Geotechnical & Consb1.Jction Services
Daily Field Report
.1~'llllfl;"lf~~ll~IIIII(_
Client:
Project: The Royal Building
501 Main Street
Springfield, Oregon
Date:
Project No.:
Report No,:
Inspector:
ID No.:
Ms. Krislen Karie
St. Vincent de Paul
P.O. Box 24608
Eugene, Oregon 97402
12-28-06
2067145
E15010
E. Marjama
5235029
iCC
Inspection of: Reinforced Concrete
Contractor: Meiii Construction
Weather: Overcast
BP No,: COM2006-00624
Continuous Inspection: D
Periodic Inspection: 0
Performed final inspection on the reinforcing steel and PT tendons for the second floor
slab, lines A to G, from 1 to 6. Preliminary inspections were performed on 12-20-06
and 12-27-06 (ref.: FEI report no. E15031). Observed the placement of 270.0 cu./yds.
of MBI 5000 psi concrete (Mix 2450K050KS) in areas listed above. Concrete was
placed by pump and was mechanically consolidated. Cast one (1) set of four (4)
laboratory cured and one (1) set of four (4) field cured compressive strength cylinders
form loads 3, 12 and 24. Curt Dawson (Meili Construction) was notified of on-site test
results:
Set 1 - I_"ad 3
Slump - 6"
Concrete Temp. - 62F
Air Temp. - 45F
Air Content - 1.5%
Set 3 - Load 24
Slump - 7"
Concrete Temp. - 61F
Air Temp. - 34F
Air Content - 1.8%
Set 2 - Load 12
Slump - 8"
Concrete Temp. - 58F
Air Temp. - 32F
(Note: MBI representatives added plasticizer to each load on-site).
To the best of our knowledge, the work inspected was in accordance with plans dated
08-30-06, PTC drawings dated 11-06 and applicable workmanship provisions of the
I.B.C., except if noled above. Mr. Dawson was asked to notify our office when
additional services are needed.
Reviewed By:
A,X.~
Michael L. Meyer
Technical Manager
c: Meiii Construction - Curt Meili (e-mail)
Meiii Construction - Curt Dawson (e-mail)
Bergsund Delaney Architecture & Pianning (e-mail)
Hohbach-Lewin Structural Engineers (e-mail)
City of Springfield
MLM:jw
This report and/or enclosed test data is the confidential property of the client to 'vVtlom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclosed without FEt Testing & Inspection, lnc.'s written authorization.
750 IWJ CaneIJ A'Mlue . CavalJis, Qegrl97330 . pt01e (541) 757-4698 . fax (541) 757-2991
29540 B AiIpat Rood . Eugene, Qegrl 97402 . pt01e (541) 684-3849 . fax (541 )684-3851
~