Client: Ms. Kristen Karle Project: The Royal Buiiding Date: 01-31-07
St. Vincent de Paul 501 Main Street Project No.: 2067145
P.O. Box 24608 Springfield, Oregon Report No.: E15248
Eugene, Oregon 97402 Inspector: A. Fenstermacher
10 No.: 5258882-49
Inspection of: Epoxy Dowels Weather: Clear Continuous Inspection: 0
Contractor: Meili Construction BP No.: COM2006-00624 Periodic Inspection: Ii'!
Performed continuous inspection during the installation of forty-six (46) #5 x 24" to 54"
vertical dowels into footing for extra reinforcement at corners for CMU wall. Prior to
installation, the predrilled holes were cleaned with a brush and compressed air.
Verified minimum embedment depth of 9". Dowels were secured using Simpson Set
22 (ICBO ES ER5279, expiration date 11-07). Note: holes were drilled using a 7/8"
diameter bit. Manufacturer's instructions state that a 3/4" diameter bit should be
used. Derrick (Meili Construction) was advised.
i\{
Changes to approved plans authorized by engineer: use of #5 epoxy anchored
vertical dowels verbally approved by engineer.
To the best of our knowledge, the work inspected was in accordance with engineer's
verbal instructions to Curt Dawson (Meiii Construction) and applicable workmanship
provisions of the I.B.C., except if noted above. Contractor was asked to notify our
office when additional services are needed:
Reviewed By:
;J; :(.!J"/J1--
Michael L. Mt{yer
Technical Manager
c: Meili Construction - Curt Meili (e-mail)
Meili Construction - Curt'Dawson (e-mail)
Bergsund Delaney Architecture & Planning (e-mail)
Hohbach-Lewin Structural Engineers (e-mail)
City of Springfield
MLM:jw
This report andlor enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process andlor material evaluated. As such, information contained herein shall not be reproduced in part or full andlor any part
thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization.
750 rwv CaneIIAvenue' Corvallis, Oregon 97330, phone (541 ) 757-4698, fax (541) 757-2991
29540 BAirpat Road . Eugene, Oregon 97402' phone (541 )684-3849' fax (541 )684-3851