Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2002-1-28 Jan-29-02 02:06P Mortier Eng & Building D (541)484-6859 P.02 '245 PEARL STREET EUGENE, OREGON 97401 PHONE (54') 484-9080. FAX (54') 484.6859 TOLL FREE IN OREGON '.877-66'-9959 \."'1 U. T / ;:. . ~~~.;,"'J~'~:~"'JI <'r.: .~ ~~.., 'I" .I ~ -Ii ~~.~ I_III . I' i~"" 'I I ; :i;.t.. '~:. .' ~ . (.',J11b J~I;...J....,-, <I.,' .; ','I;~,,!,,;0.~""";- .."r IN); \:\'- 'c. ,.' lot91Q ~ Ul MORTIER 'ENGINEERING, EC. STRUCTURAL BUILDING DESIGN . FIRE PROTECTION CODE CONSULTANT' PLAN CHECKING CONSTRUCTION INSPECTION January 28, 2002 Cozy Homes 1275 2nd Street Spnngfield, Oregon 97477 RE' 1.~'ot~'1'1ri,1.'11', ai:i~ 1,1'2leYI"Landjn.~ Sprirl'gflelq: ~e:SO.lIS Invest,g~foh>,,~'o. # 14265-~DRl As you requested, a site/soils investigation was performed on these three adjacent Jots on January 18, 2002. Design for the site IS as follows:' All unsUitable fill, vegetation. and un buildable matenal have been removed. The natIve SOil is a silty- clay loam with a Unified Soils Classification of Ml and a plasticity Index of less than 15, The expansiveness of the SOil IS low (after Holtz 1959) A maximum 4" of crushed rock should be Installed with tracked excavation equipment to protect the proposed bUilding site In the event of inclement weather No extraordinary drainage or compaction IS required for treatment of expansive soils at this site. ' On January 29, 2002, a compaction inspection was preformed after fill placement on lot 110, The compacted surface of the 1 W' minus crushed rock IS adequate for a foundatron bearing capacity of 1500 psf, With the exceptIon of the area south of rear garage foundation, ThiS area had been driven on by a loaded dump truck causing the sub grade to intermix with the crushed rock This IS crawl area where indiVidual footIngs are to be installed to support the 32" on center floor beams. The contractor was Instructed to hand excavate to firm bearing and then place the concrete for the IndIVidual pads in the excavated holes There are 12 pier locations where thiS needs to be preformed and when accomplished, the site Will be adequate to support the proposed conventIonal wood framed residence. Thank you for thiS opportunity to be of service, The enclosed BUilding AnalYSIS Report and Statement of CondItions is a part of this report If you have any questions regarding this report, please e at 484-9080 ~~~o O/-'~rS' ~G\N~ .fft ~ 19094PE 1> i. 4/ OREGO ~ <9"?1."'~'" 1 5 I .. g~~ 1/ 'OLey R, ~ /7. ~ 1- /ExpIres: J z./J VI ~ Bradley Myers, P.E. .