Loading...
HomeMy WebLinkAboutPermit Building 1997-11-24 ,) SPRINOFIELD Page 1 COMMERCIAL/INDUSTRIAL PERMIT APPLICATION CITY OF SPRINGFIELD Job Number: 971006 COMMUNITY SERVICES DIVISION BUILDING SAFETY 225 North Fifth Street Springfield, OR 97477 Office: 726-3759 Inspection Line: 726-3769 Location of Proposed Work: 1011 HARLOW RD Assessors Map #: 17032200 Tax Lot #: 02503 Owner: PACIFIC CONTINENTAL Address: 111 WEST 7TH Phone #: 686-8685 City/State/Zip: EUGENE, OREGON 97401 Description Of Work: BANK & TENANT SPACE NEW Value: 0.00 Name Architect: GLAS ARCHITECTS Address REID ANDERSON Phone 686-2014 --- PLUMBING --- No. 57 Fee Charge 570.00 55.00 55.00 190.00 55.00 20.00 Single Fixture Sanitary Sewer Water Service Storm Sewer 226' FIRE LINE 2 BACKFLOW DEVICES 170 216 1084 ft. ft./; ~ ~.~ ~ C 0, U'..<> ~ ~ ~ 1a ~ .' ~~~~ ~~~~ ~~~"?y :t-o-Q ~ ~ ~\. MEC~cAfl J,.., '~ ~ -1~ ~ ~Fee 1000, 000 'BTU~ ~ ~ ~~~~ <::>~ ~ ~ ~~rr 945.00 TOTAL PERMIT 3 Furnace/burner & vent < Vent Fan/Single Duct 7 CONDENSOR UNITS 3 VENT SYSTEMS 6 GAS OUTLETS Permit Issuance Charge 60.00 , 9.00 42.00 13.50 3.00 10.00 No. TOTAL PERMIT 137.50 HANDICAP ACCESS: Y - - OFFICE USE QUAD AREA: 1CNW LAND USE: 5300 Item Sq. Ftg Main PARKKING GARAGE CANOPY Square Feet 36461 12880 1118 x $/Square Feet Value 2,464,107.00 0.00 0.00 TOTAL VALUE OF PROJECT 2,464,107.00 . , SPRINOFIELD Job Number: 971006 Page 2 Plan Check Fee: 1,880.45 Rec #: 26444 Date: 07/01/97 Rec By: DON MOORE BUILDING Surcharge/Admin MECHANICAL Surcharge/Admin PAVING VALUE PLUMBING Surcharge/Admin SIDEWALK CURBCUT ADDITIONAL PLAN REV. CITY SDC FEES 385,180.00 4,280.50 342.45 137.50 10.21 1,076.50 945.00 75.60 46.60 18.10 901.88 121,632.20 7,l8'.y. :1" J,;l.9 , 4 H 540 SUBTOTAL PERMITS TOTAL PERMIT FEES EXCLUDING ELECTRICAL 129,466.54 REQUIRED INSPECTIONS It is the responsibility of the permit holder to see that all inspections are made at the proper time. To request an inspection, call 726-3769 (recorder), state your City designated job number, job address, type of inspection requested and when you will be ready for inspection. Requests received before 7:00 a.m. will be made the same working day, requests made after 7:00 a.m will be made the following work day. Special Inspections: In accordance with a special inspector shall be employed by construction of any following "*11 work. shall be furnished to Building Safety. Section 306 of the State Specialty Code the Owner/Contractor during A copy of the special testing reports In addition to the inspections specified, the Building Official may make or require other inspections of any construction work to ensure compliance with the Building, City or Development Code. GRADING/EXCAVATING/FILLING - To be done during constr by Special State Certified Inspector. Provide reports/tests to City Building Inspector UNDERGROUND PLUMBING - Prior to filling trench. TEMPORARY POWER UNDERGROUND ELECTRICAL - Prior to Cover. FOOTING - After trenches are excavated. FOUNDATION - After forms are erected but prior to concrete placement. SLAB - To be made after all inslab building service equipment, conduit piping, and other equipment items are in place but prior to concrete BOLTS INSTALLED IN CONCRETE - To be done by State Certified Special Inspector. Provide inspection/test reports to City Building Inspector STRUCTURAL CONCRETE in excess of 2500 psi. To be done during constr. by State Cert. Insp. Results to City Building Inspector MASONRY - Steel