HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-12-28 . . ~fEI / Page 1 of 1 Geotechnical & Consb1.Jction Services Daily Field Report .1~'llllfl;"lf~~ll~IIIII(_ Client: Project: The Royal Building 501 Main Street Springfield, Oregon Date: Project No.: Report No,: Inspector: ID No.: Ms. Krislen Karie St. Vincent de Paul P.O. Box 24608 Eugene, Oregon 97402 12-28-06 2067145 E15010 E. Marjama 5235029 iCC Inspection of: Reinforced Concrete Contractor: Meiii Construction Weather: Overcast BP No,: COM2006-00624 Continuous Inspection: D Periodic Inspection: 0 Performed final inspection on the reinforcing steel and PT tendons for the second floor slab, lines A to G, from 1 to 6. Preliminary inspections were performed on 12-20-06 and 12-27-06 (ref.: FEI report no. E15031). Observed the placement of 270.0 cu./yds. of MBI 5000 psi concrete (Mix 2450K050KS) in areas listed above. Concrete was placed by pump and was mechanically consolidated. Cast one (1) set of four (4) laboratory cured and one (1) set of four (4) field cured compressive strength cylinders form loads 3, 12 and 24. Curt Dawson (Meili Construction) was notified of on-site test results: Set 1 - I_"ad 3 Slump - 6" Concrete Temp. - 62F Air Temp. - 45F Air Content - 1.5% Set 3 - Load 24 Slump - 7" Concrete Temp. - 61F Air Temp. - 34F Air Content - 1.8% Set 2 - Load 12 Slump - 8" Concrete Temp. - 58F Air Temp. - 32F (Note: MBI representatives added plasticizer to each load on-site). To the best of our knowledge, the work inspected was in accordance with plans dated 08-30-06, PTC drawings dated 11-06 and applicable workmanship provisions of the I.B.C., except if noled above. Mr. Dawson was asked to notify our office when additional services are needed. Reviewed By: A,X.~ Michael L. Meyer Technical Manager c: Meiii Construction - Curt Meili (e-mail) Meiii Construction - Curt Dawson (e-mail) Bergsund Delaney Architecture & Pianning (e-mail) Hohbach-Lewin Structural Engineers (e-mail) City of Springfield MLM:jw This report and/or enclosed test data is the confidential property of the client to 'vVtlom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEt Testing & Inspection, lnc.'s written authorization. 750 IWJ CaneIJ A'Mlue . CavalJis, Qegrl97330 . pt01e (541) 757-4698 . fax (541) 757-2991 29540 B AiIpat Rood . Eugene, Qegrl 97402 . pt01e (541) 684-3849 . fax (541 )684-3851 ~