March 20. 2002 D V "
r vr-:v I'it.;:,;:, r H;:,;:,tlt.HUI:..I'(
P. 2.../Z - ---.----
P:l"l
John and Jennirer t"\\l!)bard
c/o Grassroots Oevelopment
~ 136 eel Young Road
Eugene, Oregon 97401
RE.: Aggregate. Compaction Evaluation
L:.ot 48,- McKenlie Hills Subdivision
Tax Lot 4700
r N. 72nd'
Eugene, Oregon
On MarCh 18. 2002 a field density test was perfanned en the abOve referenced residential
building lot tc assess compaction of the approJClmately 4- to e.lnch thick layer of *'.0 crushed
aggregate placed over the sUbgrads. The aggregate was compacted using a ~ibratory plate
compactor and a weight to volume calculation was performed on a drive sample of the
aggregate. The compaction of the aggregats was determined to be at least 95% of tne
aggregatas maximum dry density of 133.5 pet as determined by AASHTO Method T.ge. The
subgrade and compacted fin on this lot is suitable for conventional residential ~Of'lStructian.
I
I
We recomlT!end the landseape soil slope to direel surface water sway from aU ,foundations, and
water should nor pond adjacent to footings. Due to the potential for near surface seepage, a
fOoting drain, consisting at 3-incf'l diameter perforated pipe encased in 1 cubicifcat pet foot of
drain rock wrapped with filter fabnc be install@o ICSjacenl to all up slope footings,
Sil'1cerely I i
ford-Nsss-Fassbender Inc. I
~.,_.,
~ '>RO"'t~
.c~~
~ ~ 16,110 W'
~'''~~ ~
~OREeo~~
Ronald J. Oerrick, P.E. ~r..... ".~'"
~JI.,l~1 ~
~O J. ~~ '" l:a oJ;'. tiS
"6 "'WY,99N.,hi\e 10011'.0. 8oll:11n$IUUIl!I\C. 019740111 (S41) 344~'"S2aFlllll!4') )44,~'H
E-mall;."4lII..nflne.net _ Web sile; www.fllfinc.nel
CerriGed WB,f./ D,I F.