September 4, 2002
Adam & Sarah Salene
257 16th 51.
Springfield, OR 97477
RE: Lot 2 South HIlls Subdivision. Sorinafield:" Rim Joist Fix. W.O.#14591 -QPM
This letter IS In regards to the upper floor 9 %~ T JI PRO 250 joists which were placed short of the
nm board by approximately 1 %". The fix for this is to add a joist or rim board 1 %" wide at the
top and bOttom to fill the space between the end of the joists and the outer rim board. The joists
are to have a minimum bearing of 1 %".
Thank you for thiS opportunity to be of service. If you have questions r~garding this report,
please contact me at 484-9080.
l0~e -
,.t; "1 (
HI '!:r....
~, l~
TAQL
Bradley R. Myers, P.E.