HomeMy WebLinkAboutPermit Building 2006-9-7
.
. CITY OF SPRINGFIELD
Building/Combination Permit
225 Fifth Street, Springfield, OR
541-726-3753 Phnne
541-726-3676 Fax
541-726-3769 Inspection Line
~
,
PERMIT NO: COM2006-00844
ISSUED: 09/07/2006
APPLIED: 07/07/2006
EXPIRES: 03/07/2007
VALUE: $ 4,502,367.00
Status
Issued
SITE ADDRESS: . 505 Main St
ASSESSOR'S PARCEL NO.: 1703353110400
Springfield TYPE OF WORK: Apartment Building
TYPE OF USE: New
PROJECT DESCRIPTION: Royal building - 5 story residential and commercial building
Commercial
Owner:
A.ddress:
ST VINCENT DE PAUL SOCIETY
705 S SENECA
EUGENE OR 97402
Phone Number: 541-687-5820
I CONTRACTOR INFORMATION I
.\,::::,'<;" ~
Contractor ~",,' ~\)
ANNE DELANEY ,i '\~" f.> ~
MElLI CONSTRUCTlON'CO,\)
,\.J" ("\'(.' <~"\)
BUILDERS ~~~<:I~BI~\!,NC
HOME COMFORT HEATING & AIR'
.\...'\\ < '<' <"\Y"
~9Blt'I$O~~.t:"'1,JMBING INC 1071~4
.....f;;;,,,\"~'v~~'v\) ~ \)~ ~I: BUILDING INFORMATIONI~"" ~
"'~~<:o <;::,~ <;..,<,::-",,<:<,<'::-. .~<z,'? ~v'~'Or:,"
# of Units: '\ . ,,\~ ...:5v~ \J~ # of Stories: d' n& n"'e, ,/J5'Q"" Lot Size:
. """, ~". 0.'0 . .'<i ~V' ~v co,. ..,
Primary Occupancy Grou~;~ 'U R2 HeIght ofStru!:.tur~Ci '" ~ ().. 6~,.00 /~ ~q Ft 1st Floor:
Secondary Occupancy GrouI}i~ M Type of Hea(I' xs:' <.:~<z,. 0' E;,1~ctricV ._.Sq Ft 2nd Floor:
Primary Construction Type IA Water TY,y';:/.)'Q""o"'<z, ",2$' I':le~tric. Sq Ft Basement:
Secondary Construction Type: V A Ran~~~'f,yg!:? ,,'<::' ;{i-O r::/;-~~Iee!rie ;-" Sq Ft GaragelCarport
# of Bedrooms: Energy,Path1" ,<::) do> ,c!,' Path I.' Sq Ft Other:
Sp~inKI.rd(B~i1ding? ~~ \~ "'~'-~l1j'/~ Occupant Load:
;(X/ ".s- _ \,) ,,": ~ J ,.,' o,J"
License
Expiration Date
Contractor Type
Architect
General
Electrical
Mechanical
Plumbing
63771
4296
84164
02/12/2008
12/10/2007
06/25/2007
07/13/2007
PhDne
541-683-8661
541-485-1417
541-485-0922
54] -345-2838
541-345-6909
7,865
7,865
22,710
172
Front yard Setback:
Side I Setback:
Side 2 Setback:
Rearyard Setback:
Solar Setbacks:
I Dc. cLvr.tvIENT INFORMATION I
. ~v........ :v 'J ~Y' ~
_'.0 0'("" ..,0 .~' ,'" ,,'
,,- f'\. ...c~ ,..0 ~e;
Ove.rlay Dist: V 'C,,-"
("\V n.' '{"j ,
# Street,Trees Rqd:
v'
Paved Drive Rqd:
% of Lot Coverage:
REQUIRED PARKING
Total:
Handicapped:
Compact:
I PUBLIC IMPROVEMENTS I
Street Improvements:
Storm Sewer Available:
Special Instruction:
Sidewalk Type:
Downspouts/Drains:
Notes:
Pa!!e I of6
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone'
541-726-3676 Fax
541-726-3769 Inspection Line
Description
Estimate
Tvpe of Construction
Estimate
Fee Description
Plan Review Comm/lnd/Public
Plan Review Fire & Life Safety
-Mechanical Issuance Fee-
+ 10% Administrative Fee
+ 100/0 Administrative Fee
+ 8% State Surcharge
Addressing Assignment
Backnow Device
Building Permit
Exhaust Hoods
Fire SF Fee - Non-Residential
Fixture
FLS Safety Systems Review
Furnace - up to 100,000 btu
Plan Review Plumbing (30%)
Sanitary Sewer - Improvement
Sanitary Sewer - Reimbursement
SDC MWMC Administration
SDC MWMC Improvement
SDC MWMC Reimbursement
SDC SanitarylStorm Admin
SDC Transpo Admin
SDC Transpo Improvement
SDC Transpo Reimbursement
Total Amount Paid
.
