Loading...
HomeMy WebLinkAboutPermit Mechanical 2002-8-16 . . cP' Page 1 of4 TRANS#:01-0010321 DATE:AUG 16 2002 AMT RECD:2 $ 100.05 CHANGE: CASHIER:061 I Job# 02-00455-01 I . 225 Fifth Street Springfield, OR 97477 CITY OF SPRINGFIELD, OREGON PUBLIC PERMIT City Of Springfield Community Services Division Building Safety Job Number: 02-00455-01 Office: 726-3759 Inspection Line: 726-3769 Location Of Proposed Site: 1300 Hayden Bridge Rd Spr Assessors Map#: 17032522 Lot: Block: Addition: Owner: Address: Tax Lot #: 00800 Subdivision: Springfield Public Schools 525 Mill Street Phone Number: 541-744-6375 City/StatelZip: Springfield, OR 97477 Value: $642,807 Scope Of Work: Mechanical Elizabeth Page Elementary School 24 geothermal heat pump units w/ catwalks & support frames. Contractor Type Electrical Contr Engineer Mechanical Contr Plumbing Contr Alteration ~\- Contractor Registration ~,\~~E~~ir'a't1~n,Date ~v ,..n\\ - _\ ,\V~ ~ Scofield Electric Co 38702 \~~\0 0\e12tg1/2~Op)\ , Po Box 2765, Eugene, OR 97 402-0307 0~0"" ,\\.....13, ~0'" 0'....~ '?J'O ,,,e'iJ '0 J .0\ 0'0, 0\Y' or \Y 0 Hatten/Johnson Associates ,,\O~' 00~\0 ~.....os OY>~"'" 0,.;s.0 R.....O~\\O.... 223 West 12th Avenue, Eugene,.0~~ ~e"''l1' ....\0\. \O.;s.~ 0~\0'" ~0'10\0 ~\c'l> 97401 \'-~\~O~ \~O"" ~~O",O~\i\"" ~O\~~\\~ ~~,. EMK Mechanicallnc ~ .,'~\C~ ,,';;,13&.463 '0\.1:i 0....8/23/2003 \C)' ",'" ....'-'....' Q; ~"v 4290 West 11th Street. Suite A~Euglne~oY> ~0 c0 0\0 ~OO' OR 97402 \\' ,,'?JO. .....~"I. ~.;s.0 ,.",'" , O'V ~\, ~('O e' \ EMK Mechanicallnc C ~~1'36t63'\! 8/23/2003 4290 West 11th Street, Suite A, Eugen~ OR 97402 Phone 541-686-8612 541-343-8748 541-683-3715 541-683-3715 ~~~ ~~ ~ 'iJ'\ . 'f'\ - ,c" ~ Office Use . ~'jSl'\'-~~~~~ ~~~ Quad Area: 2PNC Land Use: Elementary ~001\\ S~~~~f,'&.'~ # Of Units: . Zoning Code: LDR ~~'\'I. ~~~' \) \J~\O~f)~ncy Group: School 50+ Constr. Type: Bedrooms: ,\y,'S \l ~,1..S \) \)'FJ~t'Source: Water Heater: Range: \>..\J'\~~I\~~\:':~ l$ij:'Footage: I'D'" ~ 'O\) v To request an inspection call the 24 hour recording at 726-3769, All i~spections requested before 7:00 a,m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following working day, Footing Framing Structural Welds Final Fire Final Building Required Inspections I Buildinq -After trenches are excavated. - Prior to cover. - To be done during construction by State Certified Special Inspector, Provide inspection test res -When all Fire Department requirements have been met. -When all required inspections have been approved and the building is complete, . Rough Electrical Electrical Service Final Electrical Underground Plumbing Sanitary Sewer Line Backflow Device Rough Mechanical Final Mechanical . . I Job# 02-00455-01 I Required Inspections Electrical Page 2 of 4 - Prior to cover, - Must be approved to obtain permanent power, -When all electrical work is complete. I Plumbing - Prior to filling the trench, - Prior to filling trench. -After device is installed but before backfilling trench. Mechanical - Prior to cover. - When all mechanical work is complete, Zoning: LDR FloodPlain? 0 Wetlands? 0 Journal numbers 1: 2: Comments: Planner: Urban Growth Boundary?D Quantity Of Fill: Supplier: Drainage: Floodway FEMA: Overlay District: # of Street Trees: Land Use: Elementary School Pave Driveway? 0 3: Additional Requirements: Glenwood Area? 0 Required Attachments: Source Locn: Material: Construction Types: Occupancy Groups: School 50+ # Of Buildings: # Of Bedrooms: Handicap Access? 