HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-2-16
,,/'
.
.
{)fEI
Page 1 of 1
11~'IIIIIl;'U~'~:llllh'_
Geet....; II ~I & Construction Selvices
Daily Field Report
Client:
Ms, Kristen Karle
St. Vincent de Paul
P,O, Box 24608
Eugene, Oregon 97402
Project: The Royal Building
501 Main Street
Springfield, Oregon
Date:
Project No.:
Report No.:
Inspector:
10 No.:
02-16-07
2067145
E-15513
R. Marjama
5235029
Inspection of: Masonry
Contractor: Meili Construction
Weather: . Overcast
BP No,: COM2006-00624
Continuous Inspection: 0
Periodic Inspection: 0
Performed final inspection on the reinforcing steel for 8" CMU wall on line A, from 3 to
6, on 6, from A to G (11'8" to 14'0"), Reinforcing steel was checked for grade, size, lap,
placement and clearance, Cells were relatively clean and free of excessive mortar
projections, Observed the placement of 4,5 cu.lyds, of MBI 7 1/2 sack grout (Mix 712-
G), Grout was placed by pump and was mechanically consolidated, Three (3)
masonry prisms were constructed for compressive strength testing. Grout slump g"+
grout temperature 68F; air temperature 56F, Walls were grouted solid,
~
To the best of our knowledge, the work inspected was in accordance with plans dated
06-29-06, latest revision dated 08-30-06 and applicable workmanship provisions of the
I.B,C" except if noted above, Cory Reiling (Haps Masonry) was advised of on-site test
results and was asked to notify our office when additional services are needed,
Reviewed By:
!!e~1:?t--
Technical Manager
c: Meili Construction - Curt Meili (e-mail)
Meili Construction - Curt Dawson (e-mail)
Bergsund Delaney Architecture & Planning (e-mail)
Hohbach-Lewin Structural Engineers (e-mail)
./ City of Springfield
MLM:jw
This report andlor enclosed test data is the confidential property of the client 10 whom it is addressed and pertains to the specific
process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part
thereof be disclosed without FEl Testing & Inspection, lnc.'s written authorization.