Daily Field Report
Client: Ms. Kristen Karle Project: The Royal Building Date: 02-05-07
St. Vincent de Paul 501 Main Street Project No,: 2067145
P.O. Box 24608 Springfield, Oregon Report No.: E-15298
Eugene, Oregon 97402 Inspector: R. Marjama
10 No.: 5235029
Ins'pection of: Masonry Weather: Clear Continuous Inspection: 0
Contractor: Meili Construction BPNo.: COM2006-00624 Periodic Inspection: Ii!
Performed final inspection on the reinforcing steel for 8" CMU walls on line 1, from B to
G, on 2, from A to B, on A, from 2 to 6, on B, from 1 to 2, on 6, from A to G and around
column at A 1. Reinforcing steel was checked for grade, size, lap, placement and
clearance. Cells were relatively clean and free of excessive mortar projections. Walls
are currently 44" above top of stem walls, except at window openings where walls are
16" high. Observed the placement of 8.5 cu.lyds. of MBI 7 1/2 sack grout (Mix 712-G).
Grout was placed by pump and was mechanically consolidated. Grout slump 8"+; grout
temperature 63F; air temperature 53F.
~
To the best of our knowledge, the work inspected was in accordance with plans dated
06-29-06, revision dated 08-30-06 and applicable workmanship provisions of the I.B.C.,
except if noted above. Cory (Haps Masonry) was asked to notify our office when
additional services are needed.
Reviewed By:
/lJ.'-t,~---
Michael L. Me.;Z -
Technical Manager
c: Meili Construction - Curt Meili (e-mail)
Meili Construction - Curt Dawson (e-mail)
Bergsund Delaney Architecture & Planning (e-mail)
Hohbach-Lewin Structural Engineers (e"mail)
City of Springfield
MLMjw RECEIVED
FEe 1 2 Z007
This report andlor enclosed test data is the confidential property of the client to whom it is addressed and pertains 10 the specific
process andlor material evaluated. As such, information contained herein shall not be reproduced in part or full andlor any part
thereof be disclosed without FEI Testing & Inspection, lnc.'s written authorization.
750 rwv CaneI1 Avenue' Corvalis, Oregon 97330, phone (541 ) 757-4698, fax (541) 757-2991