I Valuation Descriotion ,
$ Per Sq Ft
or multiplier
$1.00
Square Footage
or Bid Amount
4,502,367,00
Total Value of Project
Fpp,. PiWU
Amount Paid
Date Paid
$9,669,01
$5,950,16
$10,00
$6,00
$2,140.89
$1,468,11
$31.00
$14,00
$14,875,40
$684,00
$3,057,50
$2,310,00
$60,00
$468,00
$90,00
$1,766,31
$2,322.87
$10,00
$22,682,95
$2,150,35
$982,87
$585,57
$1,986,00
$450,25
7/7/06
7/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
9/7/06
$73,771.24
I Plan Reviews I
Paee 2 of6
. CITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: COM2006-00844
ISSUED: 09/07/2006
APPLIED: 07/07/2006
EXPIRES: 03/07/2007
VALUE: $ 4,502,367.00
Value
Date Calculated
$4,502,367,00
$4,502,367,00
07/07/2006
Receipt Number
1200600000000001029
1200600000000001029
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
2200600000000001250
. CITY OF SPRIr~url":LD
Building/Combination Permit
PERMIT NO: COM2006-00844
ISSUED: 09/07/2006
APPLIED: 07/07/2006
EXPIRES: 03/07/2007
VALUE: $ 4,502,367.00
:-S~G'I!!I~.iij
~-
.~.....
.
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Fire Department Review
09/06/2006
09/06/2006
OK
GRG
Fire Department Review 07/10/2006 08/30/2006 OK GRG
Initial Review 07/10/2006 07/10/2006 APP LLH
Plan Review Comments 08/09/2006 10 JMP
Plannine Review 07/10/2006 07/26/2006 APP EMM
Plumbine Plan Review 08/22/2006 08/22/2006 OK SKG
Public Works Review 07/10/2006 08/02/2006 APP SB
Revised Plan Review - Fir 09/05/2006 09/05/2006 OK GRG
Paee 3 of6
Plans Review: Stuh up for future
sprinklerlstandpipe assemhly for
Royal Building, Job
#COM2006-00844, Designer: Mike
Tennant, Contractor: Omlid and
Swinney, Plans appear to meet code
requirements.
Note for plans: City of Springfield
Building Department has changed
the address numher for the new
building 10 505 Main Street,
See attached comments for Fire
Department Plans Review
comments.
WE, See attached document for
cover for 3 electrical comments
faxed to Anne DeLaney.
LDAP Issued, Addcd SDCs.
Plans Review: SI. Vincent DePaul
Royal Building-main structure
(Phase II-2nd
revision-supplemental), Job
#COM2006-00844, Occupancy
Classifications: A-2, B, M, R-2, S-1.
Construction Types: 1st noor: I-A
Sprinklered; 2nd through 5th noors:
V-A Sprinklered,
E-mail from Robert Castille, City of
Springfield Building Inspector to
Anne DeLaney, Architect for
Bergsund DeLaney Architecture and
Planning asking for firelsmoke
damper submittal. Submittal shows
fire smoke dampers on 2nd through
5th noors, Fire smoke dampers shall
he monitored by the fire alarm
system,
. CITY OF SPRINGFIELD'
Building/Combination Permit
PERMIT NO: COM2006-00844
ISSUED: 09/07/2006
APPLIED: 07/07/2006
EXPIRES: 03/07/2007
VALUE: $ 4,502,367,00
.
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Revised Plan Review - Fir
07/25/2006
GRG
08/31/2006
OK
Revised Plan Review - Pia 07/25/2006 07/26/2006 APP EMM
Revised Plan Review - Pu 07/25/2006
Revised Plan Review - Str 07/25/2006 07/25/2006 10 JMP
Revised Plan Review - SU 07/25/2006
Structural Review 09/07/2006 09/07/2006 APP JMP
Slructural Review 07/10/2006 07/19/2006 WE JMP
SUB Review 07110/2006 08/17/2006 APP JF
Addendum I.
