HomeMy WebLinkAboutPermit Field Test & Inspection Report 2008-5-16 "v. L...1 V, .. LI I ... K & A Engineering, Inc. 3327 Roanoke Ave., Eugene, OR 97408 (541) 684-9399 Voice (541) 684-9358 FAX engineering May 16, 2008 Project: 151.06 Hayden Enterprises, Inc. 2464 SW Glacier Drive # 110 Redmond, OR 97756 Subject: S -II-) Jasper Meadows subdlvlslon--Lot 235 - 16-20 - ,S 7 Springfield, OR Foundation Soils PURPOSE AND SCOPE At your request, K & A Englneenng, Inc_ has completed a geotechnical investigation of the eXisting salls on the subject property. Our understanding IS that a wood-framed single-family residence supported by a cast-in- place concrete spread footing foundation is proposed for construction on this site. The purpose of our investigation was to determine the sUitability of the soils for construction of the proposed structure, and provide recommendatIons for construction of the foundation. The scope of our services IS limited to general surtablhty with respect to beanng capacity and expanSive salls FOUNDATION PAD PREPARATION The project site IS located on the west side of South 5J1h Place on a residential lot In the new" Jasper Meadows" subdlvlslon_ The lot IS mostly level and there are no apparent slope movement hazards The anginal ground surface is low lying and IS poorly drained. Based on the foundation pad excavation, soils consist of approximately 1.5 to 2.5-feet of dark brown, wet, loose, organic silt, over gray, wet, moderately stiff, plastIC clay with some areas mixed with weathered and decomposed sandstone. FoundatIOn preparation Involved constructing a level foundation pad on a subgrade conSIsting of native undisturbed Salls ThiS required excavating and removing approximately 1_5 to 2.5-feet of dark brown organic SIlt from the foundation pad area After the excavatIOn and removal of the unsuitable soils, approximately 3 to 4- feet of 3-inch minus Silty sandy gravel with angular gravels up to 3-inches was placed over the subgrade and compacted with a vibratory steel drum roller. Approximately 6-inches of %-inch minus dense graded crushed aggregate was then placed, graded, and compacted on the foundation pad. This served to provide a uniform surface for footing construction at the deSired elevation The fill matenals were placed and then compacted uSing a VIbratory steel drum relleL We tested the m-place density of the o/4-inch mmus dense graded crushed aggregate fill and have determmed that the average dry denSity exceeds 95-percent of maximum as determmed by ASTM D698 The field test results are attached to thiS report. K & A Engineering, Inc. SUMMARY AND RECOMMENDATIONS The project s~e, as prepared, is sUitable to support the proposed foundations. We recommend a design allowable bearing capacity of 2,OOO-pounds per square foot. The soils present a moderate shrink/swell hazard Foundation loads should bear on undisturbed native si~s a mInimum depth of 36-inches below final grade around the penmeter foundation The prepared foundation pad meets these recommendations. Final grading around the foundation pad should raise the grade above the foundation using native or imported silts and should slope away from the foundation. We recommend approval of the foundation pad, as constructed, bV the building official. Thank you for the opportunity to be of service. Please call us If you have Questions or need further assistance. Respectfully, Steve Schultz, E.I T. K & A Englneenng, Inc r>>>RES Ijr if~~/F Client: Hayden Enterprises Jasper Meadows-Lot 235, Springfield, OR Project: 151 06 Page 2 of 2 May i 6, 2008 I~ 0 L'J 0 I ~ 4/ I '... Density of Soil and Soil-Aggregates In-Place ASTM 02922 and 03017 Project: '151.06 Site Address: Jasper Meadows--Lot 235 Permit No: Date: 5/16/2008 Density TestType1: DT-6 Operator: SS Material Type: 3/4" (-) from Springfield Quarry Maximum Dry Denstly, pet 1280 StandardizatIOn and Reference Check.1 Density (Sfandard Deviations) (S.D.) 006 .(\ Moisture. (S.D:) 109 Moist Density, Compaction, Test No. pef % Remarks 1 1389 993% 2 142.6 103.1% 3 I 1296 122.7 5.6 95.9% I I r - I I I I ~ Average 99.4% Std. Dev.: 3 59% 1 Direct TransmissIon (DT) (specify depth. in.) or AIr Gap Backscatter (AGS) (speclfly(T)ouchable or (U)ntouchable mode Test performed usmg Seaman Nuclear Corp model C-300, SN 21113 Client: Hayden Enterprises. Inc Project: 151.06 K & A Engineering, Inc. 5/16/2008