location, bond beams grouting or verticals in accordance with UBC 2415. STRUCTURAL MASONRY - To be done during constr by State Certified Special Inspector. Provide results to City Building Inspector. HIGH STRENGTH BOLTING - To be done during constr by State Certified' Special Inspector. Results provided to City Building Division. SPRINGFIELD Job Number: 971006 Page 3 STRUCTURAL WELDS - To be done during constr by State Cert Special Inspector. Results of inspection/test to City Building Inspector. SPRAYED ON FIREPROOFING - To be done during constr by State Cert Spec Inspector. Provide reports/tests to City Building Inspector. ROUGH PLUMBING - Prior to cover. ROUGH MECHANICAL - Prior to cover. ROUGH GAS - after line is installed and capped if not attached to an appliance ROUGH ELECTRICAL - Prior to cover. ELECTRICAL SERVICE - Must be approved to obtain permanent power. FRAMING - Prior to cover. INSULATION - Floor; prior to decking Wall/Ceiling; Prior to cover INSUL-V.B./SUB: TO BE CALLED FOR AT SAME TIME AS SUB FRAMING INSPECT DRYWALL - Prior to taping. CEILING GRID FINAL PLUMBING - When all plumbing work is complete. FINAL GAS - When all gas work is complete. GAS SERVICE - After line is installed and line has been connected to a minimum of one appliance. Pressure test done at this point. FINAL MECHANICAL - When all mechanical work is complete. FINAL ELECTRICAL - When all electrical work is complete. FINAL BUILDING - When all required inspections have been approved and the building is complete. - - - ADDITIONAL COMMENTS - -- DRC 96-12-256, PLANNER IS JIM DONOVAN SITE REVIEW JOURNAL #96-12-256, JIM DONOVAN, PLANNER ADDITIONAL FINAL INSPECTIONS REQUIRED WHICH WOULD NOT FIT: FINAL SUB, FINAL FIRE DEPARTMENT, SITE PLAN FINAL, SIDEWALK, CURBCUT. Plans Reviewed By: LORNE PLEGER Date: 09/03/97 Building Site Reviewed By: LISA HOPPER By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that project address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. J~AM I/~ Signature / 11-24.77 Date --- VALIDATION --- Receipt Number: Date Paid: \ \- 9.., L\ 0./, Amount Received: , Received By: ", . . JOB NO. 'TI/~k')'? AIT ACHr~ENT A CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE WORKSHEET /. NAME OR COt1PAN'/: .2~/'..h1,;. &,,J7'n~~1.lJ:- LOCATION: /0;/ 4".h0/!d OEVELOPMENT TYPE Aj~'LA/ ih-n. jL:. / of/!., c..e ,$Ii BUILOING SIZE 1.~7XJ fe;eJ.-.j/~\ OT SIZE fb .6,;; / STORH ORArHAGF LtbYt~-~Y _ ' 1. p'if hN/~'f'e.IY~ :;.-1.:1: LI 1I1PERIf [aUS SO. FT, . ("' '"f. ,36/ X $0.226 PER SO. FT. SO. Ft. NO. OF PFU'S ;:<)~ (See Reverse Side) ^ $J6.86 PER PFU ~'~\ 0-' / $ '-1 I( ~ i//2b/f7 1,() O~"',-l /I.j d..l," ~J.: <;.- ~6l"i :lJ1J8lW . Sf? f., $ 7 1& p~ / , 2. SMITT;lPY Sr:',,JER-CITY 3. TRANSPORT.U,nON - ~e?\rd,-,-kd :;i-I~ NO OF UNITS X TRIP RATE X COST PER TRIP f}v.f. PrAt,-'f '" S-Y x;<O 'X $472.49 fy;f. wvJ/~-l.lt,,, &3 oJ;"'t-e/~f3,33 ~y.P-J . 4. SANiTARY SFWFR.MWMC NO. OF FEU'S .15,7 X~EpER FlU + $10 ~IWMC/ADM FEE.$ 7',91703:: .:,-'7 ~.~.15/- J il!-2.ft!97 TOTA(-MWMr snc ,q;9:f~ ~'2 ~\W /9 ' l/L497L/c)- X ,.J- ,l1/' X $472. 49 87 $,-,>, /0.1- ,30 $~1) '77'0 - 8k '}..19 qf3 3 ". X 17,'15 X $472 119 MWMC CREDIT IF APPLICABLE (SEE REVERSE) SUBTOTAL (ADD ITEMS 1.2.3 & 4) 5. ADMINISTRATIVE FFFS BASE CHARGE (SUBTOTAL ABOVE) X .05 of. $ .J :~ h~ 4(~~ /I SDc( Co6Cdi na tor ' Date: /;ho/'3>) '. -""'- TOTAL snc $ a IGd;1 ;;/z. ,,17-7 - 7/.,\') (l1j6-'~',')--':; I'd . ".'.1;".(.;,/ .'J3r.."{,.'.'J- ,c.j..,k,..rC'cl