Plans Review: St, Vincent OcPaul
Royal Building-main structu rc
(Phase II-1st revision), Job
#COM2006-00844, Occupancy
Classifications: A-2, B, M, R-2, S-1.
Construction Types: 1st noor: I-A
Sprinklered: 2nd through 5th noors:
V-A Sprinklered,
Additional emergency egrcss
lighting shown on Buildcrs Elcctric
Plan Sheet E2-firsl noor north
egress and lobby arcos, Will verify
on inspection.
Addendum I
Addendum I
WE, Addendum I.
Addendum 1
Received responses to structural
comments and final internal
approval.
See attacbed documents for 7
structural comments faxed to Anne
DeLaney,
Using SUB's incentive program,
To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m.
will be made the same working day, inspections requested after 7:00 a.m, will be made the following work
day.
I RP"IIWlrf In<.nprt~
Site Inspection: To be made after excavation but prior to setting forms,
Erosion/Grading Inspection: Prior to ground disturbance and after erosion measures are installed,
Rough Plumbing: Prior to cover and including required testing,
Final Plumbing: When all plumbing work is complete,
Rough Mechanical: Prior to Cover
Final Mechanical: When all mechanical work is complete,
Rough Electric: Prior to Cover
Final Electric: When all electrical work is complete,
SUB Insulation Vapor Barrier: To be called for at the same time as the SUB framing inspeclion,
SUB Final: After all required energy inspections bave been requested and approved,
SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover,
Paee 4 of 6
~~-;'.,.
~...
.
. CITY OF SPRINGFIELD'
Building/Combination Permit
PERMIT NO: COM2006-00844
ISSUED: 09/07/2006
APPLIED: 07/07/2006
EXPIRES: 03/07/2007
VALUE: $ 4,502,367.00
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
SUB Ceiling Grid: Interior Lighting
SUB Exterior Lighting
Ufer Electrical Gronnd: Iostall gronnd rod at footing and call for inspection in conjunction with footing andlor
foundation inspection,
Footing: After trenches are excavated.
Foundation: After forms are erected but prior to concrete placement.
Slab: To be made after all inslab building service equipment, conduit piping and other equipment items arc in
place but prior to concrete,
Shear Wall Nailing: Before covering sheathing with finish materials,
Framing Inspection: Prior to cover and after all rough in inspections have been approved,
Wall Insulation: Prior to cover,
Ceiling Insulation: Prior to cover.
Roofing: Prior to installing any roof covering.
Firewall: Located and constructed according to plans,
Masonry:
Bolts Installed in Concrete: To be done by a State Certified Special Inspector, Provide inspection test reports to
City Building Inspector.
Structural Concrete: In excess of2500 psi, To be done during construction by a State Certified Inspector.
Provide results to City Buiding Inspector
Roof Sheathing/Nailing: Before covering sheathing with finish material.
Glu-Lam Beams: Inspection Certificate by an approved agency to be provided to City Building Inspector prior to
placement.
Ceiling Grid: After dl")'wall approval but prior to cover,
Hold Downs Installed: Special Inspection performed prior to placement of concrete, Provide report to City
Building Inspector,
Epoxy Anchors: To be done by Certified SpcialInspector. Provide Inspection results to City Building Inspector,
Structural Welds: To be done during construction by State Certified Special Iospector, Provide inspection test
results to City Building Inspector,
Final Fire Department. After all requirements of the Fire Department have been met,
Final Building: After all required inspections have been requested and approved and the building is complcte,
Rough Grading: After gravel is in place but prior to placing concrete,
Final Paving: After paving is complete.
Underslab Plumbing: Prior to filling the trench and including required testing,
Paee 5 of6
.
. CITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: COM2006-00844
ISSUED: 09/07/2006
APPLIED: 07/07/2006
EXPIRES: 03/07/2007
VALUE: $ 4,502,367,00
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
I I
I
By signature, 1 state and agree, that 1 have carefully examined the completed application and do hereby certify that all
information hereon is true and correct, and 1 further certify that any and all work performed shall be done in accordance with
the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and
that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety,
I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project.
I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the
street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all
"om '"ri'~i'~ ~ r, "if>>~
0.... o.t'''m~m ,;,..'1tt- 0'"
Paee 6 of6
~u
o..i.
