RP"IIWlrf In<.nprt~ Site Inspection: To be made after excavation but prior to setting forms, Erosion/Grading Inspection: Prior to ground disturbance and after erosion measures are installed, Rough Plumbing: Prior to cover and including required testing, Final Plumbing: When all plumbing work is complete, Rough Mechanical: Prior to Cover Final Mechanical: When all mechanical work is complete, Rough Electric: Prior to Cover Final Electric: When all electrical work is complete, SUB Insulation Vapor Barrier: To be called for at the same time as the SUB framing inspeclion, SUB Final: After all required energy inspections bave been requested and approved, SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover, Paee 4 of 6 ~~-;'.,. ~... . . CITY OF SPRINGFIELD' Building/Combination Permit PERMIT NO: COM2006-00844 ISSUED: 09/07/2006 APPLIED: 07/07/2006 EXPIRES: 03/07/2007 VALUE: $ 4,502,367.00 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SUB Ceiling Grid: Interior Lighting SUB Exterior Lighting Ufer Electrical Gronnd: Iostall gronnd rod at footing and call for inspection in conjunction with footing andlor foundation inspection, Footing: After trenches are excavated. Foundation: After forms are erected but prior to concrete placement. Slab: To be made after all inslab building service equipment, conduit piping and other equipment items arc in place but prior to concrete, Shear Wall Nailing: Before covering sheathing with finish materials, Framing Inspection: Prior to cover and after all rough in inspections have been approved, Wall Insulation: Prior to cover, Ceiling Insulation: Prior to cover. Roofing: Prior to installing any roof covering. Firewall: Located and constructed according to plans, Masonry: Bolts Installed in Concrete: To be done by a State Certified Special Inspector, Provide inspection test reports to City Building Inspector. Structural Concrete: In excess of2500 psi, To be done during construction by a State Certified Inspector. Provide results to City Buiding Inspector Roof Sheathing/Nailing: Before covering sheathing with finish material. Glu-Lam Beams: Inspection Certificate by an approved agency to be provided to City Building Inspector prior to placement. Ceiling Grid: After dl")'wall approval but prior to cover, Hold Downs Installed: Special Inspection performed prior to placement of concrete, Provide report to City Building Inspector, Epoxy Anchors: To be done by Certified SpcialInspector. Provide Inspection results to City Building Inspector, Structural Welds: To be done during construction by State Certified Special Iospector, Provide inspection test