HomeMy WebLinkAboutPermit Building 1989-4-5
.. RESIOE..NTlAL"
APPLICA./PERMIT
225 North 5th Street
SpringfieZd, Oregon 97477
BuiZding Division
726-3753
/,.J.tt'-l ;+",,-,J.jo..J. S (~.."'< ~,<Ic!
( '7- 6 3- ~ d) d- ;:,= Lot ~ on;bl ()
La+-# ~ lO~J'~ .~.~.~'
~-f,.,-,- (3, /.1,,,-,~
Job Location:
ABOeSGOl'Z Map #
Subdivision:
Q.mel':
AddPess: J 7 'i.J... ~~.,/.) s-I-
City:
e..~.....~, tfl.....~..--
"
.
i
! Cll.mo,
I n lid"
! A t.t1.on
n Remodel
n Hobile Homa
Data of Apptiaaticn
Contl'actOl'B
Genera I r-...J w . (!,
P!wnbina C .....<- ofo~ PI.." b,.<I<
Electrical J~ ~k.- .
/J.char.ic~Ii?Q {~..T ;[",,/'':-c
.J
Constl"'Uction Lender . .-'-_ A J. 'IJ L
,? I.u /J 'i
Phone: ~- '/.YS 3i7fo
zip:
f7Vo I
Rcco'ipt !I
/3r:J IS-
<;,'
~ '\'~,
DescPibe fl'Ol'k:
:s ,=- fZ
i~q.s~-
-
Value ,f,-8' nil 0
.'
" .\:
{!c, if - s- -C( I
Siqr.ed: R. ~
Date: 3 /~F/~'i
Address Lise. # Expires Phonc
, lfJ- C..,,~ t: 0.(. < 31.'-I'fy &Irr<; 1.,1 /; C.?I7.1o
<"<JI'''i'I''~' ~ .Jon ~I ID/d <; ?VI 175 ("
""'03 1)\.1 ~.J.. lid L(,- ~n3{O 7/6'1 9>1L - ~ (., 7 l-
3S10 If! /'lit. e~( .}ol."~ jJ'o 7YI . OO~ L
It is the responoibility of the permit holder to see that all iru;pections are made at the proper tim€~ tr.at Daoh .::.ddress is roadao:e
fl"Ol11 the streot~ and that the permit oaro is 'Located at the front of the property.
ABui!di!'lg Dividor: approt-'ed plan sJu:.Zl remain on tho; Bu::.Zding Sits at a1.Z. times,
PROCEDURE FOR INSPECTION RE:aUEST:CAlL 726-3769 (recorder) state your City designated job nw::ber~ job add:t>css~ type of in.:;pec:icI:
requested ar:d when you wiLl be ready for ir.spcction~ Contractors or Owner's ncme and phone number. Requ&sts receit:ed oeforo 7:00 c::':
:..>ill be made the same day~ requests made afta' 7:00 a:n will ba made the nczt :lJOrking day.
Jl'9 Od-47 ,
Reaui~ed InSDp.cticns
O SITE INSPECTION: To be m:zde after
e:.ccavation~ but prior to set up of
fo1"ms.
O UNDERS[,AB PWUBING. E[,ECTRIC,1[, &
MECHANICAL: To be made before any
work is covered.
1 !ZJ
FOOTING ~ FOUND,ITION: To be made
after trenches are excavated and
fo1'rrls are erected~ but priol'" to
pouring ccncrete.
UNDERGROUND PLUMBING, SEWER. W.4TER.
DRAINAGE: To be TrKlde prior to fil-
lir.g trenches.
~
o
o
UNDERFWOR PWf.1BING & UECHANICA[,:
To be made prior to in:;talZation of
f1aor insulation or decking.
POST AND BEAM: To be ",mie proior to
installation of floor insl.4lation or
dscki"li .
ROUCH P~W.!BIlJC. ELECTRICAL & MECH-
ANICAL: No work is to be cOt-'ered
ur.ti l thcse inspections have beer.
made and approved.
FIREPLACE: Prior to pZacir.g facing
materials and before framing inspec-
tior..
FRA1:INC: Must be requested after
approval. of rough p'Lurrbing~ alectroi-
ool & mechan~al. An roofing
bracing & chimnCYB~ eto:!. TrrJ.st be
. completed. No work is to be con-
~ cealed until thia inspection has
~ bs~ made and approved.