'"
I/)
'"
o
o
o
o
o
I/)
....
o
~,
-.
o.
Ui,.
-,
" .
~~
~~
~,
o.
Ui,.
-,
-
..
..
"-
..,
..
<>
('fi
C'1Iy of SprinefieJd
Cornmomily S...ices DMsion
22S FifiIJ 5_
Si>"in~ld, Oil 974n
T~: {54I} 726-3759
Fu.: (541) 726-1689
Cb M "Z..<<lC> C:. - eo 8 "Z.. ~
Bui.Idiqj P..... ~ .
-rH~
~YAL,....
PIojecl rill.
'i)oS HAHJ -:~E.T"'
Proj<cl Ad,!,...
.,. "t.o,oC:.
0....
1?::>L.~.
z
~
...
g
T.appi..... .rf'8i_ "'1Uirirw -~ mpa,ion ................S.dian 11IoIofdlo ~su..:n.... S...'illIIyCod. 1'1_ p<yi,,,fIlc -......_. 1II_,...Jw"
lftisln...mo..b!ro..,..... . . ~q:oIlbe ;"C-.....llysipi..klo"'._murnllN _,.... CiJ~.
BlrolUr A PBlUoIfTC''''' 81 ISliUI:ll: TIIo__.._., _.....;..... .....'M.oo...h, "'_........&p.a:,.. ,\r<IIi..... _I'....,.d., ~li"o.....""...il......
a", tQ'~i'.tIlda,~ diu formrOZ'Plplelrdealle1b lib _I udhcl
no ....,,"..,.,Gc_c.e..a01. _. "Wli""... JhaJ'oI...........I<d.. ollo COllD_..,.. .. .. '. ...,,;.-.. Sp:....lN,..tiao ""*,,,T..,jog.
SpecioIlarpectioor .... TffliDe
.
'"
o
o
~
....
-
~
...
I. c.'_j, l<tpcadllloor.,. _notili..... rv....Ilupc<1ioawT...q,.ri.....1iasL
2. T.,lMa "'_1101)' -...., "",,","a, '-plt.... . ,,,,. ......,.Ita:~ _...." ... _'" -..i..... ""'"'"
· CopiaofolJ -lDJ'_u"-,,,,,, II' ..be_....Cilylly.... TUIio:AII'll<JI,
..J
~
-
z
o
:E
~
~
L ..,
~ ~
. -
'"
~
-
'..
J. S.......I..."i... ~ is '" "'bm~ "'.... D4 qaoIillc1llJOlllI or..... Sf..... 10........ .. rIw ul)' r., _....
4. SpccioI,._ - provide WP<d..._.......""illincolli<i.. .raUimpuJi.......<ilic:s.
So C_...., is _n_hk 10 m;.-.... C-1Iy '., , .: pIouliroddili""'I...~...., laIi..IUl..;'_lhalmo,....1M
..roU4 CKRn11CA11l or OCCUPAIlC\' WILL "I.IS~ID: Th'~;'1 fJlSjl<CliDll "-_ ,1IaI1 MIo;'" tIie 8oil~ orncc. ._....."'" all ;'..... ~'1
j_..",.. bee.. fidljf1ed an.! ",",.ed.... --- '" ltI. 6cJl orchc i_l..,.Jooo.n;IaJ:o, in .""'_,..i1b dot _'04 pia... Jllft:i__ .........l~_......
". ::. ,S ..,.. ;,"". -'ured_o'Wp.t1c4_b...-........-..- Tho .......is..""..bot.i..~"'dreCilyjOior ..._IO'r...j.......,..,..
~
~
.
~
~
t:
.
L~
J
J :::
J ~
) -
..
) ..
, ~
"-
to.
0_
AClCNOWl.EDGBMEHrs
~,V,'ru..d' -k- ~ul___ t1.~IL( C.t:1~rFtvc.nD~_
o...u "'-<: (Pti.led) ~o.m", si&naAt.. , 0.0. lAJ_lllr Finn Home ~
~oh!x:lc.J,- Le.l.4.>in _V~ ~ .r~1 _
~..................~'A ';:/i:::~-' ~-'~~ ~';";
T"*'l LaMlra!OIy Na., O'>inled) T..,;", LobcalOfy~. SiglJaturc Bu~ti.tl NIIrI. (Prlid';')
tJr~.L .
