Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2002-11-7 NOV-7-c~~~ 10:54P FROM: TO: 15419889571 P:l/l 8lo~ b, Cct1*'-sr ~ORD ~ NESS ~ ::ASS 3:\J:)~: Z, ''JC. LANDSURVEYINC . CONSTRUCTION SUPERVI~ION . WATER RIGHTS lXAMINATIONS CIVIL FNGINEERING . GEOTECHNI("AL . lNVlRONMENTAI November 7,2002 Grassroots Development 1135 Cat Young Road ,;Eugene, Oregon 97401 RE: Aggregate Compaction Evaluation Louis McClain Lot 43 - South Hills North Subdivision Springfield, Oregon On November 5, 2002 representatives from Ford~Ness-Fassbender, Inc. VISited the subject site to assess the bUilding pad conditIons with respect to the relative compaction of the aggregate cover. SIte testing of the %"-0 crushed aggregate from Spnngfield Quarry indicates that the thickness of aggregate ranges from 6-inches up to 3-feet in the northeast portion of the site. The aggregate has been compacted to at least 95% of the matenals maximum dry density of 133.5 pet ilS determined by AASHTO T -99 method. The subgrade and aggregate fill are suitable for conventional residential style perimeter footing construction We recommend that all footings be remforced With at least two #4 steel reinforcing bars, and that surface water be directed away from the foundations and not allowed to pond adjacent to footing. Installation of upslope footing drains IS recommended and should be oullet to a proper point of dIspOSal, and sUlface dramage should be routed around the building pad. We do not recommend allowing dump-trucks, concrete- trucks or other heavy equipment onto the building pad during wet weather Sincerely, Ford-Ness-Fassbender Inc. ,~~. ,F'. Ronald J. Derrick, Fl.E. o 116 Hwy. 'Jlj N ,SOlte 100. r.o. Box 22 735. ~Ulll.:nC, OR 9/402. (~41) 144-1852. fall (541) J44-!:l913 [-mall mall@tl\finr npj .Wl!b ~11I.: www fnfm," Mt CPft,t)prl W H ~ I D B E