DAILY FIELD REPORT
Project Name:
Ambleside SubdivIsion - 1 st Add
Project Location:
Springfield, Oregon
P.O. No.:
Type of Inspection:
Permit No.:
Weather:
N/A
Clear
Field Observations and Comments
PSI representative observed excavation of organrcs contaminated SOil along lot line boundary between south faCing lots
on Ambleslde Drive and north faCing lots on Falcon Drive BUried grass strlpplngs and bUried rooted grass were
exposed and removed between lots 94 through 1 02 In general, bUried fresher grass was encountered from 0 to 2 feet
below eXisting ground elevation With more decomposed grass from approximately 5 to 2 feet below that The lateral
extent of these layers to the south (towards Ambleslde Drive) was determined, as per Mr Glenn Ling's (project
engineer) Instruction by excavating five lateral trenches south of the lot line excavation based on the observed cross
section In these trenches, the southern extent of these layers was defined and painted at the ground surface
/'
Clean, stripped subgrade elevation was measured at three locations Within the lot line excavation, they are as follows
1) ApproXimately 95 feet south of lot 100 & 101 boundary on Falcon Drive - 487 80, 2) ApprOXimately 134 feet south of
Falcon Drive approximately 487 80, 3) ApprOXimately 95 feet south of lot 97 & 98 boundary plus 20 feet (to the east) on
Falcon Drive approximately 482 60
Inspector: Mike Dewey
If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649
Respectfully Submitted,
If. J( tLli;at1tu 6J)
Raymond V Allpertl, CS Dept Manager
Springfield Branch
cLing & ASSOCiates - Mr Glenn Ling