HomeMy WebLinkAboutPermit Fire Department Referral 1986-6-30 ~ .>:, ....,' ~' " ,":':~>' , e. SPRINGFIELD ,.,. liU:l OF SPRINGFTF.T.n Fire Prevention Bureau Building Division '. 30 June 1986 Connie Filkins/Classic Burger 495 Harlow Road Springfield, Oregon 97477 ,'I" , Subject:. Fire Department referral at 495 Harlow Road Springfield, Oregon .~ Dear Ms Filkins: At the request of the Springfield Fire and Life Safety Department,' the Building Safet)" Division recently conducted an inspection at the above address. The inspection revealed the following conditions which must be corrected in order for the building to comply with applicable City Codes. The following items must be repaired, replaced, installed or modified: ", ., Structural Specialty Code and Fire and Life Safety Code 1. The upstairs attic space is being used for storage of combustible materials without adequate wall and ceiling fire protection, in violation of Section 11.207 of the Uniform Fire Code. 2. The attic office exits through the storage .room, and these. rooms exit through the kitchen area, in violation of Section 3303(e) of the Structural Specialty Code (SSC). Approved, fire protected exitways are required for exiting through these areas. 3. The A. B. C. attic stairway is insufficient in the following ways: Stairway width is less than the required 36 inches (SSC 3306(b)). Stair risers exceed the maximum allowable height(SSC. 3306(C)). Required handrails are missing (SSC 3306(j)). ..,. 4. The exposed, flammable paper facing on the attic insulation is unprotected. The Structural Specialty Code requires such facings to be protected by direct contact with approved surface materials, such as gypsum board (SSC 1713). ,I.. " .... ','-:0, 5. The upstairs office area lacks required ventilation for habitation (SSC 705). "":.' I ,. .:~; . The above deficiencies must be eliminated within the next 30 days py either discontinuing the uses causing the cited violations, or modifications"} must be made to the existing building which will allow for the proper use of the structure, including adequate fire protection. If this option is selected, plans must be submitted and permits obtained from this office before any modifications to the structure begin. . . 225 North 5th Street · Springfield. Oregon 97477 · 5031726.3753.5031726.3737 ~.',,;'J ~ "!. r" e , Connie Filkins/Classic Burger 30 June 198(; Page 2 If we can be of assistance in clarifying the requirements, or the options available to bring the building into compliance, please call us at 726-3759. 7a:lH~ Don Moore Structural Inspector . cc. Dave Puent, Building Official Mike Hudman, Fire Marshal .' Jon L. Sullivan/Robert R. Hamilton P.O. Box 52, Springfield, Oregon 97477 ~. . ". .'. -..<...,. RETURN TO . ..... . PENALTY FOR PRIVATE \:;. USE. aDO CITY OF SPRINGFIELD DEPARTMENT OF PUBLIC WORKS . - ~ . .---.\ .... -................. (N~60ndW)11 ""11' -.J."..._. SPRINGFIELD, ~REGON 97477 CNo. end Street, Apt.. Suite. P.O. Box or R.O. No.l (City, Stato.end ZI' COda' I ~--. ill . SENDER: Compl'" ;,.....,. 2. 3 ancI4. ." o Put your addresa In the "RETURN TO" apace on the 3 revene side. Failure to do thit will prevent this cMd from W being returned to you. The r4tft,lrn retolnt 1'_ yrill P!ovlde ~ "",ou the neme of tM n....(\n dellwered te" and the date of ~ deU",!I!Y. For additional f... i:he1'otlowing tefV~" a~ ", available. Consult postmaster fo,. f.. and check bOlIIIl..) for senicetl} r8QU_ted. ': l!' ~ i w ,. g Show to whom. date and oddreu ot'deUve,.y. 2. 0 Restricted c;;;lv.rV:" ~ :""'-' 3. ~. I l:l ..~ CI Article Addras.d to: Connie Filkins/Classic C!i9S:HarJ;;W-Roall..3 Springfield, QR 97477 Burger 4. Type of Service: Article Number o Registered .g Certified o Expreu Mail o Insured o COO . P 329 963 980 Alway, obtain signature 01 &ddressee.2Lagent and DATE DELIVERED. o ~ m In ... 'n " m ... C " Z " m n m ::;; ... 5. Sip"Jatur. - Addr.... X r-~ n{1IO/Y\~ ~ 6. Signature - AgeM ........ - ... f}~ X 7. Date at o.livery e. Add'_'~~~'~ (~Nl~;~..,t4 ond /tt />lid)