Daily Field Report
Client: Ms. Kristen Karle Project: The Royal Building Date: 12-27-06
SI. Vincent de Paul 501 Main Street Project No.: 2067145
P.O. Box 24608 Springfield, Oregon Report No.: E15031
Eugene, Oregon 97402 Inspector: E. Marjama
ID No.: 5235029
Inspection of: Reinforcing Sleel Weather: Clear Continuous Inspection: 0
PT Tendons BPNo.: COM2006-00624 Periodic Inspection: Ii'l
Contractor: Meili Construction
Performed inspection on the reinforcing steel and post-tension lendons for second floor
slab. Site visits were made on December 20 and 27, 2006. Reinforcing steel was
checked for grade, size, lap, placement and clearance. Tendon quantities,
anchorages, profiles and supports were also checked. Tendons and rebar were
secured with tie-wire and supported with plastic chairs and slab bolsters. Deck surface
and drop caps were relatively clean and free of excess debris. Distributed tendons
along line 3.8 between D.4 and G were relocaled as per EOR's verbal instructions to
contractor to eliminate excess curvature tendons. Advised by Curt Dawson (Meili
Construction) that concrete placement is scheduled for tomorrow AM.
To the best of our knowledge, the work inspected was in accordance with PTC .
drawings dated 11-06, plans dated 08-30-06 and applicable workmanship provisions of .
the I.B.C., except if noted above. Contractor was asked to notify our office when
additional services are needed.
Reviewed By:
fh-A'. ~
Michael L. ~eye{l
Technical Manager
c: Meili Construction - Curt Meili (e-mail)
Meili Construction - Curt Dawson (e-mail)
Bergsund Delaney Architecture & Planning (e-mail)
Hohbach-Lewin Structural Engineers (e-mail)
City of Springfield
MLM:jw
This report andlor enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such. information contained herein shall not be reproduced in part or full andlor any part
thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization.
750 NVV ComeII Avenue . Corvallis. Oegon 97330 . phone (541) 757-4698 . fax (541) 757-2991
29540 B Airpat Road . Eugene, Oegon 97402 . phone (541) 684J849 . fax (541) 684-3851