Loading...
HomeMy WebLinkAboutPermit Building 2008-5-28 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2008-00310 ISSUED: OS/28/2008 APPLIED: 03/04/2008 EXPIRES: 11/2812008 VALUE: $ 1,904,658.00 SITE ADDRESS: 400 INTERNATIONAL WAY ASSESSOR'S PARCEL NO.: 1703154000500 SPRINGFIETYPE OF WORK: Office PROJECT DESCRIPTION: Building Shell Only Owner: HAWES INVESTMENTS LLC Address: 2892 CRESCENT AVE EUGENE OR 97408 Contractor Type Architect General Electrical Mechanical Plumbing TYPE OF USE: New Commercial Phone Number: 541-335-5594 .. I CONTRACTOR INFORMATION' Contractor ERIC HALL ARCHITECTS, INC. 1996 LLC BUILDERS ELECTRIC INC COMFORT FLOW TWIN RIVERS PLUMBING INC BUILDING INFORMATION' B M lIB # of Stories: Height of Structure Type of Heat: Water Type: Range Type: Energy Path: Sprinkled Building # of Units: Primary Occupancy Group: Secondary Occupancy Group: Primary Construction Type Secondary Construction Type: # of Bedrooms: Fljontyard Setback: Side 1 Setback: Side 2 Setback: Rearyard Setback: Solar Setbacks: Street Improvements: Storm Sewer Available: Special Instruction: Notes: License Expiration Date Phone 541-688-5594 541-687-9445 541-485-0922 541-726-0100 541-688-1444 114258 4296 460 17695 05/30/2011 12/10/2011 06/27/2009 03/11/2009 3 Lot Size: Sq Ft 1st Floor: Sq Ft 2nd Floor: Sq Ft Basement: Sq Ft Garage/Carport Sq Ft Other: Yes Occupant Load: 35,521 24,663 20,293 I DEVELOPMENT INFORMATION' Overlay Dist: # Street Trees Rqd: Paved Drive Rqd: % of Lot Coverage: AT u:NTlON: ~)1'v.JLh!tvn\llBftl(W~~S I follow Il'ules ad t/L..d L1 L1... B...tI-.. \3'l. Notification Center. Those rules are set forth In OAR 952-001-0010 through OAR 952-001.. 0090. You may obtain copies of tht rules b17 calling the center. (Note: the telephone number for the Oregon Utility Notification Center Is 1-800-332-2344). Page 1 of 4 REQUIRED PARKING Total: Handicapped: Compact: Sidewalk Type: Downspouts/Drains: NOTICE: THIS PERMIT SHALL EXPIRE IF THE WORK AUTHORIZED UNDER THIS PERMIT IS NOT COMMENCED OR IS ABANDONED FOR ANY 180 DAY PERIOD. Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Description Tvpe of Construction Bid Amount Use Bid Amount Fee Description Plan Review CommlIndlPublic + 10% Administrative Fee + 12% State Surcharge + 5% Technology Fee Building Permit Fire SF Fee - Non-Residential Plan Review Fire & Life Safety SDC Sanitary/Storm Admin Storm Drainage Impervious Area Total Amount Paid Initial Review SUB Review Plannine: Review Structural Review Fire Department Review Initial Review CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2008-00310 ISSUED: OS/2812008 APPLIED: 03/04/2008 EXPIRES: 11/28/2008 VALUE: $ 1,904,658.00 I Valuation Descriotion , $ Per Sq Ft or multiplier $1.00 Square Footage or Bid Amount 1,904,658.00 Total Value of Project ~ Amount Paid Date Paid $4,605.08 $1,513.24 $850.17 $354.24 $7,084.74 $8,047.70 $2,833.90 $679.88 $13,597.57 3/4/08 5/28/08 5/28/08 5/28/08 5/28/08 5/28/08 5/28/08 5/28/08 5/28/08 $39,566.52 I Plan Reviews I 03/05/2008 03/07/2008 APP LLH 03/07/2008 03/21/2008 APP DH 03/07/2008 03/24/2008 APP EMM 03/12/2008 04/01/2008 APP LLH 03/07/2008 04/10/2008 OK GRG 04/10/2008 04/10/2008 10 LLH Pae:e 2 of 4 Value Date Calculated $1,904,658.00 $1,904,658.00 03/07/2008 Receipt Number 1200800000000000199 2200800000000000770 2200800000000000770 2200800000000000770 2200800000000000770 2200800000000000770 2200800000000000770 2200800000000000770 2200800000000000770 Unable to enter structural review due to tag placed on parcel by planning for annexation agreement. Addressing fee collected with foundation permit. Pass energy code review. See attached documents. Plans reviewed by Mick Nolte with the Building Department under contract with the City of Springfield See attached document for Fire Department Plans Review comments. Deferred submittal required for class II hood and exhaust CITY OF SPRINGFIELD. Building/Combination Permit PERMIT NO: COM2008-00310 ISSUED: OS/28/2008 APPLIED: 03/0412008 EXPIRES: 11/2812008 VALUE: $ 1,904,658.00 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Initial Review 04/11/2008 04/11/2008 10 LLH Initial Review 04/18/2008 04/18/2008 APP LLH Public Works Review 04/18/2008 04/18/2008 APP JHJ Plannin2 Review 04/18/2008 04/22/2008 APP EMM Structural Review 04/18/2008 04/25/2008 APP LLH Public Works Review 03/07/2008 05/01/2008 APP JHJ Fire Department Review OS/25/2008 OS/25/2008 APP GRG Faxed special inspection form