[2]
[2]
]2J
Your City Deoigr4tcd Job Number 10:
I "'I"NSU[,ATTONIVAPOR BARRIER INSPECTION,
,/ To be TMde after all. insulati::m ar.d
.. required vapor barriers are in place
. . but befol"e any lath~ gypsum board or
wll coveroing is app7.ied~ and before
any inauZati.on is concealed.
DRYWALL INSPECTION: Tc be made
after all drywa7.7. is in pZace~
but prior to any taping.
MASONRY: Steel Zocation~ bond
beamG~ grouting or verticals in
acco1"dance with U.B.C. Section
2415.
D WOODSTOVE..: After installation is
ccmpl.ted.
[K]
o
[2]
CURB & APPROACH APRON: AfteI' forms
are erected but prior to pouring
ooncrete.
SIDEWALK & DRIt'EWAY: For all con-
crete paving within street right-
o f-way ~ to be made after a l Z. exca-
vating canpZete & form wrk & t:ub-
.base materia~. i~ pla~e.
DEMOLITION OR ;~;OVED BUILDIjiGS
:=J Sani tary seuer capped ::::t p:..opcrtj. lir:e
~ Septic tank p'.i.,?cd and fil7.e~ lJith ~:;6Z.
::J Final - fl'hen above ite.-ns are ccrrrpletcd
and when demolition is complete or 8tru~-
ture moved ani premises cleaned up.
Nobile Hcmes
~
D
PENCE: WheT: complete -- Provide
gates or movable sections through
P.U.E.
=:J Blocking a1Ui Set-up
=:J Plumbing connections -- S~6r ar-d wa:6r
--, Electrical Conn.ection - Blocking ~ set-u?
~ and plumbing connections nr~st ce appro~oc
before requesting BZec:rical inspec~io~
:=J Acces:::o1"";:i Building
---, Final - After p~rcr.es~ skirting~ deckn~
~ etc. are completed.
o
All project conditions~ such as the installation of street tr6eB~ ca~lation of t~e
required Zandscapir:g~ ctc.~ must be satisfiad before the BUILDINC FINAL can be raquest~d.
FINAL BUILDING: The Final Building Inspection ~t be requested altor the Final Plumbi"{J
Elcctl'ical~ and Mechar:ical Inspectio1W have been made and approvad.
:Kl FIIIA[' PWMBIIIG
:ZJ FIIIA[' I1E~HANICA['
::EJ FINA[' EU;CT,uCA[,
=:J
@
D
~ALL MANHOLES AND CLEANOUTS HUST BE ACCESSIBLE. ADJUST!fEl'IT TO BE /.!'1DE AT /.'0 C:J5T TO CITY I PaFc 1 of ::
_.~.',~'::."~"'.":'\~:-''''~',,'~''''...;'' _.--.- -.-. ......
. .-_.-.".. .~ '-.' . .
I JOB NO, f90;"Y'l
I Zona: ~~
Lot Sq. Ftg. ~,??'
.
i of lot Coverag< ::?o-~=
#, of Stories t
TotaL Height /~ _ .r;; /
Topography ", . 2.. ~
lITEM
I Main
Garaae
Carport
ACCeS801'U
L-COG~
SOLAR ACCESS REQ,-
OCCUDanC" Gro4I,..f'- '3 9/77-/
WT TYPE ( wt Faces - ?;.vTH '
I Set~cks
, P. L. I Hou.se I earage Access.
INorth '5<9,$'7 I
lEast I /<"? / I
IS<mth I 12='
If,est I? 7/1 I
I SQ.FTG I
1/~!5.2""",
I.1;"JU,7~1
I I
I I
I I
TOTAL VAWE
(vaLue)
1.5 x
1 NO., FEE
21
1/1
II I
~#'/~'d'
I~'; FEE
III I
131'3',""'1
I ri..L.__ ~d"" 13flk I
r~';"6:-;'? Vc;;;.-.?i I ' I
I
I ::? y. so
I /. ':<3 I
1'A;).731,
I
I
I
f
I
,
Is.D.G.
Building Permit
State Surcharge
Total Char-gos
lITEM
I Fi:r:tures
lid'
I Res entw.l
(J bath)
i Sanitary SeweY'
I Water
I 7rP;i?/,?