Gcmnll c.........r si........
~~.I.;;,;~~ ~~
"::::..... ~ ". - g
lMidin~ Si.Pl1Jlre '"
. "-
h
..
~;
I':ll:: ,. ".\
lL
'"
OJ'
<
~
<:>
<:>
....
~
<:>
<:>
S
SPECIAL INSPECTION Ai'll) TZSTING SCHEDULE
I Reiafooced Cancrt1e, Gunite. Grout and MoJ\;U:
i eon",,'e _l Guorlle I Groot I Morw
I -tHJ<.i I
I "" I
I
; Ae~~c TC5t of Mix Dcsillttl
I Reinbci~ Test
Mix Dcsi Wei!hmastec Ccrt..
ReinlomM Pla<emenl
i Corninuous B..cI1 PIIIIlIIMDcl:I.
i I"'''''d Pb:iIl.
I Cs SaDDles
r S.1JDolcs (Pick\lD'Delivcrml
I COl1llK'eSSion Tat.
.....
GRADING,EXCAVATlOi'l,A.IIDnLL lpt'f" '3t:Q\1n1\'1lC~
Acceptance Ie..... I'SF en5' neeV' I
Eotohlisb final gr.de
~ Fill ptacancn. inspectioo/CllIl.inUOllS
X. Soil Dcn.i.ly ~ u'tS ~AADC ~T R u...-
~
....l
'"
<:>
'"
.
STRUCTUJlALSTUUWKLDING: Ul'IItl.eml.:lS'l
Sampl.ondlest(lisI.peciflcme.......bclowll ">e"'kIer .-)
Shop moleriaJ ideotifio:a1ion (mill <<rtl
\Yeld inspection ~Shop L.Fjel~
UI1rasomie inspect;o. _Shop _F",I~
High Slrtusth Bollillg_Shop _Field
A325 _N _X
A490 N X
Mellll deck '''''!ding imjl<l:lion -
Tteinrortin: Sled wcJdirI: iaspectitm
Rcinfon::ing.:StJ:d mill cenifiClIe
MctnJ stud \Y~Jding inspection
Conaclc insert welding inspection
Moment relisJ:ing stetl m.ne,
(;1J 1
Pm:..up~""esscd Com:n:le:
Pit.. Post- T '''1 Pr.~r ens
~j
':~
I
Oaddi..
_F
_F
.~e~c Te....
R.c:inlorcmE Tests
Tendon T cst
Mix Desi.p.ns~
Rcinforci02 PJacmJm
''''''11 PIac","""
Concrete Batcllin2
Cancrck 'PJart:ma'lt
lnslatlation In.tpettion
'(;Sam.l..
J Pidc-UD SDmo.!c:S
I Camoressian Te.!ts
STRUCTURAL WOOD:
Shear \w..Il D~iling inspccrlon
Sh<... ...11 arn:hor.
~ InSjJCdion af GIIl-lam fab.' 4'- TIC.,.i
~ Inspection or truss joist fab.
Sample and test c." 'I' ,..,Js
Fabrication "'l:Jding ohtcd ....'"I:cs:5orics
x
..,
'"
'"
)c..
y
"
"'
..,
-<
-<
..,
00
"'
-<
~
on
SMOKE CONTROL,
. Lenlcage lUting
.Control Verifiaion
MASONRY
;>< Spccialif\S!lCl:tion_...d.~l'm-*-rg
Preliminary accepcaoce tots (masoa.ry units, Willi prisms)
Snbscquen.1csts (marlar, groul, rldJ w.1I prisms;
X PI~cmenl inspc:ctionof\miu. and reinforcement
Masonry, mortnr. gl'OU(, and reinforcing steel ccrtifLC:J1eS
FlREPROOJllNG:
Placerci:nI: impa:lion
Ikmity tc.sls
Thickness tC1t$
I""pcct holdling
ROOFDlG,
In.snfafioD i~h1ttonlR-VoJuc.
Trn.stri""'<1IIJ\'
~
""
ADDITIONAL INSRUCI1ONS, OTHER TEST. '" INSPECIlONS:
i) ?r-oVld!":. ~\o..e Ih~C.tl"'" .for'" \'"Od.~ -;e-\- in
').') ~ioJI \~c.,~ilM~ -to be.. CJ1'(l\-\VI\.4QU!:> nn\'i
C.nClD~V" \ 7 .