and deferred submittal form to Eric Hall. Addendum to shell currently under review. Attached revised SDC worksheet. Addendum to shell currently under review. To be constructed per approved Final Site Plan DRC2007-00060. Addendum to shell currently under review. Reviewed by Mick Nolte with the Building Department under contract with the City of Springfield Attached revised SDC Worksheet. (JHJ) Plans Review: revised submittal of Hawes building project~building shell only (Package B). Job #COM2008-00310. Occupancy Classifications: A-2, A-3, B, M. Construction Type: II-B sprinklered. Square footages: 1st floor: 35,521 sq. ft.; 2nd floor: 24,663 sq. ft.; 3rd floor: 22,177 sq. ft.; Total: 78,174 sq. ft. Revised submittal changes do not affect original fire plans review comments dated 4/10/08. Refer to original submittal for fire plans review comments. To Request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following work day. [..ReouireCUnsnections . Framing Inspection: Prior to cover and after all rough in inspections have been approved. Roof Sheathing Firewall: Located and constructed according to plans. Pa2e 3 of 4 CITY OF SPRINGFIELD - Building/Combination Permit Status Issued PERMIT NO: COM2008-00310 ISSUED: OS/28/2008 APPLIED: 03/04/2008 EXPIRES: 11/28/2008 VALUE: $ 1,904,658.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541- 726-3 769 Inspection Line Masonry: Bolts Installed in Concrete: To be done by a State Certified Special Inspector. Provide inspection test reports to City Building Inspector. Structural Concrete: In excess of 2500 psi. To be done during construction by a State Certified Inspector. Provide results to City Buiding Inspector Hold Downs Installed: Special Inspection performed prior to placement of concrete. Provide report to City Building Inspector. Epoxy Anchors: To be done by Certified Spcial Inspector. Provide Inspection results to City Building Inspector. High Strength Bolting: To be done during construction by a State Certified Special Inspector. Provide inspection results to City Building Inspector. Special Inspection: Weld Inspection: To be done during construction by a State Certified Special Inspector with approval from the City of Springfield. Copies of inspection results shall be provided to the City of Springfield. Special Inspection: High Strength Bolting Inspection: To be done during construction by a State Certified Special Inspector with approval from the City of Springfield. Copies of inspection results shall be provided to the City of Springfield. Special Inspection: Moment Resisting Steel Frames Inspection: To be done during construction by a State Certified Special Inspector with approval from the City of Springfield. Copies of inspection results shall be provided to the City of Springfield. Special Inspection: Masonry, Mortar, Grout, and Reinforcing Steel Certificates Inspection: To be done during construction by a State Certified Special Inspector with approval from the City of Springfield. Copies of inspection results shall be provided to the City of Springfield. Final Building: After all required inspections have been requested and approved and the building is complete. SUB Insulation Vapor Barrier: To be called for at the same time as the SUB framing inspection. SUB Final: After all required energy inspections have been requested and approved. SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover. SUB Ceiling Grid: Interior Lighting SUB Exterior Lighting By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. ~/?,~ It) g< Date Paee 4 of 4 225 Fifth Street Springfield, Oregon 97477 541-726-3759 Phone City of Springfield Official Receipt Development Services Department Public Works Department Job/Journal Number COM2008-00310 COM2008-00310 COM2008-00310 COM2008-00310 COM2008-00310 COM2008-00310 COM2008-00310 COM2008-00310 Payments: Type of Payment Check cRecemtl RECEIPT #: 2200800000000000770 Date: OS/28/2008 DeSCrIptIOn Plan ReView FIre & LIfe Safety FIre SF Fee - Non-ReSidential BUlldmg Permit + 5% Technology Fee + 12% State Surcharge + 10% Admmlstratlve Fee Storm Dramage ImpervIOus Area SDC Samtary/Storm Admm Paid By HA WES INVESTMENTS LLC Item Total: Check Number AuthorIzatIOn ReceIVed By Batch Number Number How Received DJB 3034 In Person Payment Total: Page 1 of 1 1:53:36PM Amount Due 2,833 90 8,04770 7,08474 35424 850 17 1,513.24 13,597 57 679 88 $34,961.44 Amount Paid $34,96144 $34,961.44 5/28/2008