results to City Building Inspector, Final Fire Department. After all requirements of the Fire Department have been met, Final Building: After all required inspections have been requested and approved and the building is complcte, Rough Grading: After gravel is in place but prior to placing concrete, Final Paving: After paving is complete. Underslab Plumbing: Prior to filling the trench and including required testing, Paee 5 of6 . . CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2006-00844 ISSUED: 09/07/2006 APPLIED: 07/07/2006 EXPIRES: 03/07/2007 VALUE: $ 4,502,367,00 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line I I I By signature, 1 state and agree, that 1 have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and 1 further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety, I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all "om '"ri'~i'~ ~ r, "if>>~ 0.... o.t'''m~m ,;,..'1tt- 0'" Paee 6 of6 ~u o..i. '" I/) '" o o o o o I/) .... o ~, -. o. Ui,. -, " . ~~ ~~ ~, o. Ui,. -, - .. .. "- .., .. <> ('fi C'1Iy of SprinefieJd Cornmomily S...ices DMsion 22S FifiIJ 5_ Si>"in~ld, Oil 974n T~: {54I} 726-3759 Fu.: (541) 726-1689 Cb M "Z..<<lC> C:. - eo 8 "Z.. ~ Bui.Idiqj P..... ~ . -rH~ ~YAL,.... PIojecl rill. 'i)oS HAHJ -:~E.T"' Proj<cl Ad,!,... .,. "t.o,oC:. 0.... 1?::>L.~. z ~ ... g T.appi..... .rf'8i_ "'1Uirirw -~ mpa,ion ................S.dian 11IoIofdlo ~su..:n.... S...'illIIyCod. 1'1_ p<yi,,,fIlc -......_. 1II_,...Jw" lftisln...mo..b!ro..,..... . . ~q:oIlbe ;"C-.....llysipi..klo"'._murnllN _,.... CiJ~. BlrolUr A PBlUoIfTC''''' 81 ISliUI:ll: TIIo__.._., _.....;..... .....'M.oo...h, "'_........&p.a:,.. ,\r<IIi..... _I'....,.d., ~li"o.....""...il...... a", tQ'~i'.tIlda,~ diu formrOZ'Plplelrdealle1b lib _I udhcl no ....,,"..,.,Gc_c.e..a01. _. "Wli""... JhaJ'oI...........I<d.. ollo COllD_..,.. .. .. '. ...,,;.-.. Sp:....lN,..tiao ""*,,,T..,jog. SpecioIlarpectioor .... TffliDe . '" o o ~ .... - ~ ... I. c.'_j, l<tpcadllloor.,. _notili..... rv....Ilupc<1ioawT...q,.ri.....1iasL 2. T.,lMa "'_1101)' -...., "",,","a, '-plt.... . ,,,,. ......,.Ita:~ _...." ... _'" -..i..... ""'"'" · CopiaofolJ -lDJ'_u"-,,,,,, II' ..be_....Cilylly.... TUIio:AII'll<JI, ..J ~ - z o :E ~ ~ L .., ~ ~ . - '" ~ - '.. J. S.......I..."i... ~ is '" "'bm~ "'.... D4 qaoIillc1llJOlllI or..... Sf..... 10........ .. rIw ul)' r., _.... 4. SpccioI,._ - provide WP<d..._.......""illincolli<i.. .raUimpuJi.......<ilic:s. So C_...., is _n_hk 10 m;.-.... C-1Iy '., , .: pIouliroddili""'I...