Form CumpJet.cd hv-
f;:po)<'1' (Oe.A.. \(L ~DOyb )
uMevI"_ ~ec.\ hrl \~ \ ~ ht;Gc..
..,
..,
. 0...
..
00
o
"'
o
o
..
....
<-
-<
......:-..
<-
o _
'PROVlDE STRENGTH REQUIRED BY ARCJlrrKCT OR ENGINEER OR CONTRACT DOCUlrlENT LOC\ TlON OF VALUES .
L pep.. ~TU~I... ~~e co 1-\ ee..T
Si,O"
"
m
.....
.....
...
'"
.....
'"
m
m
'"
m
'"
....
'"
.....
.
n
....
-I
<
o
."
r.n
:ll
.
f!!
"
"U
1>
Gl
fTI
m
'"
AlTACHMENT A
CITY OF SPRINGE SYSTEMS DEVELOPMENT CHARGE WORKSHEWffective I Julv. 2006)
JOURNAL OR JOB NUMBER CO 0844 .
NAME OR COMPANY: St Vin=t de Paul- Roval B1do
LOCATION: 505 Main St
MAP & TAX LOT NUMBER: 17 03 35 31 10400
PEVELOPMENT TYPE: _ Mid-rise "P'"J""~~~33) with G..___;a1 e'"e-', below
NEW DEVELOPED AREA (S.F.): 33.00 Mid Rise Res.
NEW DEVELOPED AREA (S.F.): 4,136.00 Specialty Retail
EXISTING DEVELOPED AREA (S.F.): 6,600.00 Discount Store
EXlSTING DEVELOPED AREA (S.F.): 2394.00 Office
TOTAL IMPERVlOUS SURFACE (S.F.): 8.604_
STORM DRAINAGE LESS NEW IMPERVlOUS
IMPERVlOUS SQ. IT. x $ 0.336 PER SF
i....,.-'
~
ITE:
ITE:
ITE:
ITE:
LOT SIZE (S.F.):
223
814
815
710
8604
TOTAL STORM DRAINAGE SDC:Lu
81
= '8
~ ~ ~
"' H .:
..t. u
8 " .1ii
E- "
o ~ il!
$0.00 I
$0.00 1178
2 SANITARV ":,~V"l=~
A REIMBURSEMENT COST:
NUMBER OF DFU's 357
B. IMPROVEMENT COST:
NUMBER OF DFU's 357
(SEE REVERSE SIDE)
Downtown Dtvelopmcnt Cndit (75".)
x $ 26.03 PER DFU
x $ 19.79 PERDFU
$ 45.82
TOTAL WCAL WASTEWATER SDC:'
3 TRANSPORTATION
BLDG AREA TGSF x TRlP RATE x COST PER ADT x NEW TRlP FACTOR
NEW
A REIMBURSEMENT COST:
33.00 x 6.59
B. IMPROVEMENT COST:
33.00 x 6.59
NEW
A REIMBURSEMENT COST:
4.14 x 44.32
B. IMPROVEMENT COST:
4.14 x 44.32
EXISTING
A REIMBURSEMENT COST:
-6.60 x 56.02
B. IMPROVEMENT COST:
-6.60 x 56.02
EXISTING
A REIMBURSEMENT COST:
-2.39 x 11.01
B. IMPROVEMENT COST:
-2.39 x 11.01
x
$ 19.81 PER TRlP
x
NTF
NTF
0.75 NTF
0.75 NTF
0.65 NTF
0.65 NTF
0.9 NTF
x
$ 87.39 PER TRlP
x
x
S 19.81 PER TRlP
x
x
$ 87.39 PER TRlP
x
x
$ 19.81 PER TRlP
x
x
$ 87.39 PER TRlP
x
x
$ 19.81 PER TRlP
x
$ 87.39 PER TRlP
$ 107.20
TOTAL TRANSPORTATION REIMBURSEMENT SOC:'
TOTAL TRANSPORTATION IMPROVEMENT SOC:'
DowntowD Development Credit (7S./.) TOTAL TRANSPORTATION SDC:~
0.9
NTF
x
x
$9,291.47 1
$7,065.23 I
SI6,356.69 I
$2,322.87
$1,766.31
$4,089.17
$4,308.56 I
$19,004.751
S2,723.791
$12,014.46 1
($4,76l.38)I
($21,002.12)1
($469.99)1
($2,073.08)'
$1,800.98 I'
S7,944.01 1
S9,744.99 1 $
$450.25
S I ,986.00
2,436.25
4 SANITARY SEWER - MWMC
NEW:
A REIMBURSEMENT COST:
NUMBER OF FEU's 33.00 x S70.31 PER FEU $2.320.32 ~
B. IMPROVEMENT COST:
NUMBER OF FEU's 33.00 x S741.69 PER FEU $24,475.87 I
NEW:
A. REIMBURSEMENT COST:
NUMBER OF FEU's 4.14 x $23.44 PER FEU $96.94 I
B. IMPROVEMENT COST:
NUMBER OF FEU's 4.14 x $247.23 PER FEU $1,022.55 I
EXlSTING:
A REIMBURSEMENT COST:
NUMBER OF FEU's -6.60 x $23.44 PER FEU ($154.69)1
B. IMPROVEMENT COST:
NUMBER OF FEU's -6.60 x $247.23 PER FEU ($1,631. 72)1
EXISTING:
OOifi~~(l~\lD409SSVdP, 505 Main 5t.xls 1 Jl .Yi20o;,
.
