HomeMy WebLinkAboutPermit Correspondence 2004-10-5 O~_t.~q.S-04 lO:37A MOr.r Eng & Bu;ld;ng 0 (S_>484-68S9 P.02 1245 PEARL STREET EUGENE, OREGON 97401 PHONE (541) 484-9080. FAX (541) 484-6859 TOLL FREE l.an-661-9959 /~i~'f //" .i~"m:'2-i~:~::' 't~. ;C..,J!, "1' " " ".', '. ~~t,:_ ""'; ',.<:~!:I:;<:..'~'.&>;~I.....:-::.~ ." \'I.:",~.,\.." ',('1.\'1. \.,\\...,. ',~ ..:....,,~.,..~ ..... STRUCTURAL BUILDING DESIGN. FIRE PROTECTION CODE CONSULTANT' PLAN CHECKING CONSTRUCTION INSPECTION MORTIER ENGINEERING. P.C. October 5, 2004 Midway Manor 1625 Himderson Rd. Springfield, OR 97478 RE: 1625 Henderson Rd. - Revision To Engineering - W.O. #16118 As requested, the engineering dated 8/4/04 has been revised. The revisions are as follows: 1. Cross ventilation is required to be installed at the roof. A minimum area of 12 square . inches is required at 48"0.c. around the perimeter of the building. At the vaulted area, 1 JI," diameter holes are to be placed at the top of the rafters, 12" from the rafter support. Where the rafter span is less than 48", one 1 Yz" diameter hole is to be placed at mid span, at the top of the rafter. The ventilation is not required to continue through the glu lam beams. Thank you for this opportunity to be of service. If you have questions regarding this report, please contact me at 484-9080. Sincerely, ~~. (1,,1 .... ~~~\'''''~~ . ~t(,:<t\". \'t\.\~\i> ~ ,~~).~." Bradley R. Myers, P.E.