CLIENT
.
.
/'
Geotechnical & Construction Services
Compressive Strength of Concrete
(ASTM C 39)
Ms. Kristen Karle
SI. Vincent de Paul
P.O. Box 24608
EUgene, Oregon 97402
DATE CAST
STRENGTH REQUIRED
STRENGTH PLACED
PRODUCT CODE
ADDITIVES
LOAD NO.
CONCRETE TEMP
AIR TEMP
POUR LOCATION
LOAD 24 SAMPLED
TEST
DATE
01-02-07
01-25-07
01-25-07
01-02-07
01-04-07
W/C
W/C
AGE AREA WEIGHT TOTAL COMPRESSIVE
(DAYS) (IN') (LBS) LOAD (LBS) STRENGTH (PSIl
5 LC 28.18 28.8 104000 3690
28 LC 2B.18 28.8 154300 5480
28 LC 28.18 29.0 155300 5510
Hold
5 FC 28.18 28.5 77000 2730
7 FC 28.09 28.7 98000 3490
PROJECT The Royal Buildin9
50> -5W1-Main Street
Sprin9field, Oregon
DATE
PROJECT NO.
REPORT NO.
01-25-07
2067145
4945
B.P.NO.
COM2006-00624
12-28-06 CAST BY
5000 psi
5000 psi SACKS
50-112 ES CEMENT
Eclipse, ADVA, Hot Water
24 TICKET NO.
610 F YARDAGE
340 F WEATHER
E. Ma~ama
DATE RECEIVED
SPECIMEN SIZE
SUPPLIER
MAX SIZE AGG.
AIR CONTENT
SLUMP
TIME
SPECIMEN STORAGE
2776377
240.0 OF
Overcast
270.0
Second floor PT deck slab.
Lines 5B.5.
AVERAGE
STRENGTH
(PSI)
TIME OF
TEST
8:05 AM
10:40 AM
10:45 AM
5495
8:10AM
8:20 AM
.. A. Cone B . ConelSplit C - Cone Shear D - Shear E - Columnar
REMARKS: Curt Oawson (Meili Construction) was advised of on-site test results.
Plasticizer added on-site.
LC - lab cure
FC - field cure
Reviewed By:
/11. ';(,~
Michael L. Mey/,!
Technical Manager
~
c: Meill Construction - Curt Meili (e-mail)
Meili Construction - Curt Dawson (e-mail)
Ber9sund Delaney Architecture & Plannin9 (e-mail)
Hohbach-Lewin Structural Engineers (e-mail)
MBI
City of Springfield
MLM:jw
12-29-06
6" x 12"
MBI
1 1/2"
1.8%
7"
12:15AM
4 cyls. ASTM C31
4 cyls. Field Cure
with blankets
TYPE OF
FRACTURE--
D
C
C
D
D
This report andlor enclosed test data is the confidential property of the client 10 whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclosed without FEI Testing & Inspection, lnc.'s written authorization.
7f/J rwv CorneD Avenue' Corvallis, Oregon 97330 . phone (541) 757-4698. fax (541) 757-2991
=SAirmrtRrm. F,,,.,,.,,,. 0n0rrn~741'1? r"IY1nAlf><!1\M4..'WlQ .r"ylf><!1\M4.."A~1