HomeMy WebLinkAboutPermit Field Test & Inspection Report 2002-9-4 -FROM FAX NO. Sep. 0S 2002 02:22PM Pi MORTIER ENGINEERING1 ~C~ 124:' PEARL STRECT EUGENE. OReGON 97.101 PHONE (541) 484-9080. FAX (;~1) 484-6859 -rOLL FREE IN OREGON 1-877-661.'3959 ~ ~. ld\-ln St- \ct\5 STRUCTURAL BUILDING OESIGN · FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION September 4, 2002 Adam & Sarah Salene 257 16th 51. Springfield, OR 97477 RE: Lot 2 South HIlls Subdivision. Sorinafield:" Rim Joist Fix. W.O.#14591 -QPM This letter IS In regards to the upper floor 9 %~ T JI PRO 250 joists which were placed short of the nm board by approximately 1 %". The fix for this is to add a joist or rim board 1 %" wide at the top and bOttom to fill the space between the end of the joists and the outer rim board. The joists are to have a minimum bearing of 1 %". Thank you for thiS opportunity to be of service. If you have questions r~garding this report, please contact me at 484-9080. l0~e - ,.t; "1 ( HI '!:r.... ~, l~ TAQL Bradley R. Myers, P.E.