.
NUMBER OF FEU's -2.39
B. IMPROVEMENT COST:
NUMBER OF FEU's -2.39
MWMC CREDIT IF APPLICABLE (SEE REVERSE)
546.88 PER FEU
(Sll2.221l
x
5494.46 PER FEU
(SI,183.74)!
x
TOTAL MWMC REIMBURSEMENT FEE:
TOTAL MWMC IMPROVEMENT FEE:
MWMC ADMlNlSTRA TTVE FEE:
TOTAL MWMC SDC:, S 24,843.30
SUBTOTAL (ADD ITEMS 1,2,3,&4) 1 S31,368.721
5 ADMINISTRATIVE FEES'
BASE CHARGE (SUBTOTAL ABOVE)
S
31,368.72 x 5% -, SI.568.441
TOTAL TRANSPORTATION ADMlNlSTRATION FEE:. S
TOTAL SEWER ADMlNlSTRATION FEEJ S
8/412006 TOTAL SDC CHARGES ,
DATE
.s;.... t1/. .B....l, &-
SDC COORDINATOR
COM2006-00844, Royal Bldg- SVdP, 505 Main St.xls
SO.OO
$2,15035
S22,682.95
SIO.00
S24,84330
, '-.\
WI",;",\,:
~,t';r;..
t:~"'){:'
~4:i'F.
~,,5:b;o;
~,,(>:.\.,
,1054'
't'.:"'\.."";
H86:
"::;:'. .,....,
>:m'7:
\:;t.h,":.-';'
&1189
.-
-,~;
---
585.57 <h . '
;;'7.~..:z'i
982.87 g:H~Q"
S32,937.]6
1 JULY 2004
'"
.......
",'
.
.
DRAINAGE FIXTURE UNIT (DFU) CALCUlATION TABLE
NUMBER OF NEW FIXTURES x UNIT EQUTV ALENT - DRAINAGE FIXTIJRE UNITS
(NOTE: FOR REMODELS. CALCUlATE ONLY TIlE NET ADDITIONAL FIXTURES)
Mid-rise ""artmc:nts(331 with c..___;a1 property below
FIXTIJRE TYPE
BA TIITUB
DRINKING FOUNTAIN
FLOOR DRAIN, FLOOR SINK
INTERCEPTORS FOR GREASElOIlJSOLIDS/ETC.
INTERCEPTORS FOR SAND/AtITO WASHIETC.
LAUNDRY TUB
CLOTIlES W ASHER/MOP SINK
CLOTIlES WASHER - 3 OR MORE (EA)
MOBD..E HOME PARK TRAP (I PER TRAILER)
RECEPTOR FOR REFRlGERA TORIW A TER ST A TION/ETC.
RECEPTOR FOR COMMERCIAL SlNKI DISHW ASHERlETC.
SHOWER, SINGLE ST AU.
SHOWER, GANG (NUMBER OF HEADS)
SINK: COMMERCIAL, RESIDENTIAL K.J J ......lICI'~
SINK: COMMERCIAL BAR
SINK: WASH BASINIDOUBLE LA VA TOR Y
SINK: SINGLELAVATORY/RESIDENTIALBAR
URINAL, ST AU1W AU.