~...., laIi..IUl..;'_lhalmo,....1M ..roU4 CKRn11CA11l or OCCUPAIlC\' WILL "I.IS~ID: Th'~;'1 fJlSjl<CliDll "-_ ,1IaI1 MIo;'" tIie 8oil~ orncc. ._....."'" all ;'..... ~'1 j_..",.. bee.. fidljf1ed an.! ",",.ed.... --- '" ltI. 6cJl orchc i_l..,.Jooo.n;IaJ:o, in .""'_,..i1b dot _'04 pia... Jllft:i__ .........l~_...... ". ::. ,S ..,.. ;,"". -'ured_o'Wp.t1c4_b...-........-..- Tho .......is..""..bot.i..~"'dreCilyjOior ..._IO'r...j.......,..,.. ~ ~ . ~ ~ t: . L~ J J ::: J ~ ) - .. ) .. , ~ "- to. 0_ AClCNOWl.EDGBMEHrs ~,V,'ru..d' -k- ~ul___ t1.~IL( C.t:1~rFtvc.nD~_ o...u "'-<: (Pti.led) ~o.m", si&naAt.. , 0.0. lAJ_lllr Finn Home ~ ~oh!x:lc.J,- Le.l.4.>in _V~ ~ .r~1 _ ~..................~'A ';:/i:::~-' ~-'~~ ~';"; T"*'l LaMlra!OIy Na., O'>inled) T..,;", LobcalOfy~. SiglJaturc Bu~ti.tl NIIrI. (Prlid';') tJr~.L . Gcmnll c.........r si........ ~~.I.;;,;~~ ~~ "::::..... ~ ". - g lMidin~ Si.Pl1Jlre '" . "- h .. ~; I':ll:: ,. ".\ lL '" OJ' < ~ <:> <:> .... ~ <:> <:> S SPECIAL INSPECTION Ai'll) TZSTING SCHEDULE I Reiafooced Cancrt1e, Gunite. Grout and MoJ\;U: i eon",,'e _l Guorlle I Groot I Morw I -tHJ<.i I I "" I I ; Ae~~c TC5t of Mix Dcsillttl I Reinbci~ Test Mix Dcsi Wei!hmastec Ccrt.. ReinlomM Pla<emenl i Corninuous B..cI1 PIIIIlIIMDcl:I. i I"'''''d Pb:iIl. I Cs SaDDles r S.1JDolcs (Pick\lD'Delivcrml I COl1llK'eSSion Tat. ..... GRADING,EXCAVATlOi'l,A.IIDnLL lpt'f" '3t:Q\1n1\'1lC~ Acceptance Ie..... I'SF en5' neeV' I Eotohlisb final gr.de ~ Fill ptacancn. inspectioo/CllIl.inUOllS X. Soil Dcn.i.ly ~ u'tS ~AADC ~T R u...- ~ ....l '" <:> '" . STRUCTUJlALSTUUWKLDING: Ul'IItl.eml.:lS'l Sampl.ondlest(lisI.peciflcme.......bclowll ">e"'kIer .-) Shop moleriaJ ideotifio:a1ion (mill <<rtl \Yeld inspection ~Shop L.Fjel~ UI1rasomie inspect;o. _Shop _F",I~ High Slrtusth Bollillg_Shop _Field A325 _N _X A490 N X Mellll deck '''''!ding imjl<l:lion - Tteinrortin: Sled wcJdirI: iaspectitm Rcinfon::ing.:StJ:d mill cenifiClIe MctnJ stud \Y~Jding inspection Conaclc insert welding inspection Moment relisJ:ing stetl m.ne, (;1J 1 Pm:..up~""esscd Com:n:le: Pit.. Post- T '''1 Pr.~r ens ~j ':~ I Oaddi.. _F _F .~e~c Te.... R.c:inlorcmE Tests Tendon T cst Mix Desi.p.ns~ Rcinforci02 PJacmJm ''''''11 PIac",""" Concrete Batcllin2 Cancrck 'PJart:ma'lt lnslatlation In.tpettion '(;Sam.l.. J Pidc-UD SDmo.!c:S I Camoressian Te.!ts STRUCTURAL WOOD: Shear \w..Il D~iling inspccrlon Sh<... ...11 arn:hor. ~ InSjJCdion af GIIl-lam fab.' 4'- TIC.,.i ~ Inspection or truss joist fab. Sample and test c." 'I' ,..,Js Fabrication "'l:Jding ohtcd ....'"I:cs:5orics x .., '" '" )c.. y " "' .., -< -< .., 00 "' -< ~ on SMOKE CONTROL, . Lenlcage lUting .Control Verifiaion MASONRY ;>< Spccialif\S!lCl:tion_...d.