Plumbing Perd. t
State SU1'cr.arge
Total CharGes
I ITEM
Res. So.
fto. /'16'3
New/Extend Circuits
I .
I TempoI'ary Sel'V'Lce
I -;:;:: Q;>,4 5i!'/9 y~
Ele~trical Permit
State SurCMrqe
Total Charces
ITEM
Furnace ETU' S
E:::haust Hood
Vent Fan
Permi t Issuance
Mechanical Permit
State SurcharGe
7'01;1"11_ r.harrum
II;'
I
1/ I
II I
I -- ENCROACHMENT --
Ise~uPit~ DeOo3it
! Storage
I Main tenanee
I Pcrmit
Total Char>ocs
Curbcu~
In ?'7 1
b'.G
Sid_Zk
Fen:::e
7''/'4F #-
Electtical Label
Mobile Home
TOTAL AMOUNT DUE: >t
FEE
...K
InteriOr>
C01'nel'
Panhandle
Cul-de-sac
x
I
I
~
I
I
I I
I ;;-s.. .:::<::>0.-:
I 2> ?C?, ..... ,
I -:::?o 7. ""'"
/5. ;?~
I ?':<'2.?s1'
I CHARGE i
157-,)..<'>
I
I
I
I
I
I
Value
:;>':::::>.-
/' s-: ..:--
2:C}. """"
It??' 5<::>
.c;.3&
//2,$
I
I 3"7- ~
I
I
I
I /~, <>&>
J '-/. 5'.DJ
I -:79'-.5'::>"
I
I
I
":7. ~ I
2---=1
7- ---~ I
CHARGE
IS.=---
;? ?,,;5><>
CHARCE
th ' .><>
'7-- 5' d>
/3'.((;0
/9.90
,/1 rll ()
'-t'?J t~ ~d1 . '26
I
I
I
i?' /V 57./6
(.~ Bed:rooms: 2-
J I Ene1'Gu SOU1'ces
I I Heat ~
I I Watel" Ht?atp.p ..,
I I Range ~ez-r- .
I I Fipeplacc
I I WOod3tove
II
TU'Oe
'I';''Pe/Const:
r'./t.
Fees
I
,~
, ,
.1
Building Value
&
Permit
This permit is granted on the expY'ess condition that the sdid aonstruction
shall, in all 1'espccts, confoPm to the OY'dinance adopted by the city of
Springfield, incZuding the Zoning ordinance, regulating the conDt~u~ticn
and use of buildings, and m~y be suspended 01' 1'evokec at any time upon vio-
lation of any provisions of said Ordinances.
Plan Check Fee: /9 ?, S-!7"
g -.;;J ?- fr' '1
Rec<<pt #: /3 't'c"eP
!Signed: ,4~.? ~//_.
, - ~
Plumbing Permit
Date Paid:
No person shall construct, instalZ, alter or change any new 01' e=isting
plumbing or drainage system in whole or in part, unless such person is the
legal possessor of a valid plumbcY"s license, except tr~t a pe~son may do
plur.:bing lJJOY'k to propepty which is olJned, leased 01' operated by the appli-
cant.
,
Electrical
Permit
Where State Law requires tr4t the electrical work be done by an Ele~trical
Contractor, the electrical poption of this permit shall not be valid untiZ
the Zabel has been signed by the ElectricaZ Contractor.
Mechanical
Permit
4~h?-V~~~
"prExc:m1-neY' - ~
y- -;5'-&9
uat:e
I HAVE CAREFULLY EXAM.INED the compZeted appliaation for pe1"11lit, and do
hereby certify that all ir.fo~.ation hereon is tru.e and coppcct, ani I
further certify that any ar.d all woY'k peY'formed shall be dO:'le in ac~or-
dance :Jith the Ordin:::maes of the City of Springfield, and th~ La'..;s of the
* State of OregQn p8rtaining to the work descl"ibcd herein, end tha~ NO OCCU-
PANCY wiZZ be rrnde of any st1'UctUl'e without peI'mission of the Buildin.g Di-
vision. I fupther certify that only contY'aetoY's ~-~ ~lQyees who are in
c~pliance with ORS 701.05~ will be used on this project
I
I
I
I
I
L_
rJ? ~
.3 j.L<f J&- 7
Signzd
Date
..J