TOD..ET, PUBLIC INSTAllATION
TOD..ET, PRIV ATE INSTAllATION
MISCELLANEOUS:
NUMBER OF EDU'S'
FIXTIJRES
NEW OLD
33
1
I
UNIT
EOUTVALENT
3
I
3
3
6
2
3
6
12
I
3.
2
2
3
2
2
1
5
6
3
1
3
3
34
35 2
2 3
33
TOTAL DRAINAGE FIXTURE UNITS-
. .EDU (Equivalent DwellinR Unit) is a dischBrJZ:c equivalent to a sinJrle family dwellinll; (20 DM set at 167 RalIons ~
CREDIT CALCUlA TION TABLE: BASED ON ASSESSED VALUE
IF IMPROVEMENTS OCCURRED AFl'ER ANNEXATION DATE IN TABLE, CALCUlATE CREDITS SEP ARA TEL Y
YEAR
ANNEXED
1979 or before
1980
1981
1982
1983
1984
1985
.1986
1987
t988
1989
1990
1991
RATE PER SI,OOO
ASSESSED VALUE
S5.29
". S5.19'
, -,....
. S5.12'
'$4.98"
'. $4.80'.
, ':'$4,63 i
, $4AO.',
.:. $4.07,
, S3:~f
" S3.22;
'$1:73'
$liS
:""$1080'
CREDIT FOR PARCEL OR LAND ONLY IF APPLICABLE
IMPROVEMENT (IF AFl'ER ANNEXATION DATE)
COM2006-00B44. Royal Bldg- SVdP, 505 Main St.xts
YEAR
ANNEXED
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
RATE PER Sl,OOO
ASSESSED VALUE
,",' :'-':':>';'~~)' ,')
:;>;, Sl.45
.;: : -:.:r \S1.25~'
, .,;..c. .".
" -,;::..Sl.09'
,'~ :r'.~ SO.92"'
d':..', .,
~."'.;:~:' ~ \~: -$6..72
. ","'S' 0:48'
, '-.
" :'. S0.28;
," . SO.09'
>:..,":',.:.:. ~_::.'$O'.05t.
;, '''-:SO~ori.
,.' "SO.OO'
. ,.. SO.OO
x
x
CREDIT TOTAL
DRAINAGE
FIXTIJRE
UNITS
99
J
3
o
o
2
9
18
o
o
o
o
o
99
o
o
33
o
-6
99
o
o
o
357
SO.OO
SO.OO
SO.OO
1 JULY 20QJI
RECEIPT #. 2200600000000001250 ete: 09/07/2006 2:35:57PM
Job/Journal Number Description Amount Due
C:OM2006-00844 Addressing Assignment 31.00
COM2006-00844 Fire SF Fee - Non-Residential 3,057.50
COM2006-00844 Backtlow Device 14.00
COM2006-00844 Buiiding Permit 14,875.40
COM2006-00844 Sanitary Sewer - Reimbursement 2,322.87
COM2006-00844 Sanitary Sewer - Improvement 1,766.31
COM2006-00844 SDC Transpo Reimbursement 450.25
COM2006-00844 SDC Transpo Improvement 1,986.00
COM2006-00844 SDC MWMC Reimbursement 2,150.35
COM2006-00844 SDC MWMC Improvement 22,682.95
COM2006-00844 SDC MWMC Administration 10.00
COM2006-00844 SDC SanitarylStorm Admin 982.87
COM2006-00844 SDC Transpo Admin 585.57
COM2006-00844 Plan Review Plumbing (30%) 90.00
COM2006-00844 Fixture 2,310.00
COM2006-00844 Furnace - up to 100,000 btu 468.00
COM2006-00844 Exhaust Hoods 684.00
COM2006-00844 + 8% State Surcharge 1,468.11
COM2006-00844 + 10% Administrative Fee 2,140.89
COM2006-00844 -Mechanical Issuance Fee- 10.00
COM2006-00844 FLS Safety Systems Review 60.00
COM2006-00844 + 10% Administrative Fee 6.00
Item Total: $58,152,07
Payments: t:heck Number Authorization
Type of Payment Paid By Received By Batch Number Number How Received Amount Paid
Check ST. VINCENT DE PAUL jmp 002678 In Person $58,086.07
SOCIETY
CreditCard KRISTEN M KARLE jmp 03549C In Person $66.00
Payment Total: $58,152.07
cReceinll
Page 2 of2
9/7/2006