~l'm-*-rg Preliminary accepcaoce tots (masoa.ry units, Willi prisms) Snbscquen.1csts (marlar, groul, rldJ w.1I prisms; X PI~cmenl inspc:ctionof\miu. and reinforcement Masonry, mortnr. gl'OU(, and reinforcing steel ccrtifLC:J1eS FlREPROOJllNG: Placerci:nI: impa:lion Ikmity tc.sls Thickness tC1t$ I""pcct holdling ROOFDlG, In.snfafioD i~h1ttonlR-VoJuc. Trn.stri""'<1IIJ\' ~ "" ADDITIONAL INSRUCI1ONS, OTHER TEST. '" INSPECIlONS: i) ?r-oVld!":. ~\o..e Ih~C.tl"'" .for'" \'"Od.~ -;e-\- in ').') ~ioJI \~c.,~ilM~ -to be.. CJ1'(l\-\VI\.4QU!:> nn\'i C.nClD~V" \ 7 . Form CumpJet.cd hv- f;:po)<'1' (Oe.A.. \(L ~DOyb ) uMevI"_ ~ec.\ hrl \~ \ ~ ht;Gc.. .., .., . 0... .. 00 o "' o o .. .... <- -< ......:-.. <- o _ 'PROVlDE STRENGTH REQUIRED BY ARCJlrrKCT OR ENGINEER OR CONTRACT DOCUlrlENT LOC\ TlON OF VALUES . L pep.. ~TU~I... ~~e co 1-\ ee..T Si,O" " m ..... ..... ... '" ..... '" m m '" m '" .... '" ..... . n .... -I < o ." r.n :ll . f!! " "U 1> Gl fTI m '" AlTACHMENT A CITY OF SPRINGE SYSTEMS DEVELOPMENT CHARGE WORKSHEWffective I Julv. 2006) JOURNAL OR JOB NUMBER CO 0844 . NAME OR COMPANY: St Vin=t de Paul- Roval B1do LOCATION: 505 Main St MAP & TAX LOT NUMBER: 17 03 35 31 10400 PEVELOPMENT TYPE: _ Mid-rise "P'"J""~~~33) with G..___;a1 e'"e-', below NEW DEVELOPED AREA (S.F.): 33.00 Mid Rise Res. NEW DEVELOPED AREA (S.F.): 4,136.00 Specialty Retail EXISTING DEVELOPED AREA (S.F.): 6,600.00 Discount Store EXlSTING DEVELOPED AREA (S.F.): 2394.00 Office TOTAL IMPERVlOUS SURFACE (S.F.): 8.604_ STORM DRAINAGE LESS NEW IMPERVlOUS IMPERVlOUS SQ. IT. x $ 0.336 PER SF i....,.-' ~ ITE: ITE: ITE: ITE: LOT SIZE (S.F.): 223 814 815 710 8604 TOTAL STORM DRAINAGE SDC:Lu 81 = '8 ~ ~ ~ "' H .: ..t. u 8 " .1ii E- " o ~ il! $0.00 I $0.00 1178 2 SANITARV ":,~V"l=~ A REIMBURSEMENT COST: NUMBER OF DFU's 357 B. IMPROVEMENT COST: NUMBER OF DFU's 357 (SEE REVERSE SIDE) Downtown Dtvelopmcnt Cndit (75".) x $ 26.03 PER DFU x $ 19.79 PERDFU $ 45.82 TOTAL WCAL WASTEWATER SDC:' 3 TRANSPORTATION BLDG AREA TGSF x TRlP RATE x COST PER ADT x NEW TRlP FACTOR NEW A REIMBURSEMENT COST: 33.00 x 6.59 B. IMPROVEMENT COST: 33.00 x 6.59 NEW A REIMBURSEMENT COST: 4.14 x 44.32 B. IMPROVEMENT COST: 4.14 x 44.32 EXISTING A REIMBURSEMENT COST: -6.60 x 56.02 B. IMPROVEMENT COST: -6.60 x 56.02 EXISTING A REIMBURSEMENT COST: -2.39 x 11.01 B. IMPROVEMENT COST: -2.39 x 11.01 x $ 19.81 PER TRlP x NTF NTF 0.75 NTF 0.75 NTF 0.65 NTF 0.65 NTF 0.9 NTF x $ 87.39 PER TRlP x x S 19.81 PER TRlP x x $ 87.39 PER TRlP x x $ 19.81 PER TRlP x x $ 87.39 PER TRlP x x $ 19.81 PER TRlP x $ 87.39 PER TRlP $ 107.20 TOTAL TRANSPORTATION REIMBURSEMENT SOC:' TOTAL TRANSPORTATION IMPROVEMENT SOC:' DowntowD Development Credit (7S./.) TOTAL TRANSPORTATION SDC:~ 0.9 NTF x x $9,291.47 1 $7,065.23 I SI6,356.69 I $2,322.87 $1,766.31 $4,089.17 $4,308.56 I $19,004.751 S2,723.791 $12,014.46 1 ($4,76l.38)I ($21,002.12)1 ($469.99)1 ($2,073.08)' $1,800.98 I' S7,944.01 1 S9,744.99 1 $ $450.25 S I ,986.00 2,436.25 4 SANITARY SEWER - MWMC NEW: A REIMBURSEMENT COST: NUMBER OF FEU's 33.00 x S70.31 PER FEU $2.320.32 ~ B. IMPROVEMENT COST: NUMBER OF FEU's 33.00 x S741.69 PER FEU $24,475.87 I NEW: A. REIMBURSEMENT COST: NUMBER OF FEU's 4.14 x $23.44 PER FEU $96.94 I B. IMPROVEMENT COST: NUMBER OF FEU's 4.14 x $247.23 PER FEU $1,022.55 I EXlSTING: A REIMBURSEMENT COST: NUMBER OF FEU's -6.60 x $23.44 PER FEU ($154.69)1 B. IMPROVEMENT COST: NUMBER OF FEU's -6.60 x $247.23 PER FEU ($1,631. 72)1 EXISTING: OOifi~~(l~\lD409SSVdP, 505 Main 5t.xls 1 Jl .Yi20o;, . . NUMBER OF FEU's -2.39 B. IMPROVEMENT COST: NUMBER OF FEU's -2.39 MWMC CREDIT IF APPLICABLE (SEE REVERSE) 546.88 PER FEU (Sll2.221l x 5494.46 PER FEU (SI,183.74)! x TOTAL MWMC REIMBURSEMENT FEE: TOTAL MWMC IMPROVEMENT FEE: MWMC ADMlNlSTRA TTVE FEE: TOTAL MWMC SDC:, S 24,843.30 SUBTOTAL (ADD ITEMS 1,2,3,&4) 1 S31,368.721 5 ADMINISTRATIVE FEES' BASE CHARGE (SUBTOTAL ABOVE) S 31,368.72 x 5% -, SI.568.441 TOTAL TRANSPORTATION ADMlNlSTRATION FEE:. S TOTAL SEWER ADMlNlSTRATION FEEJ S 8/412006 TOTAL SDC CHARGES , DATE .s;.... t1/. .B....l, &- SDC COORDINATOR COM2006-00844, Royal Bldg- SVdP, 505 Main St.xls SO.OO $2,15035 S22,682.95 SIO.00 S24,84330 , '-.\ WI",;",\,: ~,t';r;.. t:~"'){:' ~4:i'F. ~,,5:b;o; ~,,(>:.\., ,1054' 't'.:"'\..""; H86: "::;:'. .,...., >:m'7: \:;t.h,":.-';' &1189 .- -,~; --- 585.57 <h . ' ;;'7.~..:z'i 982.87 g:H~Q" S32,937.]6 1 JULY 2004 '" ....... ",' . . DRAINAGE FIXTURE UNIT (DFU) CALCUlATION TABLE NUMBER OF NEW FIXTURES x UNIT EQUTV ALENT - DRAINAGE FIXTIJRE UNITS (NOTE: FOR REMODELS. CALCUlATE ONLY TIlE NET ADDITIONAL FIXTURES) Mid-rise ""artmc:nts(331 with c..___;a1 property below FIXTIJRE TYPE BA TIITUB DRINKING FOUNTAIN FLOOR DRAIN, FLOOR SINK INTERCEPTORS FOR GREASElOIlJSOLIDS/ETC. INTERCEPTORS FOR SAND/AtITO WASHIETC. LAUNDRY TUB CLOTIlES W ASHER/MOP SINK CLOTIlES WASHER - 3 OR MORE (EA) MOBD..E HOME PARK TRAP (I PER TRAILER) RECEPTOR FOR REFRlGERA TORIW A TER ST A TION/ETC. RECEPTOR FOR COMMERCIAL SlNKI DISHW ASHERlETC. SHOWER, SINGLE ST AU. SHOWER, GANG (NUMBER OF HEADS) SINK: COMMERCIAL, RESIDENTIAL K.J J ......lICI'~ SINK: COMMERCIAL BAR SINK: WASH BASINIDOUBLE LA VA TOR Y SINK: SINGLELAVATORY/RESIDENTIALBAR URINAL, ST AU1W AU. TOD..ET, PUBLIC INSTAllATION TOD..ET, PRIV ATE INSTAllATION MISCELLANEOUS: NUMBER OF EDU'S' FIXTIJRES NEW OLD 33 1 I UNIT EOUTVALENT 3 I 3 3 6 2 3 6 12 I 3. 