0 rArea (Sq. F~,,) Main: Accessory: Fee Public Plan Review Adjusted Public Plan Review Total Plan Check Building Permit State Surcharge For Building Permit State Surcharge For Building Permit 8% Building Administrative Fee 8% Building Administrative Fee Total Building Minimum Electrical Permit Fee Permanent: 200 Amps or Less Flood Plain FEMA: # Of Stories: Current Units: Census Code: Does not apply Height (feet): Proposed Units: Total: Paid On Receipt# Plan Check 04/25/2002 8724 05/24/2002 9228 Value/Quantity Fee Amount 450,000 408 $1,107,05 $407,71 $1,514.76 Buildin!! 06/06/2002 9419 OS/24/2002 9228 06/06/2002 9419 OS/24/2002 9228 06/06/2002 9419 642,807 $2,330.40 $,00 $163.13 $,00 $186.43 $2,679.96 Electrical 08/02/2002 10158 08/02/2002 10158 3 $,00 $189,00 . Fee Branch Circuits With Feeder or Service State Surcharge - Electrical 8% Admin Fee - Electrical Total Electrical Minimum Plumbing Permit Fee Minimum Plumbing Permit Fee Number of Fixtures State Surcharge - Plumbing State Surcharge - Plumbing State Surcharge - Plumbing Sanitary Sewer Footage Backflow Prevention Device 8% Administrative Fee - Plumbing 8% Administrative Fee - Plumbing 8% Administrative Fee - Plumbing Total Plumbing Minimum Mechanical Permit 8% Administrative Fee - Mechanical 8% Administrative Fee - Mechanical 3hp - - 100,000 BTU Alter/Add to ea Appl Unit or System Equipment Not Itemized on Permit Mechanical Issuance State Surcharge - Mechanical State Surcharge - Mechanical Total Mechanical Photocopy Fees Total Deposit/Copies/Mis Grand Total Plan Check Type Checked By Initial Review-C/l/P Engineering-C/IIP Planning-C/IIP Structural-C/I/P Lisa Hopper Pam Ownby Liz Miller Don Moore Fire Marshal-C/l/P AI Gerard Job# 02~0455~1 . Page 3 of 4 Paid On Receipt# Value/Quantity Fee Amount Electrical 08/02/2002 10158 31 $93,00 08/02/2002 10158 $19.74 08/0212002 10158 $22,56 $324.30 Plumbinll 06/06/2002 9419 $31,00 08/16/2002 10321 $,00 08/16/2002 10321 3 $42,00 05/24/2002 9228 $,00 06/06/2002 9419 $3,15 08/16/2002 10321 $6,09 08/16/2002 10321 30 $45,00 06/06/2002 9419 1 $14,00 05/24/2002 9228 $,00 06/06/2002 9419 $3.60 08/16/2002 10321 $6,96 $151.80 Mechanical 06/06/2002 9419 $,00 OS/24/2002 9228 $,00 06/06/2002 9419 $26,16 06/06/2002 9419 24 $288,00 06/06/2002 9419 1 $30,00 06/06/2002 9419 1 $9,00 06/06/2002 9419 $10.00 OS/24/2002 9228 $,00 06/06/2002 9419 $22,89 $386.05 Deposit/Copies/Mis 06/06/2002 9419 9 $4,75 $4.75 $5,061.62 Date Completed Comment 04/22/2002 05/03/2002 0412312002 04/29/2002 Changing heating system to geothermal heat pumps from hot water radiators. Geothermal system to collect ground water from new water well and inject back into aquafer through separate infustion well. Existing boiler to remain operalionalto serve kitchen and restorooms and possibly to provide backup for heat pumps, 4/26/02 Received engineering for connection of HV AC rackson top of walls. Added 2"x2"x1/4" washers to underside of wall plates. OK dim Not required to be reviewed by the fire depl. 04/30/2002 . Job# 02-00455-01 . Plan Check Type Checked By Date Completed SUB - Comm/lnd Jack Foster 05/06/2002 SUB - Commllnd Don Moore 04/26/2002 . Page 4 of 4 Comment Pass energy code review Faxed compliance forms 3b & 5b with documentation to Jack Foster from the architect. dim By signature, I state and agree that I have carefully examined the completed application and do hereby certify that all information herein is true and correct, and I further certify that any and all work performed shall e done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Or on. I further state that only contractors and employees who are in compliance with ORS 701.055 ill be used on this project. I further agree to ensure that all required inspections are request!lJl a the proper time and that the project address is readable from the street. --~ ' Sig~Ure- B -/~ -'(}'2- Date