HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-12-27 (2)
. ~~t"~
..." ...-
II ~'lljUI:t1/~' ~ III [Ill' IIIU!I
,/
.
.
Geoted1nical & Construction Servires
Compressive Strength of Concrete
(ASTM C 39)
CLIENT Ms. Kristen Karle PROJECT The Royal Building DATE 12-27-06
St. Vincent de Paul 501 Main Street PROJECT NO. 2067145
P.O. Box 24608 Springfield, Oregon REPORT NO. 4891
EUgene, Oregon 97402
B.P. NO. COM2006-00624
TEST AGE AREA WEIGHT TOTAL COMPRESSIVE
DATE (DAYS) (IN.') (LBS) LOAD (LBS) STRENGTH (PSI)
12-06-06 7 28.27 28.1 84300 2980
12-27-06 28 28.18 28.1 129000 4580
12-27-06 28 28.18 28.1 129200 4580
Hold
DATE CAST
STRENGTH REQUIRED
STRENGTH PLACED
PRODUCT CODE
ADDITIVES
LOAD NO.
CONCRETE TEMP
AIR TEMP
POUR LOCATION
LOAD 4 SAMPLED
11-29-06 CAST BY A. Fenstermacher DATE RECEIVED 11-30-06
3000 psi SPECIMEN SIZE 6" x 12"
3000 psi SACKS SUPPLIER MBI
24F4NE5200 CEMENT MAX SIZE AGG. 3/4"
Hot Water, Verifi Fibers AIR CONTENT
4 TICKET NO. 2554555 SLUMP 6"
56' F YARDAGE 10.5 OF 60.0 TIME 9:20 AM
34' F WEATHER Clear SPECIMEN STORAGE ASTM C31
Perimeter footing on line G, between 1 and 6; transformer room footing and stemwall; slab on grade
between lines 1 and 6, from D to G with the following exceptions: between 5.5 and 6, from E to G and
between 1 and 3.6, from D to E.
Near lines 4E.
AVERAGE
STRENGTH
(PSIl
TIME OF
TEST
9:50 AM
9:10AM
9:15AM
TYPE OF
FRACTURE..
D
E
E
4580
.. A . Cone B - Cone/Split C - Cone Shear D - Shear E - Columnar
REMARKS: Derick (Melli) was advised of on-site test results.
Reviewed By:
/Jtl!ul/t (;()
-Michael L. Meyer .
Technical Manager
Meili Construction - Curt Meili (e-mail)
Meili Construction - Curt Dawson (e-mail)
Bergsund Delaney Architecture & Planning (e-mail)
Hohbach-Lewin Structural Engineers (e-mail)
City of Springfield
MBI
c:
MLM:jm
RECEIVED
JAt'f 0 3 7007
This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full andlor any part
thereof be disclosed without FEI Testing & Inspection, Inc,'s written authorization.
750 r-NV CanelI Avenue' CcxvaIles, Oregon 97330, phone (541) 757-4698, fax (541) 757-2991
29540 B Airpo1 Road . Eugene, Oregon 97402 . phone (541) 684J849 . fax (541) 684-3851