2 2 3 2 2 1 5 6 3 1 3 3 34 35 2 2 3 33 TOTAL DRAINAGE FIXTURE UNITS- . .EDU (Equivalent DwellinR Unit) is a dischBrJZ:c equivalent to a sinJrle family dwellinll; (20 DM set at 167 RalIons ~ CREDIT CALCUlA TION TABLE: BASED ON ASSESSED VALUE IF IMPROVEMENTS OCCURRED AFl'ER ANNEXATION DATE IN TABLE, CALCUlATE CREDITS SEP ARA TEL Y YEAR ANNEXED 1979 or before 1980 1981 1982 1983 1984 1985 .1986 1987 t988 1989 1990 1991 RATE PER SI,OOO ASSESSED VALUE S5.29 ". S5.19' , -,.... . S5.12' '$4.98" '. $4.80'. , ':'$4,63 i , $4AO.', .:. $4.07, , S3:~f " S3.22; '$1:73' $liS :""$1080' CREDIT FOR PARCEL OR LAND ONLY IF APPLICABLE IMPROVEMENT (IF AFl'ER ANNEXATION DATE) COM2006-00B44. Royal Bldg- SVdP, 505 Main St.xts YEAR ANNEXED 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 RATE PER Sl,OOO ASSESSED VALUE ,",' :'-':':>';'~~)' ,') :;>;, Sl.45 .;: : -:.:r \S1.25~' , .,;..c. .". " -,;::..Sl.09' ,'~ :r'.~ SO.92"' d':..', ., ~."'.;:~:' ~ \~: -$6..72 . ","'S' 0:48' , '-. " :'. S0.28; ," . SO.09' >:..,":',.:.:. ~_::.'$O'.05t. ;, '''-:SO~ori. ,.' "SO.OO' . ,.. SO.OO x x CREDIT TOTAL DRAINAGE FIXTIJRE UNITS 99 J 3 o o 2 9 18 o o o o o 99 o o 33 o -6 99 o o o 357 SO.OO SO.OO SO.OO 1 JULY 20QJI RECEIPT #. 2200600000000001250 ete: 09/07/2006 2:35:57PM Job/Journal Number Description Amount Due C:OM2006-00844 Addressing Assignment 31.00 COM2006-00844 Fire SF Fee - Non-Residential 3,057.50 COM2006-00844 Backtlow Device 14.00 COM2006-00844 Buiiding Permit 14,875.40 COM2006-00844 Sanitary Sewer - Reimbursement 2,322.87 COM2006-00844 Sanitary Sewer - Improvement 1,766.31 COM2006-00844 SDC Transpo Reimbursement 450.25 COM2006-00844 SDC Transpo Improvement 1,986.00 COM2006-00844 SDC MWMC Reimbursement 2,150.35 COM2006-00844 SDC MWMC Improvement 22,682.95 COM2006-00844 SDC MWMC Administration 10.00 COM2006-00844 SDC SanitarylStorm Admin 982.87 COM2006-00844 SDC Transpo Admin 585.57 COM2006-00844 Plan Review Plumbing (30%) 90.00 COM2006-00844 Fixture 2,310.00 COM2006-00844 Furnace - up to 100,000 btu 468.00 COM2006-00844 Exhaust Hoods 684.00 COM2006-00844 + 8% State Surcharge 1,468.11 COM2006-00844 + 10% Administrative Fee 2,140.89 COM2006-00844 -Mechanical Issuance Fee- 10.00 COM2006-00844 FLS Safety Systems Review 60.00 COM2006-00844 + 10% Administrative Fee 6.00 Item Total: $58,152,07 Payments: t:heck Number Authorization Type of Payment Paid By Received By Batch Number Number How Received Amount Paid Check ST. VINCENT DE PAUL jmp 002678 In Person $58,086.07 SOCIETY CreditCard KRISTEN M KARLE jmp 03549C In Person $66.00 Payment Total: $58,152.07 cReceinll Page 2 of2 9/7/2006