Loading...
HomeMy WebLinkAboutPermit Correspondence 1982-4-15 ---:-'" . .' SPRINGFIELD lilU OF SPRINGFIELD Department of Public Works April 15, 1982 Sherwood & Roberts Inc. 1335 S.W. Fifth Avenue P.O. Box 1309 Portland, Oregon 97207 RE: Final Inspections at 7025 Glacier, Springfield, Oregon 97477 ,/ Dear Si r: At your request the Building Division of the City of Springfield conducted the final inspections on the structure located at the above referenced address. The following items shall be installed, repaired or completed before a Certificate of Occupancy will be issued: Oreqan Structural Svecialtl.( Code crnd Fire crnd Life Safetl! (S.S.C.) 1. The rise of every step in the front entrance stairway shall be not less than 4 inches nor greater than 8 inches. S.S.C. 3305 ,2. The plywood under the front bedroom window soffit shall be properly secured. S.S.C. Table 25-0 3. Access to the garage area shall be made available for the final ,inspection. S.S.C. 305 (b) 4. Adequate drainage has not been provided for moisture protection of the dwelling unit at the front patio door sills. The deck covering and installation of the covering is not what was orginally approved at the time of the permit issuance and was done without proper authorization. S.S.C. 303 (a) 5. Street trees shall be planted at not less than 30 feet on center. S.S.C. 307 (c) Oreqon Electrical Svecailtu Safetu Code (E.S.S.C.) The receptacle outlet located under the dining room window is not properly grounded. E.S.S.C. 210-7 Oreqon Mechanical SveciaU", Code crnd Fire crnd Life Safet", (M.S.C.) The range vent is to be not less than No. 26 galvanized sheet gage steel which is made substantially airtight and shall terminate directly to the outside atmosphere in an approved vent cap. M.S.C. 1901 225 North 5th Street . Springfield. Oregon 97477 · 503/726-3753 .......-;r '. . Sherwood & Roberts Inc. 1335 S.W. Fifth Avenue RE: Final Inspections at 7025 Glacier, Springfield, Oregon 97477 April 15, 1982 Page 2. ,. OPeqon State PLumbinq SPeciaLty Code (P.S.C.) 1. The roof leaders shall connect to the rain water drain pipe at a point not less than '10 inches above grade and convey water to the outside of street curb. The drainage lines shall be flushed of accumulated debris before inspection. /' P.S.C. 1405 2. The dishwasher drain shall discharge into the disposal unit. A directional type fitting may be used when a disposal unit is not available. P.S.C. 310 3. The outside hose bibbs shall be secured to'the siding with a minimum of two wood screws. P.S.C. 316 (c-2) 'Please direct all inquiries to the Springfield Building Department at 726-3753. Sincerely, O~: "'Y. ~ \- ,Dave Puent Building Inspector , DP Ish